Electrochemical Oxidation and Determination of Oxalic Acid at an Exfoliated Graphite-Polystyrene Composite Electrode

An exfoliated graphite-polystyrene composite electrode was evaluated as analternative electrode in the oxidation and the determination of oxalic acid in 0.1 M Na2SO4supporting electrolyte. Using CV, LSV, CA procedures, linear dependences I vs. C wereobtained in the concentrations range of oxalic aci...

Full description

Bibliographic Details
Main Authors: Joop Schoonman, Stephen Picken, Plamen Malchev, Georgeta Burtica, Aniela Pop, Ioana Corb, Ciprian Radovan, Florica Manea
Format: Article
Language:English
Published: MDPI AG 2007-04-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/7/4/615/
id doaj-2b458cfc18124d1990f6349ea3d6902b
record_format Article
spelling doaj-2b458cfc18124d1990f6349ea3d6902b2020-11-24T20:42:01ZengMDPI AGSensors1424-82202007-04-017461562710.3390/s7040615Electrochemical Oxidation and Determination of Oxalic Acid at an Exfoliated Graphite-Polystyrene Composite ElectrodeJoop SchoonmanStephen PickenPlamen MalchevGeorgeta BurticaAniela PopIoana CorbCiprian RadovanFlorica ManeaAn exfoliated graphite-polystyrene composite electrode was evaluated as analternative electrode in the oxidation and the determination of oxalic acid in 0.1 M Na2SO4supporting electrolyte. Using CV, LSV, CA procedures, linear dependences I vs. C wereobtained in the concentrations range of oxalic acid between 0.5 to 3 mM, with LOD =0.05mM, and recovery degree of 98%, without need of surface renewing between successiveruns. The accuracy of the methods was evaluated as excellent comparing the detection resultswith that obtained using conventional KMnO4 titration method. In addition, the apparentdiffusion coefficient of oxalic acid D was found to be around 2.89 · 10-8 cm2·s-1 by CA andCV.http://www.mdpi.com/1424-8220/7/4/615/exfoliated graphite-polystyrene composite electrodeoxalic acidelectrochemical oxidationelectrochemical determination
collection DOAJ
language English
format Article
sources DOAJ
author Joop Schoonman
Stephen Picken
Plamen Malchev
Georgeta Burtica
Aniela Pop
Ioana Corb
Ciprian Radovan
Florica Manea
spellingShingle Joop Schoonman
Stephen Picken
Plamen Malchev
Georgeta Burtica
Aniela Pop
Ioana Corb
Ciprian Radovan
Florica Manea
Electrochemical Oxidation and Determination of Oxalic Acid at an Exfoliated Graphite-Polystyrene Composite Electrode
Sensors
exfoliated graphite-polystyrene composite electrode
oxalic acid
electrochemical oxidation
electrochemical determination
author_facet Joop Schoonman
Stephen Picken
Plamen Malchev
Georgeta Burtica
Aniela Pop
Ioana Corb
Ciprian Radovan
Florica Manea
author_sort Joop Schoonman
title Electrochemical Oxidation and Determination of Oxalic Acid at an Exfoliated Graphite-Polystyrene Composite Electrode
title_short Electrochemical Oxidation and Determination of Oxalic Acid at an Exfoliated Graphite-Polystyrene Composite Electrode
title_full Electrochemical Oxidation and Determination of Oxalic Acid at an Exfoliated Graphite-Polystyrene Composite Electrode
title_fullStr Electrochemical Oxidation and Determination of Oxalic Acid at an Exfoliated Graphite-Polystyrene Composite Electrode
title_full_unstemmed Electrochemical Oxidation and Determination of Oxalic Acid at an Exfoliated Graphite-Polystyrene Composite Electrode
title_sort electrochemical oxidation and determination of oxalic acid at an exfoliated graphite-polystyrene composite electrode
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2007-04-01
description An exfoliated graphite-polystyrene composite electrode was evaluated as analternative electrode in the oxidation and the determination of oxalic acid in 0.1 M Na2SO4supporting electrolyte. Using CV, LSV, CA procedures, linear dependences I vs. C wereobtained in the concentrations range of oxalic acid between 0.5 to 3 mM, with LOD =0.05mM, and recovery degree of 98%, without need of surface renewing between successiveruns. The accuracy of the methods was evaluated as excellent comparing the detection resultswith that obtained using conventional KMnO4 titration method. In addition, the apparentdiffusion coefficient of oxalic acid D was found to be around 2.89 · 10-8 cm2·s-1 by CA andCV.
topic exfoliated graphite-polystyrene composite electrode
oxalic acid
electrochemical oxidation
electrochemical determination
url http://www.mdpi.com/1424-8220/7/4/615/
work_keys_str_mv AT joopschoonman electrochemicaloxidationanddeterminationofoxalicacidatanexfoliatedgraphitepolystyrenecompositeelectrode
AT stephenpicken electrochemicaloxidationanddeterminationofoxalicacidatanexfoliatedgraphitepolystyrenecompositeelectrode
AT plamenmalchev electrochemicaloxidationanddeterminationofoxalicacidatanexfoliatedgraphitepolystyrenecompositeelectrode
AT georgetaburtica electrochemicaloxidationanddeterminationofoxalicacidatanexfoliatedgraphitepolystyrenecompositeelectrode
AT anielapop electrochemicaloxidationanddeterminationofoxalicacidatanexfoliatedgraphitepolystyrenecompositeelectrode
AT ioanacorb electrochemicaloxidationanddeterminationofoxalicacidatanexfoliatedgraphitepolystyrenecompositeelectrode
AT ciprianradovan electrochemicaloxidationanddeterminationofoxalicacidatanexfoliatedgraphitepolystyrenecompositeelectrode
AT floricamanea electrochemicaloxidationanddeterminationofoxalicacidatanexfoliatedgraphitepolystyrenecompositeelectrode
_version_ 1716823542079684608