Development and validation of the enzymatic kinetic photometric procedure for determination of residual quantities of dequalinium chloride on the surface of the pharmaceutical equipment

Aim. To develop and validate the new enzymatic kinetic photometric procedure for analysis of dequalinium chloride based on application of enzymatic acetylcholine hydrolysis to determine the residual quantities of dequalinium chloride while monitoring the completeness of cleaning of the pharmaceutica...

Full description

Bibliographic Details
Main Authors: Mykola Ye. Blazheyevskiy, O. V. Kovalska, Ye. O. Tsapko, D. D. Shapovalenko
Format: Article
Language:English
Published: National University of Pharmacy (Kharkiv, Ukraine) 2019-09-01
Series:Журнал органічної та фармацевтичної хімії
Subjects:
Online Access:http://ophcj.nuph.edu.ua/article/view/ophcj.19.175500/177694
id doaj-2a4cc69a19da4bcf850ba3c5d5ff61c5
record_format Article
spelling doaj-2a4cc69a19da4bcf850ba3c5d5ff61c52020-11-25T04:07:56ZengNational University of Pharmacy (Kharkiv, Ukraine)Журнал органічної та фармацевтичної хімії2308-83032518-15482019-09-011733543https://doi.org/10.24959/ophcj.19.175500Development and validation of the enzymatic kinetic photometric procedure for determination of residual quantities of dequalinium chloride on the surface of the pharmaceutical equipmentMykola Ye. Blazheyevskiy0https://orcid.org/0000-0002-8032-347XO. V. Kovalska1Ye. O. Tsapko2D. D. Shapovalenko3National University of Pharmacy, UkraineNational University of Pharmacy UkraineNational University of Pharmacy UkraineNational University of Pharmacy UkraineAim. To develop and validate the new enzymatic kinetic photometric procedure for analysis of dequalinium chloride based on application of enzymatic acetylcholine hydrolysis to determine the residual quantities of dequalinium chloride while monitoring the completeness of cleaning of the pharmaceutical equipment. Results and discussion. The optimal conditions for the enzymatic reaction course were determined – the order of mixing and the concentration of acetylcholine (0.05 mg/mL), cholinesterase (0.4 mg/mL), hydrogen peroxide (10 %) and p-phenetedine (1 %), the time of the reaction mixture maintaining (20 min), pH (8.35), the effect of the nature of the buffer solution. Validation of the procedure developed was carried out – the application range of the procedure was proposed (40–160 % in the normalized coordinates, the maximum acceptable concentration of dequalinium chloride in washes from the pharmaceutical equipment хcrit = 0.5 μg/mL), the number of concentration levels (n = 7); the order of their location within the application range, taking these data into account the maximum acceptable uncertainty of the procedure (maxΔx = 3.05 %) and the acceptability criteria for linear dependence parameters, systematic and random errors were calculated. The validation characteristics of the procedure developed were shown to correspond to the acceptability criteria calculated. The degree of extraction of dequalinium chloride from swabs with flushing from the pharmaceutical equipment was determined. Experimental part. The residual quantities of dequalinium chloride on the surface of the pharmaceutical equipment were determined by the degree of inhibition of the enzymatic reaction assessed by the unreacted residue of the substrate of the biochemical reaction, such as acetylcholine. The residual quantities of acetylcholine in the reaction mixture was determined by the kinetic photometric method by the indicator reaction of p-phenetidine oxidation with peracetic acid (formed during the auxiliary perhydrolysis reaction when adding an excess of hydrogen peroxide to the reaction mixture) in the way of registering the light absorbance of the resulting reaction product – azoxifenetole (λmax = 358 nm) for a definite period of time. Conclusions. The enzymatic kinetic photometric procedure has been developed to determine the residual quantities of dequalinium chloride on the surface of the pharmaceutical equipment after its cleaning. The procedure developed has been validated by such parameters as linearity, accuracy, precision and the limit of quantification.http://ophcj.nuph.edu.ua/article/view/ophcj.19.175500/177694dequalinium chloridecholinesteraseacetylcholinevalidation
collection DOAJ
language English
format Article
sources DOAJ
author Mykola Ye. Blazheyevskiy
O. V. Kovalska
Ye. O. Tsapko
D. D. Shapovalenko
spellingShingle Mykola Ye. Blazheyevskiy
O. V. Kovalska
Ye. O. Tsapko
D. D. Shapovalenko
Development and validation of the enzymatic kinetic photometric procedure for determination of residual quantities of dequalinium chloride on the surface of the pharmaceutical equipment
Журнал органічної та фармацевтичної хімії
dequalinium chloride
cholinesterase
acetylcholine
validation
author_facet Mykola Ye. Blazheyevskiy
O. V. Kovalska
Ye. O. Tsapko
D. D. Shapovalenko
author_sort Mykola Ye. Blazheyevskiy
title Development and validation of the enzymatic kinetic photometric procedure for determination of residual quantities of dequalinium chloride on the surface of the pharmaceutical equipment
title_short Development and validation of the enzymatic kinetic photometric procedure for determination of residual quantities of dequalinium chloride on the surface of the pharmaceutical equipment
title_full Development and validation of the enzymatic kinetic photometric procedure for determination of residual quantities of dequalinium chloride on the surface of the pharmaceutical equipment
title_fullStr Development and validation of the enzymatic kinetic photometric procedure for determination of residual quantities of dequalinium chloride on the surface of the pharmaceutical equipment
title_full_unstemmed Development and validation of the enzymatic kinetic photometric procedure for determination of residual quantities of dequalinium chloride on the surface of the pharmaceutical equipment
title_sort development and validation of the enzymatic kinetic photometric procedure for determination of residual quantities of dequalinium chloride on the surface of the pharmaceutical equipment
publisher National University of Pharmacy (Kharkiv, Ukraine)
series Журнал органічної та фармацевтичної хімії
issn 2308-8303
2518-1548
publishDate 2019-09-01
description Aim. To develop and validate the new enzymatic kinetic photometric procedure for analysis of dequalinium chloride based on application of enzymatic acetylcholine hydrolysis to determine the residual quantities of dequalinium chloride while monitoring the completeness of cleaning of the pharmaceutical equipment. Results and discussion. The optimal conditions for the enzymatic reaction course were determined – the order of mixing and the concentration of acetylcholine (0.05 mg/mL), cholinesterase (0.4 mg/mL), hydrogen peroxide (10 %) and p-phenetedine (1 %), the time of the reaction mixture maintaining (20 min), pH (8.35), the effect of the nature of the buffer solution. Validation of the procedure developed was carried out – the application range of the procedure was proposed (40–160 % in the normalized coordinates, the maximum acceptable concentration of dequalinium chloride in washes from the pharmaceutical equipment хcrit = 0.5 μg/mL), the number of concentration levels (n = 7); the order of their location within the application range, taking these data into account the maximum acceptable uncertainty of the procedure (maxΔx = 3.05 %) and the acceptability criteria for linear dependence parameters, systematic and random errors were calculated. The validation characteristics of the procedure developed were shown to correspond to the acceptability criteria calculated. The degree of extraction of dequalinium chloride from swabs with flushing from the pharmaceutical equipment was determined. Experimental part. The residual quantities of dequalinium chloride on the surface of the pharmaceutical equipment were determined by the degree of inhibition of the enzymatic reaction assessed by the unreacted residue of the substrate of the biochemical reaction, such as acetylcholine. The residual quantities of acetylcholine in the reaction mixture was determined by the kinetic photometric method by the indicator reaction of p-phenetidine oxidation with peracetic acid (formed during the auxiliary perhydrolysis reaction when adding an excess of hydrogen peroxide to the reaction mixture) in the way of registering the light absorbance of the resulting reaction product – azoxifenetole (λmax = 358 nm) for a definite period of time. Conclusions. The enzymatic kinetic photometric procedure has been developed to determine the residual quantities of dequalinium chloride on the surface of the pharmaceutical equipment after its cleaning. The procedure developed has been validated by such parameters as linearity, accuracy, precision and the limit of quantification.
topic dequalinium chloride
cholinesterase
acetylcholine
validation
url http://ophcj.nuph.edu.ua/article/view/ophcj.19.175500/177694
work_keys_str_mv AT mykolayeblazheyevskiy developmentandvalidationoftheenzymatickineticphotometricprocedurefordeterminationofresidualquantitiesofdequaliniumchlorideonthesurfaceofthepharmaceuticalequipment
AT ovkovalska developmentandvalidationoftheenzymatickineticphotometricprocedurefordeterminationofresidualquantitiesofdequaliniumchlorideonthesurfaceofthepharmaceuticalequipment
AT yeotsapko developmentandvalidationoftheenzymatickineticphotometricprocedurefordeterminationofresidualquantitiesofdequaliniumchlorideonthesurfaceofthepharmaceuticalequipment
AT ddshapovalenko developmentandvalidationoftheenzymatickineticphotometricprocedurefordeterminationofresidualquantitiesofdequaliniumchlorideonthesurfaceofthepharmaceuticalequipment
_version_ 1724427349352513536