Análise do comportamento hemodinâmico de conduto valvado de pericárdio bovino, implantado em posição aórtica de ovinos Analysis of hemodynamic performance of the bovine pericardium valved conduit, implanted in the aortic position in ovines
OBJETIVOS: A necessidade de substituição da valva, aorta ascendente e reimplante coronariano em pacientes onde a anticoagulação é indesejável, é crescente. Avaliamos em animais o comportamento hemodinâmico de um conduto valvado aórtico feito com pericárdio bovino tratado pelo glutaraldeído (CVAP). M...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sociedade Brasileira de Cirurgia Cardiovascular
2010-12-01
|
Series: | Brazilian Journal of Cardiovascular Surgery |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382010000400019 |
id |
doaj-2a176b315b504067a550e34d3ffb61cf |
---|---|
record_format |
Article |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Josalmir José Melo do Amaral Pablo Maria Alberto Pomerantzeff Ivan Sergio Joviano Casagrande Idágene Aparecida Cestari Paulo Sampaio Gutierrez Noedir Groppo Stolf |
spellingShingle |
Josalmir José Melo do Amaral Pablo Maria Alberto Pomerantzeff Ivan Sergio Joviano Casagrande Idágene Aparecida Cestari Paulo Sampaio Gutierrez Noedir Groppo Stolf Análise do comportamento hemodinâmico de conduto valvado de pericárdio bovino, implantado em posição aórtica de ovinos Analysis of hemodynamic performance of the bovine pericardium valved conduit, implanted in the aortic position in ovines Brazilian Journal of Cardiovascular Surgery Valva aórtica Próteses valvulares cardíacas Modelos animais Ovinos Aortic valve Heart valve prosthesis Models, animal Sheep |
author_facet |
Josalmir José Melo do Amaral Pablo Maria Alberto Pomerantzeff Ivan Sergio Joviano Casagrande Idágene Aparecida Cestari Paulo Sampaio Gutierrez Noedir Groppo Stolf |
author_sort |
Josalmir José Melo do Amaral |
title |
Análise do comportamento hemodinâmico de conduto valvado de pericárdio bovino, implantado em posição aórtica de ovinos Analysis of hemodynamic performance of the bovine pericardium valved conduit, implanted in the aortic position in ovines |
title_short |
Análise do comportamento hemodinâmico de conduto valvado de pericárdio bovino, implantado em posição aórtica de ovinos Analysis of hemodynamic performance of the bovine pericardium valved conduit, implanted in the aortic position in ovines |
title_full |
Análise do comportamento hemodinâmico de conduto valvado de pericárdio bovino, implantado em posição aórtica de ovinos Analysis of hemodynamic performance of the bovine pericardium valved conduit, implanted in the aortic position in ovines |
title_fullStr |
Análise do comportamento hemodinâmico de conduto valvado de pericárdio bovino, implantado em posição aórtica de ovinos Analysis of hemodynamic performance of the bovine pericardium valved conduit, implanted in the aortic position in ovines |
title_full_unstemmed |
Análise do comportamento hemodinâmico de conduto valvado de pericárdio bovino, implantado em posição aórtica de ovinos Analysis of hemodynamic performance of the bovine pericardium valved conduit, implanted in the aortic position in ovines |
title_sort |
análise do comportamento hemodinâmico de conduto valvado de pericárdio bovino, implantado em posição aórtica de ovinos analysis of hemodynamic performance of the bovine pericardium valved conduit, implanted in the aortic position in ovines |
publisher |
Sociedade Brasileira de Cirurgia Cardiovascular |
series |
Brazilian Journal of Cardiovascular Surgery |
issn |
0102-7638 1678-9741 |
publishDate |
2010-12-01 |
description |
OBJETIVOS: A necessidade de substituição da valva, aorta ascendente e reimplante coronariano em pacientes onde a anticoagulação é indesejável, é crescente. Avaliamos em animais o comportamento hemodinâmico de um conduto valvado aórtico feito com pericárdio bovino tratado pelo glutaraldeído (CVAP). MÉTODOS: Para isto, implantamos CVAPs em oito ovinos e os explantamos após 150 dias de pós-operatório. Realizouse estudo angiográfico e hemodinâmico no pré-operatório e antes do explante. EcoDopplercardiogramas foram realizados nos dias 30 e 150 de pós-operatório (teste) e também em cinco ovinos não operados. Após explantados, submetemos os CVAPs à avaliação macroscópica, radiológica e histológica por microscopia óptica. RESULTADOS: Na análise hemodinâmica, as pressões arterial e capilar pulmonar aumentaram (P<0,05) entre os dias 0 e 150. Na análise ecoDopplercardiográfica, o grupo teste apresentou incremento dos diâmetros diastólicos e sistólicos do ventrículo esquerdo (P<0,05). O grupo teste entre os dias 30 e 150 aumentou: peso, espessura das paredes do ventrículo esquerdo, gradiente transvalvar máximo, gradiente transvalvar médio, diâmetro diastólico do ventrículo esquerdo e decréscimo da fração de ejeção (P<0,05). Dois animais com endocardite explicam essas diferenças, tal como demonstrado na análise estatística realizada sem a presença desses animais. A macroscopia demonstrou calcificação de grau variável. A microscopia óptica demonstrou similaridade com a literatura quanto ao uso do pericárdio bovino tratado pelo glutaraldeído. CONCLUSÕES: Estes dados indicam que o CVAP permite a realização desse tipo de experimento no modelo proposto e que os resultados hemodinâmicos encontrados se assemelham aos parâmetros fisiológicos.<br>OBJECTIVE: The necessity for replacement of the valve, ascending aorta and aortic with coronary reimplantation in patients where anti-coagulation is undesirable, is increasing. We evaluated the hemodynamic performance of an aortic valved conduit made with glutaraldehyde treated bovine pericardium (AVCP) in animals. METHODS: Therefore, AVCPs were implanted in eight young ovine and explanted after 150 days. Angiographic and hemodynamic study was performed at pre-operative and prior the explant. EchoDopplercardiograms were performed at day 30 and 150 of post-operative (test) and also in five nonoperated ovines. After explanted, AVCPs were submitted to a macroscopical, radiological and histological evaluation by optic microscopy. RESULTS: In the hemodynamic analysis the arterial and pulmonary capillary pressure increased (P<0.05) between day 0 and 150. In the echoDoppercardiographic analysis, the test group presented higher values in the diastolic and systolic diameters of the left ventricle (P<0.05). In the test group, between day 30 and 150, occurred an increase of weight, thickness of the left ventricle walls, maximum transvalvar gradient, medium transvalvar gradient, left ventricle diastolic diameter and a decrease in the ejection function (P<0.05). Two animals with endocarditis explain those differences, how we can see with the statistycal analysis without this sample. Macroscopy showed calcification in variable degrees. Optic microscopy revealed data similar to literature with the use of glutaraldehyde treated bovine pericadium. CONCLUSIONS: These data indicate that the AVCPs allows the performance of this kind of experiment in the proposed model and that the hemodynamic outcomes found are similar to physiological parameters. |
topic |
Valva aórtica Próteses valvulares cardíacas Modelos animais Ovinos Aortic valve Heart valve prosthesis Models, animal Sheep |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382010000400019 |
work_keys_str_mv |
AT josalmirjosemelodoamaral analisedocomportamentohemodinamicodecondutovalvadodepericardiobovinoimplantadoemposicaoaorticadeovinosanalysisofhemodynamicperformanceofthebovinepericardiumvalvedconduitimplantedintheaorticpositioninovines AT pablomariaalbertopomerantzeff analisedocomportamentohemodinamicodecondutovalvadodepericardiobovinoimplantadoemposicaoaorticadeovinosanalysisofhemodynamicperformanceofthebovinepericardiumvalvedconduitimplantedintheaorticpositioninovines AT ivansergiojovianocasagrande analisedocomportamentohemodinamicodecondutovalvadodepericardiobovinoimplantadoemposicaoaorticadeovinosanalysisofhemodynamicperformanceofthebovinepericardiumvalvedconduitimplantedintheaorticpositioninovines AT idageneaparecidacestari analisedocomportamentohemodinamicodecondutovalvadodepericardiobovinoimplantadoemposicaoaorticadeovinosanalysisofhemodynamicperformanceofthebovinepericardiumvalvedconduitimplantedintheaorticpositioninovines AT paulosampaiogutierrez analisedocomportamentohemodinamicodecondutovalvadodepericardiobovinoimplantadoemposicaoaorticadeovinosanalysisofhemodynamicperformanceofthebovinepericardiumvalvedconduitimplantedintheaorticpositioninovines AT noedirgroppostolf analisedocomportamentohemodinamicodecondutovalvadodepericardiobovinoimplantadoemposicaoaorticadeovinosanalysisofhemodynamicperformanceofthebovinepericardiumvalvedconduitimplantedintheaorticpositioninovines |
_version_ |
1725518752896778240 |
spelling |
doaj-2a176b315b504067a550e34d3ffb61cf2020-11-24T23:37:50ZengSociedade Brasileira de Cirurgia CardiovascularBrazilian Journal of Cardiovascular Surgery0102-76381678-97412010-12-0125454355110.1590/S0102-76382010000400019Análise do comportamento hemodinâmico de conduto valvado de pericárdio bovino, implantado em posição aórtica de ovinos Analysis of hemodynamic performance of the bovine pericardium valved conduit, implanted in the aortic position in ovinesJosalmir José Melo do AmaralPablo Maria Alberto PomerantzeffIvan Sergio Joviano CasagrandeIdágene Aparecida CestariPaulo Sampaio GutierrezNoedir Groppo StolfOBJETIVOS: A necessidade de substituição da valva, aorta ascendente e reimplante coronariano em pacientes onde a anticoagulação é indesejável, é crescente. Avaliamos em animais o comportamento hemodinâmico de um conduto valvado aórtico feito com pericárdio bovino tratado pelo glutaraldeído (CVAP). MÉTODOS: Para isto, implantamos CVAPs em oito ovinos e os explantamos após 150 dias de pós-operatório. Realizouse estudo angiográfico e hemodinâmico no pré-operatório e antes do explante. EcoDopplercardiogramas foram realizados nos dias 30 e 150 de pós-operatório (teste) e também em cinco ovinos não operados. Após explantados, submetemos os CVAPs à avaliação macroscópica, radiológica e histológica por microscopia óptica. RESULTADOS: Na análise hemodinâmica, as pressões arterial e capilar pulmonar aumentaram (P<0,05) entre os dias 0 e 150. Na análise ecoDopplercardiográfica, o grupo teste apresentou incremento dos diâmetros diastólicos e sistólicos do ventrículo esquerdo (P<0,05). O grupo teste entre os dias 30 e 150 aumentou: peso, espessura das paredes do ventrículo esquerdo, gradiente transvalvar máximo, gradiente transvalvar médio, diâmetro diastólico do ventrículo esquerdo e decréscimo da fração de ejeção (P<0,05). Dois animais com endocardite explicam essas diferenças, tal como demonstrado na análise estatística realizada sem a presença desses animais. A macroscopia demonstrou calcificação de grau variável. A microscopia óptica demonstrou similaridade com a literatura quanto ao uso do pericárdio bovino tratado pelo glutaraldeído. CONCLUSÕES: Estes dados indicam que o CVAP permite a realização desse tipo de experimento no modelo proposto e que os resultados hemodinâmicos encontrados se assemelham aos parâmetros fisiológicos.<br>OBJECTIVE: The necessity for replacement of the valve, ascending aorta and aortic with coronary reimplantation in patients where anti-coagulation is undesirable, is increasing. We evaluated the hemodynamic performance of an aortic valved conduit made with glutaraldehyde treated bovine pericardium (AVCP) in animals. METHODS: Therefore, AVCPs were implanted in eight young ovine and explanted after 150 days. Angiographic and hemodynamic study was performed at pre-operative and prior the explant. EchoDopplercardiograms were performed at day 30 and 150 of post-operative (test) and also in five nonoperated ovines. After explanted, AVCPs were submitted to a macroscopical, radiological and histological evaluation by optic microscopy. RESULTS: In the hemodynamic analysis the arterial and pulmonary capillary pressure increased (P<0.05) between day 0 and 150. In the echoDoppercardiographic analysis, the test group presented higher values in the diastolic and systolic diameters of the left ventricle (P<0.05). In the test group, between day 30 and 150, occurred an increase of weight, thickness of the left ventricle walls, maximum transvalvar gradient, medium transvalvar gradient, left ventricle diastolic diameter and a decrease in the ejection function (P<0.05). Two animals with endocarditis explain those differences, how we can see with the statistycal analysis without this sample. Macroscopy showed calcification in variable degrees. Optic microscopy revealed data similar to literature with the use of glutaraldehyde treated bovine pericadium. CONCLUSIONS: These data indicate that the AVCPs allows the performance of this kind of experiment in the proposed model and that the hemodynamic outcomes found are similar to physiological parameters.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382010000400019Valva aórticaPróteses valvulares cardíacasModelos animaisOvinosAortic valveHeart valve prosthesisModels, animalSheep |