Inverter based distributed generator islanding detection method using U/O voltage relay

Islanded operation of distributed generators is a problem that can take place when they are connected to a distribution system. In this paper an islanding detection method is presented for inverter based distributed generation (DG) using under/over voltage relay. The method is an adaptive one and is...

Full description

Bibliographic Details
Main Authors: J. Sadeh, E. Kamyab
Format: Article
Language:English
Published: Iran University of Science and Technology 2012-12-01
Series:Iranian Journal of Electrical and Electronic Engineering
Subjects:
Online Access:http://ijeee.iust.ac.ir/browse.php?a_code=A-10-863-1&slc_lang=en&sid=1
id doaj-23fd7dc1d1654b5683ac2275bc6dd6e9
record_format Article
spelling doaj-23fd7dc1d1654b5683ac2275bc6dd6e92020-11-24T22:01:45ZengIran University of Science and TechnologyIranian Journal of Electrical and Electronic Engineering1735-28272383-38902012-12-0184311321Inverter based distributed generator islanding detection method using U/O voltage relayJ. Sadeh0E. Kamyab1 Electrical Engineering Department, Faculty of Engineering, Ferdowsi University of Mashhad, P.O. Box: 91775-1111, Mashhad, Iran. Tel./Fax: (98) 511 8763302 Faculty of Engineering, Ferdowsi University of Mashhad, P.O. Box: 91775-1111, Mashhad, Iran. Islanded operation of distributed generators is a problem that can take place when they are connected to a distribution system. In this paper an islanding detection method is presented for inverter based distributed generation (DG) using under/over voltage relay. The method is an adaptive one and is based on the change of DG active power reference (Pref) in inverter control interface. The active power reference has a fixed value in normal condition, whereas, if the point of common coupling (PCC) voltage changes, Pref has determined as a linear function of voltage. The slope of Pref is dependent to the load active power (Pload) and should be changed if Pload changes. The non-detection zone (NDZ) of the proposed method is dependent on the accuracy of the voltage measurement equipment if changing of the PCC voltage is sensed, then, islanding will be detected if it is occurred. Also it does not have any negative effects on the distribution system in normal conditions. Moreover, the proposed technique can be applied when two-DG is in the island. The proposed method is evaluated according to the requirements of the IEEE 1547 and UL 1741 standards, using PSCAD/EMTDC software.http://ijeee.iust.ac.ir/browse.php?a_code=A-10-863-1&slc_lang=en&sid=1Adaptive islanding detection Inverter based distributed generation Non detection zone Under -Over voltage relay
collection DOAJ
language English
format Article
sources DOAJ
author J. Sadeh
E. Kamyab
spellingShingle J. Sadeh
E. Kamyab
Inverter based distributed generator islanding detection method using U/O voltage relay
Iranian Journal of Electrical and Electronic Engineering
Adaptive islanding detection
Inverter based distributed generation
Non detection zone
Under -Over voltage relay
author_facet J. Sadeh
E. Kamyab
author_sort J. Sadeh
title Inverter based distributed generator islanding detection method using U/O voltage relay
title_short Inverter based distributed generator islanding detection method using U/O voltage relay
title_full Inverter based distributed generator islanding detection method using U/O voltage relay
title_fullStr Inverter based distributed generator islanding detection method using U/O voltage relay
title_full_unstemmed Inverter based distributed generator islanding detection method using U/O voltage relay
title_sort inverter based distributed generator islanding detection method using u/o voltage relay
publisher Iran University of Science and Technology
series Iranian Journal of Electrical and Electronic Engineering
issn 1735-2827
2383-3890
publishDate 2012-12-01
description Islanded operation of distributed generators is a problem that can take place when they are connected to a distribution system. In this paper an islanding detection method is presented for inverter based distributed generation (DG) using under/over voltage relay. The method is an adaptive one and is based on the change of DG active power reference (Pref) in inverter control interface. The active power reference has a fixed value in normal condition, whereas, if the point of common coupling (PCC) voltage changes, Pref has determined as a linear function of voltage. The slope of Pref is dependent to the load active power (Pload) and should be changed if Pload changes. The non-detection zone (NDZ) of the proposed method is dependent on the accuracy of the voltage measurement equipment if changing of the PCC voltage is sensed, then, islanding will be detected if it is occurred. Also it does not have any negative effects on the distribution system in normal conditions. Moreover, the proposed technique can be applied when two-DG is in the island. The proposed method is evaluated according to the requirements of the IEEE 1547 and UL 1741 standards, using PSCAD/EMTDC software.
topic Adaptive islanding detection
Inverter based distributed generation
Non detection zone
Under -Over voltage relay
url http://ijeee.iust.ac.ir/browse.php?a_code=A-10-863-1&slc_lang=en&sid=1
work_keys_str_mv AT jsadeh inverterbaseddistributedgeneratorislandingdetectionmethodusinguovoltagerelay
AT ekamyab inverterbaseddistributedgeneratorislandingdetectionmethodusinguovoltagerelay
_version_ 1725838662678085632