Investigation of LiF, Mg and Ti (TLD-100) Reproducibility
LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and t...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Shiraz University of Medical Sciences
2015-12-01
|
Series: | Journal of Biomedical Physics and Engineering |
Subjects: | |
Online Access: | http://www.jbpe.org/Journal_OJS/JBPE/index.php/jbpe/article/view/290 |
id |
doaj-2c092215d374428eb982de3c6c51f715 |
---|---|
record_format |
Article |
spelling |
doaj-2c092215d374428eb982de3c6c51f7152020-11-24T23:30:19ZengShiraz University of Medical SciencesJournal of Biomedical Physics and Engineering2251-72002251-72002015-12-0154217222Investigation of LiF, Mg and Ti (TLD-100) ReproducibilitySadeghi M.0 Sina S.1Faghihi R.2Nuclear Engineering Department, School of Mechanical Engineering, Shiraz University, Shiraz, IranNuclear Engineering Department, School of Mechanical Engineering, Shiraz University, Shiraz, IranNuclear Engineering Department, School of Mechanical Engineering, Shiraz University, Shiraz, Iran | Radiation Research Center, School of Mechanical Engineering, Shiraz University, Shiraz, IranLiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses of 81 mGy (two times), 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.http://www.jbpe.org/Journal_OJS/JBPE/index.php/jbpe/article/view/290LiFMgand Ti; TLD-100ECC |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Sadeghi M. Sina S. Faghihi R. |
spellingShingle |
Sadeghi M. Sina S. Faghihi R. Investigation of LiF, Mg and Ti (TLD-100) Reproducibility Journal of Biomedical Physics and Engineering LiF Mg and Ti; TLD-100 ECC |
author_facet |
Sadeghi M. Sina S. Faghihi R. |
author_sort |
Sadeghi M. |
title |
Investigation of LiF, Mg and Ti (TLD-100) Reproducibility |
title_short |
Investigation of LiF, Mg and Ti (TLD-100) Reproducibility |
title_full |
Investigation of LiF, Mg and Ti (TLD-100) Reproducibility |
title_fullStr |
Investigation of LiF, Mg and Ti (TLD-100) Reproducibility |
title_full_unstemmed |
Investigation of LiF, Mg and Ti (TLD-100) Reproducibility |
title_sort |
investigation of lif, mg and ti (tld-100) reproducibility |
publisher |
Shiraz University of Medical Sciences |
series |
Journal of Biomedical Physics and Engineering |
issn |
2251-7200 2251-7200 |
publishDate |
2015-12-01 |
description |
LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry
purposes. The repeatability of TL dosimetry is investigated by exposing them to doses
of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical
TLD chips was randomly selected from a batch and the values of Element Correction
Coefficient (ECC) were obtained 4 times by irradiating them to doses of 81 mGy (two
times), 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility
of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do
not exceed 5%. |
topic |
LiF Mg and Ti; TLD-100 ECC |
url |
http://www.jbpe.org/Journal_OJS/JBPE/index.php/jbpe/article/view/290 |
work_keys_str_mv |
AT sadeghim investigationoflifmgandtitld100reproducibility AT sinas investigationoflifmgandtitld100reproducibility AT faghihir investigationoflifmgandtitld100reproducibility |
_version_ |
1725541853208510464 |