Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms
A reliable method using LC-UV to assay mometasone furoate (MF) in creams or nasal sprays using the same chromatographic conditions was set up. Methanol:water 80:20 (v/v) (1.0 mL min-1) was used as mobile phase. MF was detected at 248 nm and analyzed in a concentration range from 1.0 to 20.0 µg mL-1....
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sociedade Brasileira de Química
2012-01-01
|
Series: | Química Nova |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000400030&lng=en&tlng=en |
id |
doaj-26c36bd6dab84da1b7bae7339abbc489 |
---|---|
record_format |
Article |
spelling |
doaj-26c36bd6dab84da1b7bae7339abbc4892020-11-24T23:31:23ZengSociedade Brasileira de QuímicaQuímica Nova1678-70642012-01-0135481882110.1590/S0100-40422012000400030S0100-40422012000400030Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage formsAline Ferreira Ourique0Renata Vidor Contri1Silvia Stanisçuaski Guterres2Ruy Carlos Ruver Beck3Adriana Raffin Pohlmann4Ana Melero5Ulrich F. Schaefer6Universidade Federal do Rio Grande do SulUniversidade Federal do Rio Grande do SulUniversidade Federal do Rio Grande do SulUniversidade Federal do Rio Grande do SulUniversidade Federal do Rio Grande do SulUniversität des SaarlandesUniversität des SaarlandesA reliable method using LC-UV to assay mometasone furoate (MF) in creams or nasal sprays using the same chromatographic conditions was set up. Methanol:water 80:20 (v/v) (1.0 mL min-1) was used as mobile phase. MF was detected at 248 nm and analyzed in a concentration range from 1.0 to 20.0 µg mL-1. The method provided acceptable theoretical plates, peak simmetry, peak tailing factor and peak resolution a short run (5 min). The method showed specificity, good linearity (r = 0.9999) and the quantification limit was 0.379 µg mL-1. Furthermore, the method was precise (RSD < 2.0%), accurate (recovery > 97%) and robust.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000400030&lng=en&tlng=enpharmaceuticalsliquid chromatographymometasone |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Aline Ferreira Ourique Renata Vidor Contri Silvia Stanisçuaski Guterres Ruy Carlos Ruver Beck Adriana Raffin Pohlmann Ana Melero Ulrich F. Schaefer |
spellingShingle |
Aline Ferreira Ourique Renata Vidor Contri Silvia Stanisçuaski Guterres Ruy Carlos Ruver Beck Adriana Raffin Pohlmann Ana Melero Ulrich F. Schaefer Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms Química Nova pharmaceuticals liquid chromatography mometasone |
author_facet |
Aline Ferreira Ourique Renata Vidor Contri Silvia Stanisçuaski Guterres Ruy Carlos Ruver Beck Adriana Raffin Pohlmann Ana Melero Ulrich F. Schaefer |
author_sort |
Aline Ferreira Ourique |
title |
Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms |
title_short |
Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms |
title_full |
Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms |
title_fullStr |
Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms |
title_full_unstemmed |
Set-up of a method using LC-UV to assay mometasone furoate in pharmaceutical dosage forms |
title_sort |
set-up of a method using lc-uv to assay mometasone furoate in pharmaceutical dosage forms |
publisher |
Sociedade Brasileira de Química |
series |
Química Nova |
issn |
1678-7064 |
publishDate |
2012-01-01 |
description |
A reliable method using LC-UV to assay mometasone furoate (MF) in creams or nasal sprays using the same chromatographic conditions was set up. Methanol:water 80:20 (v/v) (1.0 mL min-1) was used as mobile phase. MF was detected at 248 nm and analyzed in a concentration range from 1.0 to 20.0 µg mL-1. The method provided acceptable theoretical plates, peak simmetry, peak tailing factor and peak resolution a short run (5 min). The method showed specificity, good linearity (r = 0.9999) and the quantification limit was 0.379 µg mL-1. Furthermore, the method was precise (RSD < 2.0%), accurate (recovery > 97%) and robust. |
topic |
pharmaceuticals liquid chromatography mometasone |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000400030&lng=en&tlng=en |
work_keys_str_mv |
AT alineferreiraourique setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms AT renatavidorcontri setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms AT silviastaniscuaskiguterres setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms AT ruycarlosruverbeck setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms AT adrianaraffinpohlmann setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms AT anamelero setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms AT ulrichfschaefer setupofamethodusinglcuvtoassaymometasonefuroateinpharmaceuticaldosageforms |
_version_ |
1725538194556977152 |