A Comparison Between Novel FPGA-Based Pad Monitoring System Using Ballistocardiography and the Conventional Systems for Synchronization and Gating of CMRI at 3 Tesla: A Pilot Study

This pilot pre-clinical study demonstrates the applicability of a new type of pneumatic cardiac triggering (PCT) for cardiac imaging. The pilot research compares the novel FPGA-based pad monitoring system for cardiac triggering using ballistocardiography (BCG) with conventional systems based on elec...

Full description

Bibliographic Details
Main Authors: Radek Martinek, Jindrich Brablik, Jakub Kolarik, Martina Ladrova, Jan Nedoma, Radana Kahankova, Rene Jaros, Lubomir Vojtisek, Pavla Hanzlikova
Format: Article
Language:English
Published: IEEE 2020-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/8946605/
id doaj-2a7eaae9dfe74204a1eed79c7a7fc62a
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Radek Martinek
Jindrich Brablik
Jakub Kolarik
Martina Ladrova
Jan Nedoma
Radana Kahankova
Rene Jaros
Lubomir Vojtisek
Pavla Hanzlikova
spellingShingle Radek Martinek
Jindrich Brablik
Jakub Kolarik
Martina Ladrova
Jan Nedoma
Radana Kahankova
Rene Jaros
Lubomir Vojtisek
Pavla Hanzlikova
A Comparison Between Novel FPGA-Based Pad Monitoring System Using Ballistocardiography and the Conventional Systems for Synchronization and Gating of CMRI at 3 Tesla: A Pilot Study
IEEE Access
Cardiac triggering
triggering using ballistocardiography (BCG)
pad monitoring system
imaging of the heart
electrocardiography (ECG)
photoplethysmography (PPG)
author_facet Radek Martinek
Jindrich Brablik
Jakub Kolarik
Martina Ladrova
Jan Nedoma
Radana Kahankova
Rene Jaros
Lubomir Vojtisek
Pavla Hanzlikova
author_sort Radek Martinek
title A Comparison Between Novel FPGA-Based Pad Monitoring System Using Ballistocardiography and the Conventional Systems for Synchronization and Gating of CMRI at 3 Tesla: A Pilot Study
title_short A Comparison Between Novel FPGA-Based Pad Monitoring System Using Ballistocardiography and the Conventional Systems for Synchronization and Gating of CMRI at 3 Tesla: A Pilot Study
title_full A Comparison Between Novel FPGA-Based Pad Monitoring System Using Ballistocardiography and the Conventional Systems for Synchronization and Gating of CMRI at 3 Tesla: A Pilot Study
title_fullStr A Comparison Between Novel FPGA-Based Pad Monitoring System Using Ballistocardiography and the Conventional Systems for Synchronization and Gating of CMRI at 3 Tesla: A Pilot Study
title_full_unstemmed A Comparison Between Novel FPGA-Based Pad Monitoring System Using Ballistocardiography and the Conventional Systems for Synchronization and Gating of CMRI at 3 Tesla: A Pilot Study
title_sort comparison between novel fpga-based pad monitoring system using ballistocardiography and the conventional systems for synchronization and gating of cmri at 3 tesla: a pilot study
publisher IEEE
series IEEE Access
issn 2169-3536
publishDate 2020-01-01
description This pilot pre-clinical study demonstrates the applicability of a new type of pneumatic cardiac triggering (PCT) for cardiac imaging. The pilot research compares the novel FPGA-based pad monitoring system for cardiac triggering using ballistocardiography (BCG) with conventional systems based on electrocardiography (ECG) and photoplethysmography (PPG). The implemented system enables cardiac triggering without the need to fix the sensors to the patient's body. This unique approach has the potential to reduce the preparation time for examination and the examination itself and to increase patient's comfort. The pilot pre-clinical study was conducted on 10 subjects at the Siemens Prisma 3T MRI Scanner within the CEITEC Multimodal and Functional Imaging Laboratory - Central European Institute of Technology, Masaryk University, upon the approval of the Ethics Committee. In total, 748 peaks (heart beats) were detected, with 7.347 correctly identified as true positive peaks, 140 incorrectly detected as false positive peaks, and 106 missed peaks (false negative). For all subjects, the total accuracy reached 96.31% and F1 score reached 98.18%. The applicability of the proposed BCG system was also analyzed in terms of objective (BRISQUE, NIQE, PIQE) and subjective evaluation of the images by 10 experts. The study compares images from two basic cardiac sequences - TRUE FISP (Free Induction Decay Steady-State Precession) and PSIR (Phase Sensitive Inversion Recovery) sequences. The BCG system achieves comparable results with the most frequently used and most accurate clinical ECG system used as gold standard. The results prove that the BCG signal captured by our new sensor can be used as a substitute for ECG signal during MRI exam with reliability of 97%.
topic Cardiac triggering
triggering using ballistocardiography (BCG)
pad monitoring system
imaging of the heart
electrocardiography (ECG)
photoplethysmography (PPG)
url https://ieeexplore.ieee.org/document/8946605/
work_keys_str_mv AT radekmartinek acomparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT jindrichbrablik acomparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT jakubkolarik acomparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT martinaladrova acomparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT jannedoma acomparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT radanakahankova acomparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT renejaros acomparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT lubomirvojtisek acomparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT pavlahanzlikova acomparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT radekmartinek comparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT jindrichbrablik comparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT jakubkolarik comparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT martinaladrova comparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT jannedoma comparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT radanakahankova comparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT renejaros comparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT lubomirvojtisek comparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
AT pavlahanzlikova comparisonbetweennovelfpgabasedpadmonitoringsystemusingballistocardiographyandtheconventionalsystemsforsynchronizationandgatingofcmriat3teslaapilotstudy
_version_ 1724187460548689920
spelling doaj-2a7eaae9dfe74204a1eed79c7a7fc62a2021-03-30T01:10:59ZengIEEEIEEE Access2169-35362020-01-0184149417010.1109/ACCESS.2019.29632218946605A Comparison Between Novel FPGA-Based Pad Monitoring System Using Ballistocardiography and the Conventional Systems for Synchronization and Gating of CMRI at 3 Tesla: A Pilot StudyRadek Martinek0https://orcid.org/0000-0003-2054-143XJindrich Brablik1https://orcid.org/0000-0002-3430-7401Jakub Kolarik2https://orcid.org/0000-0001-9648-6225Martina Ladrova3https://orcid.org/0000-0002-5316-475XJan Nedoma4https://orcid.org/0000-0001-7459-2043Radana Kahankova5https://orcid.org/0000-0003-1555-9889Rene Jaros6https://orcid.org/0000-0003-3346-6467Lubomir Vojtisek7https://orcid.org/0000-0002-4027-6568Pavla Hanzlikova8https://orcid.org/0000-0003-0440-4187Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VŠB–Technical University of Ostrava, Ostrava, Czech RepublicDepartment of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VŠB–Technical University of Ostrava, Ostrava, Czech RepublicDepartment of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VŠB–Technical University of Ostrava, Ostrava, Czech RepublicDepartment of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VŠB–Technical University of Ostrava, Ostrava, Czech RepublicDepartment of Telecommunications, Faculty of Electrical Engineering and Computer Science, VŠB–Technical University of Ostrava, Ostrava, Czech RepublicDepartment of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VŠB–Technical University of Ostrava, Ostrava, Czech RepublicDepartment of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VŠB–Technical University of Ostrava, Ostrava, Czech RepublicCentral European Institute of Technology (CEITEC), Masaryk University, Ostrava, Czech RepublicDepartment of Imaging Method, Faculty of Medicine, University of Ostrava, Ostrava, Czech RepublicThis pilot pre-clinical study demonstrates the applicability of a new type of pneumatic cardiac triggering (PCT) for cardiac imaging. The pilot research compares the novel FPGA-based pad monitoring system for cardiac triggering using ballistocardiography (BCG) with conventional systems based on electrocardiography (ECG) and photoplethysmography (PPG). The implemented system enables cardiac triggering without the need to fix the sensors to the patient's body. This unique approach has the potential to reduce the preparation time for examination and the examination itself and to increase patient's comfort. The pilot pre-clinical study was conducted on 10 subjects at the Siemens Prisma 3T MRI Scanner within the CEITEC Multimodal and Functional Imaging Laboratory - Central European Institute of Technology, Masaryk University, upon the approval of the Ethics Committee. In total, 748 peaks (heart beats) were detected, with 7.347 correctly identified as true positive peaks, 140 incorrectly detected as false positive peaks, and 106 missed peaks (false negative). For all subjects, the total accuracy reached 96.31% and F1 score reached 98.18%. The applicability of the proposed BCG system was also analyzed in terms of objective (BRISQUE, NIQE, PIQE) and subjective evaluation of the images by 10 experts. The study compares images from two basic cardiac sequences - TRUE FISP (Free Induction Decay Steady-State Precession) and PSIR (Phase Sensitive Inversion Recovery) sequences. The BCG system achieves comparable results with the most frequently used and most accurate clinical ECG system used as gold standard. The results prove that the BCG signal captured by our new sensor can be used as a substitute for ECG signal during MRI exam with reliability of 97%.https://ieeexplore.ieee.org/document/8946605/Cardiac triggeringtriggering using ballistocardiography (BCG)pad monitoring systemimaging of the heartelectrocardiography (ECG)photoplethysmography (PPG)