spelling doaj-268dd47737b8416bbd2534eaae796bc22021-07-02T04:18:27ZengElsevierHeartRhythm Case Reports2214-02712018-01-0141293010.1016/j.hrcr.2017.10.017Subcutaneous ICD lead position affects defibrillation thresholdHariharan Sugumar, MBBS, BMedSci0Matthew K. Tung, MBBS1Arthur J. Lee, MD2Jamil Bashir, MD3Christopher Lane, MD4Royal Jubilee Hospital, Victoria, CanadaRoyal Jubilee Hospital, Victoria, CanadaUniversity of British Columbia Division of Cardiovascular Surgery, St. Paul’s Hospital, Providence Health, Vancouver, CanadaUniversity of British Columbia Division of Cardiovascular Surgery, St. Paul’s Hospital, Providence Health, Vancouver, CanadaRoyal Jubilee Hospital, Victoria, Canadahttp://www.sciencedirect.com/science/article/pii/S2214027117301896Failure to defibrillateHigh thresholdReposition leadSubcutaneous ICDShock vectorScreening at implant
collection DOAJ
language English
format Article
sources DOAJ
author Hariharan Sugumar, MBBS, BMedSci
Matthew K. Tung, MBBS
Arthur J. Lee, MD
Jamil Bashir, MD
Christopher Lane, MD
spellingShingle Hariharan Sugumar, MBBS, BMedSci
Matthew K. Tung, MBBS
Arthur J. Lee, MD
Jamil Bashir, MD
Christopher Lane, MD
Subcutaneous ICD lead position affects defibrillation threshold
HeartRhythm Case Reports
Failure to defibrillate
High threshold
Reposition lead
Subcutaneous ICD
Shock vector
Screening at implant
author_facet Hariharan Sugumar, MBBS, BMedSci
Matthew K. Tung, MBBS
Arthur J. Lee, MD
Jamil Bashir, MD
Christopher Lane, MD
author_sort Hariharan Sugumar, MBBS, BMedSci
title Subcutaneous ICD lead position affects defibrillation threshold
title_short Subcutaneous ICD lead position affects defibrillation threshold
title_full Subcutaneous ICD lead position affects defibrillation threshold
title_fullStr Subcutaneous ICD lead position affects defibrillation threshold
title_full_unstemmed Subcutaneous ICD lead position affects defibrillation threshold
title_sort subcutaneous icd lead position affects defibrillation threshold
publisher Elsevier
series HeartRhythm Case Reports
issn 2214-0271
publishDate 2018-01-01
topic Failure to defibrillate
High threshold
Reposition lead
Subcutaneous ICD
Shock vector
Screening at implant
url http://www.sciencedirect.com/science/article/pii/S2214027117301896
work_keys_str_mv AT hariharansugumarmbbsbmedsci subcutaneousicdleadpositionaffectsdefibrillationthreshold
AT matthewktungmbbs subcutaneousicdleadpositionaffectsdefibrillationthreshold
AT arthurjleemd subcutaneousicdleadpositionaffectsdefibrillationthreshold
AT jamilbashirmd subcutaneousicdleadpositionaffectsdefibrillationthreshold
AT christopherlanemd subcutaneousicdleadpositionaffectsdefibrillationthreshold
_version_ 1721340330117169152