Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms

A reliable method using LC-UV to assay mometasone furoate (MF) in creams or nasal sprays using the same chromatographic conditions was set up. Methanol:water 80:20 (v/v) (1.0 mL min-1) was used as mobile phase. MF was detected at 248 nm and analyzed in a concentration range from 1.0 to 20.0 µg mL-1....

Full description

Bibliographic Details
Main Authors: Aline Ferreira Ourique, Renata Vidor Contri, Silvia Stanisçuaski Guterres, Ruy Carlos Ruver Beck, Adriana Raffin Pohlmann, Ana Melero, Ulrich F. Schaefer
Format: Article
Language:English
Published: Sociedade Brasileira de Química 2012-01-01
Series:Química Nova
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000400030&lng=en&tlng=en
id doaj-26c36bd6dab84da1b7bae7339abbc489
record_format Article
spelling doaj-26c36bd6dab84da1b7bae7339abbc4892020-11-24T23:31:23ZengSociedade Brasileira de QuímicaQuímica Nova1678-70642012-01-0135481882110.1590/S0100-40422012000400030S0100-40422012000400030Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage formsAline Ferreira Ourique0Renata Vidor Contri1Silvia Stanisçuaski Guterres2Ruy Carlos Ruver Beck3Adriana Raffin Pohlmann4Ana Melero5Ulrich F. Schaefer6Universidade Federal do Rio Grande do SulUniversidade Federal do Rio Grande do SulUniversidade Federal do Rio Grande do SulUniversidade Federal do Rio Grande do SulUniversidade Federal do Rio Grande do SulUniversität des SaarlandesUniversität des SaarlandesA reliable method using LC-UV to assay mometasone furoate (MF) in creams or nasal sprays using the same chromatographic conditions was set up. Methanol:water 80:20 (v/v) (1.0 mL min-1) was used as mobile phase. MF was detected at 248 nm and analyzed in a concentration range from 1.0 to 20.0 µg mL-1. The method provided acceptable theoretical plates, peak simmetry, peak tailing factor and peak resolution a short run (5 min). The method showed specificity, good linearity (r = 0.9999) and the quantification limit was 0.379 µg mL-1. Furthermore, the method was precise (RSD < 2.0%), accurate (recovery > 97%) and robust.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000400030&lng=en&tlng=enpharmaceuticalsliquid chromatographymometasone
collection DOAJ
language English
format Article
sources DOAJ
author Aline Ferreira Ourique
Renata Vidor Contri
Silvia Stanisçuaski Guterres
Ruy Carlos Ruver Beck
Adriana Raffin Pohlmann
Ana Melero
Ulrich F. Schaefer
spellingShingle Aline Ferreira Ourique
Renata Vidor Contri
Silvia Stanisçuaski Guterres
Ruy Carlos Ruver Beck
Adriana Raffin Pohlmann
Ana Melero
Ulrich F. Schaefer
Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms
Química Nova
pharmaceuticals
liquid chromatography
mometasone
author_facet Aline Ferreira Ourique
Renata Vidor Contri
Silvia Stanisçuaski Guterres
Ruy Carlos Ruver Beck
Adriana Raffin Pohlmann
Ana Melero
Ulrich F. Schaefer
author_sort Aline Ferreira Ourique
title Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms
title_short Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms
title_full Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms
title_fullStr Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms
title_full_unstemmed Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms
title_sort set-up of a method using lc-uv to assay mometasone furoate in pharmaceutical dosage forms
publisher Sociedade Brasileira de Química
series Química Nova
issn 1678-7064
publishDate 2012-01-01
description A reliable method using LC-UV to assay mometasone furoate (MF) in creams or nasal sprays using the same chromatographic conditions was set up. Methanol:water 80:20 (v/v) (1.0 mL min-1) was used as mobile phase. MF was detected at 248 nm and analyzed in a concentration range from 1.0 to 20.0 µg mL-1. The method provided acceptable theoretical plates, peak simmetry, peak tailing factor and peak resolution a short run (5 min). The method showed specificity, good linearity (r = 0.9999) and the quantification limit was 0.379 µg mL-1. Furthermore, the method was precise (RSD < 2.0%), accurate (recovery > 97%) and robust.
topic pharmaceuticals
liquid chromatography
mometasone
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000400030&lng=en&tlng=en
work_keys_str_mv AT alineferreiraourique setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms
AT renatavidorcontri setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms
AT silviastaniscuaskiguterres setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms
AT ruycarlosruverbeck setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms
AT adrianaraffinpohlmann setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms
AT anamelero setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms
AT ulrichfschaefer setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms
_version_ 1725538194556977152