Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP
An experimental study has been made of the hydrodynamics of a stage mixer-settler to obtain appropriate design information. In this paper several tests were done according to full factorial design of experiments with high reliability, since each test recurs seven times and the results of them are v...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR
2009-03-01
|
Series: | Iranian Journal of Chemistry & Chemical Engineering |
Subjects: | |
Online Access: | http://www.ijcce.ac.ir/article_6919_6ec2908984de5279ffea6a35fa3def84.pdf |
id |
doaj-298b5237fda0434dbf4a6014cb8d8f29 |
---|---|
record_format |
Article |
spelling |
doaj-298b5237fda0434dbf4a6014cb8d8f292020-11-25T03:46:43ZengIranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECRIranian Journal of Chemistry & Chemical Engineering 1021-99861021-99862009-03-0128185936919Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBPFatemeh Gharehbagh0Sayed Mohammad Ali Mousavian1Kamal Saberyan2Department of Chemical Engineering, Faculty of Engineering, University of Tehran, Tehran, I.R. IRANDepartment of Chemical Engineering, Faculty of Engineering, University of Tehran, Tehran, I.R. IRANChemistry Research Department, Nuclear Science Research School, Tehran, I.R. IRANAn experimental study has been made of the hydrodynamics of a stage mixer-settler to obtain appropriate design information. In this paper several tests were done according to full factorial design of experiments with high reliability, since each test recurs seven times and the results of them are very close to each other(P=1bar and T=25 °C). Sauter diameter in each test is determined with photographing of both mixer and settler and holdup quantity is measured by vacuum pump at the end of each test. In each test, dispersion height and dispersion length are determined by photographing of settler. Sauter diameter has been compared with Calderbank model and finally, a model has been suggested.http://www.ijcce.ac.ir/article_6919_6ec2908984de5279ffea6a35fa3def84.pdfmixer-settlerdispersion heightdispersion lengthdrop sizedispersed phase hold uptri-butyle phosphate |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Fatemeh Gharehbagh Sayed Mohammad Ali Mousavian Kamal Saberyan |
spellingShingle |
Fatemeh Gharehbagh Sayed Mohammad Ali Mousavian Kamal Saberyan Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP Iranian Journal of Chemistry & Chemical Engineering mixer-settler dispersion height dispersion length drop size dispersed phase hold up tri-butyle phosphate |
author_facet |
Fatemeh Gharehbagh Sayed Mohammad Ali Mousavian Kamal Saberyan |
author_sort |
Fatemeh Gharehbagh |
title |
Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP |
title_short |
Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP |
title_full |
Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP |
title_fullStr |
Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP |
title_full_unstemmed |
Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP |
title_sort |
hydrodynamic characterization of mixer-settlers in extraction of zirconium with tbp |
publisher |
Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR |
series |
Iranian Journal of Chemistry & Chemical Engineering |
issn |
1021-9986 1021-9986 |
publishDate |
2009-03-01 |
description |
An experimental study has been made of the hydrodynamics of a stage mixer-settler to obtain appropriate design information. In this paper several tests were done according to full factorial design of experiments with high reliability, since each test recurs seven times and the results of them are very close to each other(P=1bar and T=25 °C). Sauter diameter in each test is determined with photographing of both mixer and settler and holdup quantity is measured by vacuum pump at the end of each test. In each test, dispersion height and dispersion length are determined by photographing of settler. Sauter diameter has been compared with Calderbank model and finally, a model has been suggested. |
topic |
mixer-settler dispersion height dispersion length drop size dispersed phase hold up tri-butyle phosphate |
url |
http://www.ijcce.ac.ir/article_6919_6ec2908984de5279ffea6a35fa3def84.pdf |
work_keys_str_mv |
AT fatemehgharehbagh hydrodynamiccharacterizationofmixersettlersinextractionofzirconiumwithtbp AT sayedmohammadalimousavian hydrodynamiccharacterizationofmixersettlersinextractionofzirconiumwithtbp AT kamalsaberyan hydrodynamiccharacterizationofmixersettlersinextractionofzirconiumwithtbp |
_version_ |
1724504712184594432 |