Water Stagnation and Flow Obstruction Reduces the Quality of Potable Water and Increases the Risk of Legionelloses

Legionella is an opportunistic waterborne pathogen associated with Legionnaires' disease and Pontiac fever. Despite improved public awareness, the incidence of Legionella associated infections has been increasing. Aerosols generated from engineered potable water systems are a demonstrated cause...

Full description

Bibliographic Details
Main Authors: Muhammad Atif Nisar, Kirstin E. Ross, Melissa H. Brown, Richard Bentham, Harriet Whiley
Format: Article
Language:English
Published: Frontiers Media S.A. 2020-12-01
Series:Frontiers in Environmental Science
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fenvs.2020.611611/full
id doaj-2cbe790964604dd1beaba86357187f1d
record_format Article
spelling doaj-2cbe790964604dd1beaba86357187f1d2020-12-14T06:32:42ZengFrontiers Media S.A.Frontiers in Environmental Science2296-665X2020-12-01810.3389/fenvs.2020.611611611611Water Stagnation and Flow Obstruction Reduces the Quality of Potable Water and Increases the Risk of LegionellosesMuhammad Atif NisarKirstin E. RossMelissa H. BrownRichard BenthamHarriet WhileyLegionella is an opportunistic waterborne pathogen associated with Legionnaires' disease and Pontiac fever. Despite improved public awareness, the incidence of Legionella associated infections has been increasing. Aerosols generated from engineered potable water systems are a demonstrated cause of both nosocomial and community-acquired legionellosis. The ecology of Legionella in these systems is complex with multiple factors impacting their colonization and persistence. Flow dynamics has been identified as an important factor and stagnation in cooling towers is an accepted risk for increased Legionella growth; however, less is known about the impact of flow dynamic on Legionella in potable water systems. This is especially complex due to the inherent intermittent and variable usage observed within outlets of a potable water system. This systematic literature review examines the role of fluid dynamics and stagnation on the colonization and growth of Legionella in potable water systems. Twenty two of 24 identified studies show a positive association between stagnation zones and increased colonization of Legionella. These zones included dead legs, dead ends, storage tanks, and obstructed water flow (such as intermittent usage or flow restriction). Prolonged stagnation in building plumbing systems also deteriorates the quality of thermally or chemically treated potable water. This stimulates the colonization of Legionella established biofilms. Such biofilms are intrinsically resistant to disinfection procedures and accelerate the rate of decay of chemical disinfectants. Sub-lethal doses of disinfectants and the presence of protozoan hosts in stationary water promote generation of viable but non-culturable Legionella cells. This results in false negatives in surveillance methods that use culture methodology. In conclusion, elimination of temporal and permanent stagnation points can improve the quality of potable water, efficacy of disinfectants, and reduce the risk of legionellosis. Current guidelines and water safety plans recognize the risks associated with permanent stagnation point (dead ends and dead legs); however, there is a need for greater emphasis on controlling temporal stagnation arising from intermittent usage.https://www.frontiersin.org/articles/10.3389/fenvs.2020.611611/fullLegionnaires' diseaselegionellosisbuildingplumbingwater stagnationflow dynamics
collection DOAJ
language English
format Article
sources DOAJ
author Muhammad Atif Nisar
Kirstin E. Ross
Melissa H. Brown
Richard Bentham
Harriet Whiley
spellingShingle Muhammad Atif Nisar
Kirstin E. Ross
Melissa H. Brown
Richard Bentham
Harriet Whiley
Water Stagnation and Flow Obstruction Reduces the Quality of Potable Water and Increases the Risk of Legionelloses
Frontiers in Environmental Science
Legionnaires' disease
legionellosis
building
plumbing
water stagnation
flow dynamics
author_facet Muhammad Atif Nisar
Kirstin E. Ross
Melissa H. Brown
Richard Bentham
Harriet Whiley
author_sort Muhammad Atif Nisar
title Water Stagnation and Flow Obstruction Reduces the Quality of Potable Water and Increases the Risk of Legionelloses
title_short Water Stagnation and Flow Obstruction Reduces the Quality of Potable Water and Increases the Risk of Legionelloses
title_full Water Stagnation and Flow Obstruction Reduces the Quality of Potable Water and Increases the Risk of Legionelloses
title_fullStr Water Stagnation and Flow Obstruction Reduces the Quality of Potable Water and Increases the Risk of Legionelloses
title_full_unstemmed Water Stagnation and Flow Obstruction Reduces the Quality of Potable Water and Increases the Risk of Legionelloses
title_sort water stagnation and flow obstruction reduces the quality of potable water and increases the risk of legionelloses
publisher Frontiers Media S.A.
series Frontiers in Environmental Science
issn 2296-665X
publishDate 2020-12-01
description Legionella is an opportunistic waterborne pathogen associated with Legionnaires' disease and Pontiac fever. Despite improved public awareness, the incidence of Legionella associated infections has been increasing. Aerosols generated from engineered potable water systems are a demonstrated cause of both nosocomial and community-acquired legionellosis. The ecology of Legionella in these systems is complex with multiple factors impacting their colonization and persistence. Flow dynamics has been identified as an important factor and stagnation in cooling towers is an accepted risk for increased Legionella growth; however, less is known about the impact of flow dynamic on Legionella in potable water systems. This is especially complex due to the inherent intermittent and variable usage observed within outlets of a potable water system. This systematic literature review examines the role of fluid dynamics and stagnation on the colonization and growth of Legionella in potable water systems. Twenty two of 24 identified studies show a positive association between stagnation zones and increased colonization of Legionella. These zones included dead legs, dead ends, storage tanks, and obstructed water flow (such as intermittent usage or flow restriction). Prolonged stagnation in building plumbing systems also deteriorates the quality of thermally or chemically treated potable water. This stimulates the colonization of Legionella established biofilms. Such biofilms are intrinsically resistant to disinfection procedures and accelerate the rate of decay of chemical disinfectants. Sub-lethal doses of disinfectants and the presence of protozoan hosts in stationary water promote generation of viable but non-culturable Legionella cells. This results in false negatives in surveillance methods that use culture methodology. In conclusion, elimination of temporal and permanent stagnation points can improve the quality of potable water, efficacy of disinfectants, and reduce the risk of legionellosis. Current guidelines and water safety plans recognize the risks associated with permanent stagnation point (dead ends and dead legs); however, there is a need for greater emphasis on controlling temporal stagnation arising from intermittent usage.
topic Legionnaires' disease
legionellosis
building
plumbing
water stagnation
flow dynamics
url https://www.frontiersin.org/articles/10.3389/fenvs.2020.611611/full
work_keys_str_mv AT muhammadatifnisar waterstagnationandflowobstructionreducesthequalityofpotablewaterandincreasestheriskoflegionelloses
AT kirstineross waterstagnationandflowobstructionreducesthequalityofpotablewaterandincreasestheriskoflegionelloses
AT melissahbrown waterstagnationandflowobstructionreducesthequalityofpotablewaterandincreasestheriskoflegionelloses
AT richardbentham waterstagnationandflowobstructionreducesthequalityofpotablewaterandincreasestheriskoflegionelloses
AT harrietwhiley waterstagnationandflowobstructionreducesthequalityofpotablewaterandincreasestheriskoflegionelloses
_version_ 1724383791371255808