Winding Hottest-Spot Temperature Analysis in Dry-Type Transformer Using Numerical Simulation

A thermal analysis of a 5 kVA dry-type transformer under linear and non-linear loads conditions is studied in this paper. The main goal here is to calculate the hottest-spot transformer temperature under free convection through the resolution of the heat conduction equation in three dimensions (3D)...

Full description

Bibliographic Details
Main Authors: Rafael Gonçalves Mafra, Elisan dos Santos Magalhães, Bruno de Campos Salles Anselmo, Fernando Nunes Belchior, Sandro Metrevelle Marcondes Lima e Silva
Format: Article
Language:English
Published: MDPI AG 2018-12-01
Series:Energies
Subjects:
Online Access:http://www.mdpi.com/1996-1073/12/1/68

Similar Items