Monitoring and Controlling Electric Power Stations Using GSM Network

This paper introduces a system design for monitoring and controls the components of power generation station and substation with help of existing communication link based on GSM network. In this design, a selected Programmable Logic Controller (PLC) connected to the fields that needed to be monitore...

Full description

Bibliographic Details
Main Authors: Goran Ismail, Bilal A. Mubdir, Asso Majeed, Asaad Mubdir Jassim Al-Hindawi
Format: Article
Language:English
Published: Sulaimani Polytechnic University 2019-10-01
Series:Kurdistan Journal of Applied Research
Subjects:
Online Access:http://kjar.spu.edu.iq/index.php/kjar/article/view/291
id doaj-2aaa4ebdaf0a4b56b14192ee86657cd6
record_format Article
spelling doaj-2aaa4ebdaf0a4b56b14192ee86657cd62020-11-25T01:25:07ZengSulaimani Polytechnic UniversityKurdistan Journal of Applied Research2411-76842411-77062019-10-0142808910.24017/science.2019.2.7291Monitoring and Controlling Electric Power Stations Using GSM NetworkGoran Ismail0Bilal A. Mubdir1Asso Majeed2Asaad Mubdir Jassim Al-Hindawi3Electrical Engineering Department, Faculty of Engineering, University of Sulaimani, Sulaimani, IraqCommunication Department, Technical Institute of Sulaimani, Sulaimani Polytechnic University, Sulaimani, IraqElectrical Engineering Department, Faculty of Engineering, University of Sulaimani, Sulaimani, IraqCommunication Engineering Department, Technical College of Engineering, Sulaimani Polytechnic University, Sulaimani, IraqThis paper introduces a system design for monitoring and controls the components of power generation station and substation with help of existing communication link based on GSM network. In this design, a selected Programmable Logic Controller (PLC) connected to the fields that needed to be monitored and continuously read changes in measurements of electrical parameters like voltage, current, bus bar circuit breakers…..etc.. These parameters have been monitored by PLC, on the base of conditions that PLC is programmed. PLC generates a text message and forward to other side; control center or mobile phone of engineer and technicians; who are responsible of monitoring. At control center, another GSM modem which has capability to connect with personal computer, receives that text massage using SMS and executes it. Software written with Vb.Net, works as Human Machine Interface (HMI) for this purpose. The system performance is acceptable in terms of errors in readings and time delay. The percentage error for the current is about 1%, and for the voltage is about 0.2%. The delivery time to receive new analog and digital inputs data is about 14.125 seconds, while the control of the circuit done after 4.68 seconds.http://kjar.spu.edu.iq/index.php/kjar/article/view/291gsm modem, hmi, plc, sensor, sms
collection DOAJ
language English
format Article
sources DOAJ
author Goran Ismail
Bilal A. Mubdir
Asso Majeed
Asaad Mubdir Jassim Al-Hindawi
spellingShingle Goran Ismail
Bilal A. Mubdir
Asso Majeed
Asaad Mubdir Jassim Al-Hindawi
Monitoring and Controlling Electric Power Stations Using GSM Network
Kurdistan Journal of Applied Research
gsm modem, hmi, plc, sensor, sms
author_facet Goran Ismail
Bilal A. Mubdir
Asso Majeed
Asaad Mubdir Jassim Al-Hindawi
author_sort Goran Ismail
title Monitoring and Controlling Electric Power Stations Using GSM Network
title_short Monitoring and Controlling Electric Power Stations Using GSM Network
title_full Monitoring and Controlling Electric Power Stations Using GSM Network
title_fullStr Monitoring and Controlling Electric Power Stations Using GSM Network
title_full_unstemmed Monitoring and Controlling Electric Power Stations Using GSM Network
title_sort monitoring and controlling electric power stations using gsm network
publisher Sulaimani Polytechnic University
series Kurdistan Journal of Applied Research
issn 2411-7684
2411-7706
publishDate 2019-10-01
description This paper introduces a system design for monitoring and controls the components of power generation station and substation with help of existing communication link based on GSM network. In this design, a selected Programmable Logic Controller (PLC) connected to the fields that needed to be monitored and continuously read changes in measurements of electrical parameters like voltage, current, bus bar circuit breakers…..etc.. These parameters have been monitored by PLC, on the base of conditions that PLC is programmed. PLC generates a text message and forward to other side; control center or mobile phone of engineer and technicians; who are responsible of monitoring. At control center, another GSM modem which has capability to connect with personal computer, receives that text massage using SMS and executes it. Software written with Vb.Net, works as Human Machine Interface (HMI) for this purpose. The system performance is acceptable in terms of errors in readings and time delay. The percentage error for the current is about 1%, and for the voltage is about 0.2%. The delivery time to receive new analog and digital inputs data is about 14.125 seconds, while the control of the circuit done after 4.68 seconds.
topic gsm modem, hmi, plc, sensor, sms
url http://kjar.spu.edu.iq/index.php/kjar/article/view/291
work_keys_str_mv AT goranismail monitoringandcontrollingelectricpowerstationsusinggsmnetwork
AT bilalamubdir monitoringandcontrollingelectricpowerstationsusinggsmnetwork
AT assomajeed monitoringandcontrollingelectricpowerstationsusinggsmnetwork
AT asaadmubdirjassimalhindawi monitoringandcontrollingelectricpowerstationsusinggsmnetwork
_version_ 1725115147010179072