Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP

An experimental study has been made of the hydrodynamics of a stage mixer-settler to obtain appropriate design information. In this paper several tests were done according to full factorial design of experiments with high reliability, since each test recurs seven times and the results of  them are v...

Full description

Bibliographic Details
Main Authors: Fatemeh Gharehbagh, Sayed Mohammad Ali Mousavian, Kamal Saberyan
Format: Article
Language:English
Published: Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR 2009-03-01
Series:Iranian Journal of Chemistry & Chemical Engineering
Subjects:
Online Access:http://www.ijcce.ac.ir/article_6919_6ec2908984de5279ffea6a35fa3def84.pdf
id doaj-298b5237fda0434dbf4a6014cb8d8f29
record_format Article
spelling doaj-298b5237fda0434dbf4a6014cb8d8f292020-11-25T03:46:43ZengIranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECRIranian Journal of Chemistry & Chemical Engineering 1021-99861021-99862009-03-0128185936919Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBPFatemeh Gharehbagh0Sayed Mohammad Ali Mousavian1Kamal Saberyan2Department of Chemical Engineering, Faculty of Engineering, University of Tehran, Tehran, I.R. IRANDepartment of Chemical Engineering, Faculty of Engineering, University of Tehran, Tehran, I.R. IRANChemistry Research Department, Nuclear Science Research School, Tehran, I.R. IRANAn experimental study has been made of the hydrodynamics of a stage mixer-settler to obtain appropriate design information. In this paper several tests were done according to full factorial design of experiments with high reliability, since each test recurs seven times and the results of  them are very close to each other(P=1bar and T=25 °C). Sauter diameter in each test is determined with photographing of both mixer and settler and holdup quantity is measured by vacuum pump at the end of each test. In each test, dispersion height and dispersion length are determined by photographing of settler. Sauter diameter has been compared with Calderbank model and finally, a model has been suggested.http://www.ijcce.ac.ir/article_6919_6ec2908984de5279ffea6a35fa3def84.pdfmixer-settlerdispersion heightdispersion lengthdrop sizedispersed phase hold uptri-butyle phosphate
collection DOAJ
language English
format Article
sources DOAJ
author Fatemeh Gharehbagh
Sayed Mohammad Ali Mousavian
Kamal Saberyan
spellingShingle Fatemeh Gharehbagh
Sayed Mohammad Ali Mousavian
Kamal Saberyan
Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP
Iranian Journal of Chemistry & Chemical Engineering
mixer-settler
dispersion height
dispersion length
drop size
dispersed phase hold up
tri-butyle phosphate
author_facet Fatemeh Gharehbagh
Sayed Mohammad Ali Mousavian
Kamal Saberyan
author_sort Fatemeh Gharehbagh
title Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP
title_short Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP
title_full Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP
title_fullStr Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP
title_full_unstemmed Hydrodynamic Characterization of Mixer-Settlers in Extraction of Zirconium with TBP
title_sort hydrodynamic characterization of mixer-settlers in extraction of zirconium with tbp
publisher Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR
series Iranian Journal of Chemistry & Chemical Engineering
issn 1021-9986
1021-9986
publishDate 2009-03-01
description An experimental study has been made of the hydrodynamics of a stage mixer-settler to obtain appropriate design information. In this paper several tests were done according to full factorial design of experiments with high reliability, since each test recurs seven times and the results of  them are very close to each other(P=1bar and T=25 °C). Sauter diameter in each test is determined with photographing of both mixer and settler and holdup quantity is measured by vacuum pump at the end of each test. In each test, dispersion height and dispersion length are determined by photographing of settler. Sauter diameter has been compared with Calderbank model and finally, a model has been suggested.
topic mixer-settler
dispersion height
dispersion length
drop size
dispersed phase hold up
tri-butyle phosphate
url http://www.ijcce.ac.ir/article_6919_6ec2908984de5279ffea6a35fa3def84.pdf
work_keys_str_mv AT fatemehgharehbagh hydrodynamiccharacterizationofmixersettlersinextractionofzirconiumwithtbp
AT sayedmohammadalimousavian hydrodynamiccharacterizationofmixersettlersinextractionofzirconiumwithtbp
AT kamalsaberyan hydrodynamiccharacterizationofmixersettlersinextractionofzirconiumwithtbp
_version_ 1724504712184594432