Performances and Reliability of Bruker Microflex LT and VITEK MS MALDI-TOF Mass Spectrometry Systems for the Identification of Clinical Microorganisms

In clinical microbiology laboratories, routine microbial identification is mostly performed using culture based methodologies requiring 24 to 72 hours from culturing to identification. Matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) technology has been est...

Full description

Bibliographic Details
Main Authors: Kivanc Bilecen, Gorkem Yaman, Ugur Ciftci, Yahya Rauf Laleli
Format: Article
Language:English
Published: Hindawi Limited 2015-01-01
Series:BioMed Research International
Online Access:http://dx.doi.org/10.1155/2015/516410
id doaj-2a73d71f74724ef995fd6deb25a0951a
record_format Article
spelling doaj-2a73d71f74724ef995fd6deb25a0951a2020-11-24T22:05:29ZengHindawi LimitedBioMed Research International2314-61332314-61412015-01-01201510.1155/2015/516410516410Performances and Reliability of Bruker Microflex LT and VITEK MS MALDI-TOF Mass Spectrometry Systems for the Identification of Clinical MicroorganismsKivanc Bilecen0Gorkem Yaman1Ugur Ciftci2Yahya Rauf Laleli3Department of Research & Development, Duzen Laboratories Group, 06680 Ankara, TurkeyDepartment of Clinical Microbiology, Duzen Laboratories Group, 34387 Istanbul, TurkeyDepartment of Clinical Microbiology, Duzen Laboratories Group, 06680 Ankara, TurkeyDepartment of Clinical Microbiology, Duzen Laboratories Group, 06680 Ankara, TurkeyIn clinical microbiology laboratories, routine microbial identification is mostly performed using culture based methodologies requiring 24 to 72 hours from culturing to identification. Matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) technology has been established as a cost effective, reliable, and faster alternative identification platform. In this study, we evaluated the reliability of the two available MALDI-TOF MS systems for their routine clinical level identification accuracy and efficiency in a clinical microbiology laboratory setting. A total of 1,341 routine phenotypically identified clinical bacterial and fungal isolates were selected and simultaneously analyzed using VITEK MS (bioMérieux, France) and Microflex LT (Bruker Diagnostics, Germany) MALDI-TOF MS systems. For any isolate that could not be identified with either of the systems and for any discordant result, 16S rDNA gene or ITS1/ITS2 sequencing was used. VITEK MS and Microflex LT correctly identified 1,303 (97.17%) and 1,298 (96.79%) isolates to the species level, respectively. In 114 (8.50%) isolates initial phenotypic identification was inaccurate. Both systems showed a similar identification efficiency and workflow robustness, and they were twice as more accurate compared to routine phenotypic identification in our sample pool. MALDITOF systems with their accuracy and robustness offer a good identification platform for routine clinical microbiology laboratories.http://dx.doi.org/10.1155/2015/516410
collection DOAJ
language English
format Article
sources DOAJ
author Kivanc Bilecen
Gorkem Yaman
Ugur Ciftci
Yahya Rauf Laleli
spellingShingle Kivanc Bilecen
Gorkem Yaman
Ugur Ciftci
Yahya Rauf Laleli
Performances and Reliability of Bruker Microflex LT and VITEK MS MALDI-TOF Mass Spectrometry Systems for the Identification of Clinical Microorganisms
BioMed Research International
author_facet Kivanc Bilecen
Gorkem Yaman
Ugur Ciftci
Yahya Rauf Laleli
author_sort Kivanc Bilecen
title Performances and Reliability of Bruker Microflex LT and VITEK MS MALDI-TOF Mass Spectrometry Systems for the Identification of Clinical Microorganisms
title_short Performances and Reliability of Bruker Microflex LT and VITEK MS MALDI-TOF Mass Spectrometry Systems for the Identification of Clinical Microorganisms
title_full Performances and Reliability of Bruker Microflex LT and VITEK MS MALDI-TOF Mass Spectrometry Systems for the Identification of Clinical Microorganisms
title_fullStr Performances and Reliability of Bruker Microflex LT and VITEK MS MALDI-TOF Mass Spectrometry Systems for the Identification of Clinical Microorganisms
title_full_unstemmed Performances and Reliability of Bruker Microflex LT and VITEK MS MALDI-TOF Mass Spectrometry Systems for the Identification of Clinical Microorganisms
title_sort performances and reliability of bruker microflex lt and vitek ms maldi-tof mass spectrometry systems for the identification of clinical microorganisms
publisher Hindawi Limited
series BioMed Research International
issn 2314-6133
2314-6141
publishDate 2015-01-01
description In clinical microbiology laboratories, routine microbial identification is mostly performed using culture based methodologies requiring 24 to 72 hours from culturing to identification. Matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) technology has been established as a cost effective, reliable, and faster alternative identification platform. In this study, we evaluated the reliability of the two available MALDI-TOF MS systems for their routine clinical level identification accuracy and efficiency in a clinical microbiology laboratory setting. A total of 1,341 routine phenotypically identified clinical bacterial and fungal isolates were selected and simultaneously analyzed using VITEK MS (bioMérieux, France) and Microflex LT (Bruker Diagnostics, Germany) MALDI-TOF MS systems. For any isolate that could not be identified with either of the systems and for any discordant result, 16S rDNA gene or ITS1/ITS2 sequencing was used. VITEK MS and Microflex LT correctly identified 1,303 (97.17%) and 1,298 (96.79%) isolates to the species level, respectively. In 114 (8.50%) isolates initial phenotypic identification was inaccurate. Both systems showed a similar identification efficiency and workflow robustness, and they were twice as more accurate compared to routine phenotypic identification in our sample pool. MALDITOF systems with their accuracy and robustness offer a good identification platform for routine clinical microbiology laboratories.
url http://dx.doi.org/10.1155/2015/516410
work_keys_str_mv AT kivancbilecen performancesandreliabilityofbrukermicroflexltandvitekmsmalditofmassspectrometrysystemsfortheidentificationofclinicalmicroorganisms
AT gorkemyaman performancesandreliabilityofbrukermicroflexltandvitekmsmalditofmassspectrometrysystemsfortheidentificationofclinicalmicroorganisms
AT ugurciftci performancesandreliabilityofbrukermicroflexltandvitekmsmalditofmassspectrometrysystemsfortheidentificationofclinicalmicroorganisms
AT yahyarauflaleli performancesandreliabilityofbrukermicroflexltandvitekmsmalditofmassspectrometrysystemsfortheidentificationofclinicalmicroorganisms
_version_ 1725826218624811008