Removal of lead from crude antimony by using NaPo3 as lead elimination reagent

In order to solve the shortcomings when removing lead from crude antimony in the traditional antimony smelting, a new process was provided using NaPO3 as lead elimination reagent to yield phosphate slag, and it was removed by floating on the surface of the liquid antimony. Reaction mechanis...

Full description

Bibliographic Details
Main Authors: Ye L.G., Tang C.B., Yang S.H., Chen Y.M., Zhang W.H.
Format: Article
Language:English
Published: Technical Faculty, Bor 2015-01-01
Series:Journal of Mining and Metallurgy. Section B: Metallurgy
Subjects:
XRD
Online Access:http://www.doiserbia.nb.rs/img/doi/1450-5339/2015/1450-53391500011Y.pdf
id doaj-268424e9aef54c0184621839564acbe1
record_format Article
spelling doaj-268424e9aef54c0184621839564acbe12020-11-24T22:02:29ZengTechnical Faculty, BorJournal of Mining and Metallurgy. Section B: Metallurgy1450-53392217-71752015-01-015119710310.2298/JMMB130904011Y1450-53391500011YRemoval of lead from crude antimony by using NaPo3 as lead elimination reagentYe L.G.0Tang C.B.1Yang S.H.2Chen Y.M.3Zhang W.H.4Central South University, School of Metallurgy and Environment, Hunan, ChinaCentral South University, School of Metallurgy and Environment, Hunan, ChinaCentral South University, School of Metallurgy and Environment, Hunan, ChinaCentral South University, School of Metallurgy and Environment, Hunan, ChinaCentral South University, School of Metallurgy and Environment, Hunan, ChinaIn order to solve the shortcomings when removing lead from crude antimony in the traditional antimony smelting, a new process was provided using NaPO3 as lead elimination reagent to yield phosphate slag, and it was removed by floating on the surface of the liquid antimony. Reaction mechanism was clarified by using the TG-DTA and XRD techniques and single factor experiments of removal lead from crude antimony were engaged. The results show that PbO and NaPO3 begin endothermic reaction at 863K (590°C), and the reaction mainly form NaPb4(PO4)3 and NaPbPO4 below 1123K (850°C) and above 1123K (850°C), respectively. Sb2O3 and NaPO3 start the reaction at 773K (500°C) and generate an antimonic salt compound. The reaction product of the mixture of PbO, Sb2O3 and NaPO3 show that NaPO3 reacted with PbO prior when NaPO3 was insufficient, amorphous antimony glass will be generated only when NaPO3 was adequate. Single factor experiments were taken with NaNO3 as oxidizing agent under argon, effect of reaction time, reaction temperature and dosage of NaPO3 and NaNO3 on smelting results. The average content of lead in refined antimony was 0.05340% and 98.85% of lead were removed under optimal conditions; the content of lead in antimony have meet the requirements of commercial antimony.http://www.doiserbia.nb.rs/img/doi/1450-5339/2015/1450-53391500011Y.pdfantimonysodium metaphosphateXRDlead elimination reagentpyro-refining
collection DOAJ
language English
format Article
sources DOAJ
author Ye L.G.
Tang C.B.
Yang S.H.
Chen Y.M.
Zhang W.H.
spellingShingle Ye L.G.
Tang C.B.
Yang S.H.
Chen Y.M.
Zhang W.H.
Removal of lead from crude antimony by using NaPo3 as lead elimination reagent
Journal of Mining and Metallurgy. Section B: Metallurgy
antimony
sodium metaphosphate
XRD
lead elimination reagent
pyro-refining
author_facet Ye L.G.
Tang C.B.
Yang S.H.
Chen Y.M.
Zhang W.H.
author_sort Ye L.G.
title Removal of lead from crude antimony by using NaPo3 as lead elimination reagent
title_short Removal of lead from crude antimony by using NaPo3 as lead elimination reagent
title_full Removal of lead from crude antimony by using NaPo3 as lead elimination reagent
title_fullStr Removal of lead from crude antimony by using NaPo3 as lead elimination reagent
title_full_unstemmed Removal of lead from crude antimony by using NaPo3 as lead elimination reagent
title_sort removal of lead from crude antimony by using napo3 as lead elimination reagent
publisher Technical Faculty, Bor
series Journal of Mining and Metallurgy. Section B: Metallurgy
issn 1450-5339
2217-7175
publishDate 2015-01-01
description In order to solve the shortcomings when removing lead from crude antimony in the traditional antimony smelting, a new process was provided using NaPO3 as lead elimination reagent to yield phosphate slag, and it was removed by floating on the surface of the liquid antimony. Reaction mechanism was clarified by using the TG-DTA and XRD techniques and single factor experiments of removal lead from crude antimony were engaged. The results show that PbO and NaPO3 begin endothermic reaction at 863K (590°C), and the reaction mainly form NaPb4(PO4)3 and NaPbPO4 below 1123K (850°C) and above 1123K (850°C), respectively. Sb2O3 and NaPO3 start the reaction at 773K (500°C) and generate an antimonic salt compound. The reaction product of the mixture of PbO, Sb2O3 and NaPO3 show that NaPO3 reacted with PbO prior when NaPO3 was insufficient, amorphous antimony glass will be generated only when NaPO3 was adequate. Single factor experiments were taken with NaNO3 as oxidizing agent under argon, effect of reaction time, reaction temperature and dosage of NaPO3 and NaNO3 on smelting results. The average content of lead in refined antimony was 0.05340% and 98.85% of lead were removed under optimal conditions; the content of lead in antimony have meet the requirements of commercial antimony.
topic antimony
sodium metaphosphate
XRD
lead elimination reagent
pyro-refining
url http://www.doiserbia.nb.rs/img/doi/1450-5339/2015/1450-53391500011Y.pdf
work_keys_str_mv AT yelg removalofleadfromcrudeantimonybyusingnapo3asleadeliminationreagent
AT tangcb removalofleadfromcrudeantimonybyusingnapo3asleadeliminationreagent
AT yangsh removalofleadfromcrudeantimonybyusingnapo3asleadeliminationreagent
AT chenym removalofleadfromcrudeantimonybyusingnapo3asleadeliminationreagent
AT zhangwh removalofleadfromcrudeantimonybyusingnapo3asleadeliminationreagent
_version_ 1725835563374739456