Breakdown Voltage Characteristic Of Mineral Oil In Power Transformer 16 Mva Updl Semarang

The transformer is one of the most important equipment in the electric power system, which is to distribute power from power plants to the load centers by step-up or step down the voltage. Transformer is expect to have a high level of reliability. One of the causes of damage to the power transfor...

Full description

Bibliographic Details
Main Authors: Setyo Adi Nugroho, Setyo Aji Priambodo
Format: Article
Language:English
Published: Universitas Muhammadiyah Purwokerto 2020-11-01
Series:Techno
Subjects:
Online Access:http://jurnalnasional.ump.ac.id/index.php/Techno/article/view/7957/3604
id doaj-2440bbe3a02d4c38bfb02977858f1217
record_format Article
spelling doaj-2440bbe3a02d4c38bfb02977858f12172020-11-25T04:11:11ZengUniversitas Muhammadiyah PurwokertoTechno1410-86072579-90962020-11-0121211912410.30595/techno.v21i2.7957Breakdown Voltage Characteristic Of Mineral Oil In Power Transformer 16 Mva Updl SemarangSetyo Adi Nugroho0Setyo Aji Priambodo1Diponegoro University, Semarang-IndonesiaGadjah Mada University, Yogyakarta-IndonesiaThe transformer is one of the most important equipment in the electric power system, which is to distribute power from power plants to the load centers by step-up or step down the voltage. Transformer is expect to have a high level of reliability. One of the causes of damage to the power transformer is its insulation system. Mineral oil is an insulator that is widely used in power transformers. One of the important parameters in oil type insulation is the breakdown voltage value, the greater breakdown voltage value, as better the insulation quality. In this research, a breakdown voltage test is carried out on a Shell Diala B transformer oil type regarding the IEC 60156-95 standard. The results showed a breakdown voltage in the power transformer oil at UPDL Semarang of 49.2 kV. These results have met the feasibility standard of transformer oil, based on the IEC standard the value of breakdown voltage of liquid type insulation is 30 kV.http://jurnalnasional.ump.ac.id/index.php/Techno/article/view/7957/3604transformerinsulationbreakdown voltage
collection DOAJ
language English
format Article
sources DOAJ
author Setyo Adi Nugroho
Setyo Aji Priambodo
spellingShingle Setyo Adi Nugroho
Setyo Aji Priambodo
Breakdown Voltage Characteristic Of Mineral Oil In Power Transformer 16 Mva Updl Semarang
Techno
transformer
insulation
breakdown voltage
author_facet Setyo Adi Nugroho
Setyo Aji Priambodo
author_sort Setyo Adi Nugroho
title Breakdown Voltage Characteristic Of Mineral Oil In Power Transformer 16 Mva Updl Semarang
title_short Breakdown Voltage Characteristic Of Mineral Oil In Power Transformer 16 Mva Updl Semarang
title_full Breakdown Voltage Characteristic Of Mineral Oil In Power Transformer 16 Mva Updl Semarang
title_fullStr Breakdown Voltage Characteristic Of Mineral Oil In Power Transformer 16 Mva Updl Semarang
title_full_unstemmed Breakdown Voltage Characteristic Of Mineral Oil In Power Transformer 16 Mva Updl Semarang
title_sort breakdown voltage characteristic of mineral oil in power transformer 16 mva updl semarang
publisher Universitas Muhammadiyah Purwokerto
series Techno
issn 1410-8607
2579-9096
publishDate 2020-11-01
description The transformer is one of the most important equipment in the electric power system, which is to distribute power from power plants to the load centers by step-up or step down the voltage. Transformer is expect to have a high level of reliability. One of the causes of damage to the power transformer is its insulation system. Mineral oil is an insulator that is widely used in power transformers. One of the important parameters in oil type insulation is the breakdown voltage value, the greater breakdown voltage value, as better the insulation quality. In this research, a breakdown voltage test is carried out on a Shell Diala B transformer oil type regarding the IEC 60156-95 standard. The results showed a breakdown voltage in the power transformer oil at UPDL Semarang of 49.2 kV. These results have met the feasibility standard of transformer oil, based on the IEC standard the value of breakdown voltage of liquid type insulation is 30 kV.
topic transformer
insulation
breakdown voltage
url http://jurnalnasional.ump.ac.id/index.php/Techno/article/view/7957/3604
work_keys_str_mv AT setyoadinugroho breakdownvoltagecharacteristicofmineraloilinpowertransformer16mvaupdlsemarang
AT setyoajipriambodo breakdownvoltagecharacteristicofmineraloilinpowertransformer16mvaupdlsemarang
_version_ 1724418550116909056