A Preliminary Study on the Diagnostic Efficacy of Proton Magnetic Resonance Spectroscopy at 3.0T in Rabbit With VX2 Liver Tumor

Background: To investigate the diagnostic efficacy of choline (Cho) value of magnetic resonance spectroscopy (MRS) in rabbit with VX2 liver tumor via comparative and quantitative analysis with the choline compounds concentration measured by enzyme linked immunosorbent assay (ELISA). Methods: MRS was...

Full description

Bibliographic Details
Main Authors: Ruikun Liao, Dan Zhang, Xiaojiao Li, Jiang Ma, Jiayi Yu, Chao Yang, Hua Xiong, Bi Zhou, Xianlong Huang, Zhuoyue Tang MD, PhD
Format: Article
Language:English
Published: SAGE Publishing 2021-08-01
Series:Technology in Cancer Research & Treatment
Online Access:https://doi.org/10.1177/15330338211036852
Description
Summary:Background: To investigate the diagnostic efficacy of choline (Cho) value of magnetic resonance spectroscopy (MRS) in rabbit with VX2 liver tumor via comparative and quantitative analysis with the choline compounds concentration measured by enzyme linked immunosorbent assay (ELISA). Methods: MRS was performed on normal liver and VX2 tumor. The Cho value of VX2 tumor was compared with that of normal liver. Tissues were harvested for ELISA to detect the concentrations of acetylcholine (ACh), glycophorophosphygholine (GPC) and phosphochorine (PC). The diagnostic performance of Cho value and concentrations of choline compounds were assessed by receiver operating characteristic (ROC) curve and area under ROC curve (AUC). The specificity and sensitivity were discussed by the maximum Youden’s index. Results: The concentration of ACh was obviously higher than that of GPC and PC both in VX2 tumor and normal liver ( P < 0.01). Furthermore, the concentration differences among ACh, GPC and PG were the third power of 10. Both the ACh concentration and Cho value of MRS in VX2 tumor were significantly higher than those in normal liver ( P < 0.01). The AUC of ACh in VX2 tumor was 0.883, when the cutoff value was 7259000, the sensitivity and specificity of the diagnosis of liver cancer were 94.4% and 77.8%, respectively. The AUC of Cho in VX2 tumor was 0.807, when the cutoff value was 28.35, the sensitivity and specificity of the diagnosis of liver cancer were 83.3% and 77.8%, respectively. Conclusion: The change of Cho value in MRS between liver cancer and normal liver was consistent with the changes of concentrations of choline compounds measured by ELISA, especially the change of ACh concentration. The diagnostic efficiency of Cho value and that of choline compounds concentration in liver cancer were extremely similar, with the AUC more than 0.8. We conclude that MRS may be applied as an important, non-invasive biomarker for the diagnosis of liver cancer.
ISSN:1533-0338