Investigation of LiF, Mg and Ti (TLD-100) Reproducibility

LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and t...

Full description

Bibliographic Details
Main Authors: Sadeghi M., Sina S., Faghihi R.
Format: Article
Language:English
Published: Shiraz University of Medical Sciences 2015-12-01
Series:Journal of Biomedical Physics and Engineering
Subjects:
LiF
Mg
ECC
Online Access:http://www.jbpe.org/Journal_OJS/JBPE/index.php/jbpe/article/view/290
id doaj-2c092215d374428eb982de3c6c51f715
record_format Article
spelling doaj-2c092215d374428eb982de3c6c51f7152020-11-24T23:30:19ZengShiraz University of Medical SciencesJournal of Biomedical Physics and Engineering2251-72002251-72002015-12-0154217222Investigation of LiF, Mg and Ti (TLD-100) ReproducibilitySadeghi M.0 Sina S.1Faghihi R.2Nuclear Engineering Department, School of Mechanical Engineering, Shiraz University, Shiraz, IranNuclear Engineering Department, School of Mechanical Engineering, Shiraz University, Shiraz, IranNuclear Engineering Department, School of Mechanical Engineering, Shiraz University, Shiraz, Iran | Radiation Research Center, School of Mechanical Engineering, Shiraz University, Shiraz, IranLiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses of 81 mGy (two times), 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.http://www.jbpe.org/Journal_OJS/JBPE/index.php/jbpe/article/view/290LiFMgand Ti; TLD-100ECC
collection DOAJ
language English
format Article
sources DOAJ
author Sadeghi M.
Sina S.
Faghihi R.
spellingShingle Sadeghi M.
Sina S.
Faghihi R.
Investigation of LiF, Mg and Ti (TLD-100) Reproducibility
Journal of Biomedical Physics and Engineering
LiF
Mg
and Ti; TLD-100
ECC
author_facet Sadeghi M.
Sina S.
Faghihi R.
author_sort Sadeghi M.
title Investigation of LiF, Mg and Ti (TLD-100) Reproducibility
title_short Investigation of LiF, Mg and Ti (TLD-100) Reproducibility
title_full Investigation of LiF, Mg and Ti (TLD-100) Reproducibility
title_fullStr Investigation of LiF, Mg and Ti (TLD-100) Reproducibility
title_full_unstemmed Investigation of LiF, Mg and Ti (TLD-100) Reproducibility
title_sort investigation of lif, mg and ti (tld-100) reproducibility
publisher Shiraz University of Medical Sciences
series Journal of Biomedical Physics and Engineering
issn 2251-7200
2251-7200
publishDate 2015-12-01
description LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses of 81 mGy (two times), 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.
topic LiF
Mg
and Ti; TLD-100
ECC
url http://www.jbpe.org/Journal_OJS/JBPE/index.php/jbpe/article/view/290
work_keys_str_mv AT sadeghim investigationoflifmgandtitld100reproducibility
AT sinas investigationoflifmgandtitld100reproducibility
AT faghihir investigationoflifmgandtitld100reproducibility
_version_ 1725541853208510464