Summary: | Purpose: Treatment of irreducible femoral intertrochanteric fractures often requires open reduction. However, the technique unavoidably causes patients to suffer greater trauma. As such, minimally invasive techniques should be employed to reduce the surgical-related trauma on these patients and maintain a stable reduction of the fractures. Herein, a minimally invasive wire introducer was designed and used for the treatment of femoral intertrochanteric fractures. The effectiveness of using a wire-guided device to treat irreducible femoral intertrochanteric fractures was evaluated. Methods: Between 2013 and 2018, patients with femoral intertrochanteric fractures who were initially treated by intramedullary nail fixation but had difficult reduction using the traction beds were retrospectively reviewed. Decision for an additional surgery was based on the displacement of the fracture. The patients were then divided into two groups: those in the control group received an open reduction surgery while those in the observation group received a closed reduction surgery using a minimally invasive wire introducer to guide the wire that could assist in fracture reduction. The operation time, blood loss, visual analogue scale scores, angulation, reduction, neck-shaft angle, re-displacement, limb length discrepancy, and union time were then recorded and analyzed to determine the efficiency of the wire introducer technique. Categorical variables were analyzed by using Chi-square test, while continuous variables by independent t-test and the Mann-Whitney test accordingly. Results: There were 92 patients included in this study: 61 in the control group and 31 in the observation group. There were no significant differences in baseline demographic factors between the two groups. All surgeries were successful with no deaths within the perioperative period. The average follow-up time for the patients was 23.8 months. However, the observation group had a significantly shorter operation time, lower visual analogue scale score, less intraoperative bleeding, and shorter fracture healing time. There were no significant differences in the angulation, reduction, neck-shaft angle, and limb length discrepancy between the two groups. Conclusion: The minimally invasive wire guide achieved a similar effect to that of open reduction in the treatment of intertrochanteric fractures with difficult reduction. Moreover, the minimally invasive wire introducer is a good technology that accurately guides the wire during reduction. Indeed, it is an effective technique and achieves good clinical outcomes in restoration of irreducible femoral intertrochanteric fractures.
|