Analisis Rugi-Rugi Panas pada Tangki Penyimpan Panas dalam Sistem Pembangkit Listrik Tenaga Matahari

<p>Analysis of heat loss on heat storage tank in solar power generation system is intended to determine the heat loss value during storage. Selection of insulation material, insulation thickness, time of storage and heat storage fluid affects the heat losses. The research was initiated by dete...

Full description

Bibliographic Details
Main Authors: Ghalya Pikra, Agus Salim, Tri Admono, Merry Indahsari Devi
Format: Article
Language:English
Published: Indonesian Institute of Sciences 2012-03-01
Series:Journal of Mechatronics, Electrical Power, and Vehicular Technology
Subjects:
Online Access:http://mevjournal.com/index.php/mev/article/view/3
id doaj-2ce83884eed944d1865cafe103a225c0
record_format Article
spelling doaj-2ce83884eed944d1865cafe103a225c02020-11-25T02:25:15ZengIndonesian Institute of SciencesJournal of Mechatronics, Electrical Power, and Vehicular Technology2087-33792088-69852012-03-0111131810.14203/j.mev.2010.v1.13-185Analisis Rugi-Rugi Panas pada Tangki Penyimpan Panas dalam Sistem Pembangkit Listrik Tenaga MatahariGhalya Pikra0Agus Salim1Tri Admono2Merry Indahsari Devi3Pusat Penelitian Tenaga Listrik dan Mekatronik - LIPI, Komplek LIPI, Jl. Cisitu No.21/154D, Bandung, Jawa Barat 40135Pusat Penelitian Tenaga Listrik dan Mekatronik - LIPI, Komplek LIPI, Jl. Cisitu No.21/154D, Bandung, Jawa Barat 40135Pusat Penelitian Tenaga Listrik dan Mekatronik - LIPI, Komplek LIPI, Jl. Cisitu No.21/154D, Bandung, Jawa Barat 40135Pusat Penelitian Tenaga Listrik dan Mekatronik - LIPI, Komplek LIPI, Jl. Cisitu No.21/154D, Bandung, Jawa Barat 40135<p>Analysis of heat loss on heat storage tank in solar power generation system is intended to determine the heat loss value during storage. Selection of insulation material, insulation thickness, time of storage and heat storage fluid affects the heat losses. The research was initiated by determining the dimension of the tank and its insulation material, and determining the heat storage time in the tank. Fluid and operating temperature is determined to get the fluid specification to be used as data analysis. The analysis begins with the calculation of storage capacities, followed by making of thermal nets to get the thermal resistance equation which is then used to calculate the heat loss in the tank. The result shows that the heat storage tank with 0.4 m diameter and 0.45 m height and uses ceramic fiber wool insulation with 0.1m thickness gives the value of heat loss of 63.43 W.</p><p> </p>http://mevjournal.com/index.php/mev/article/view/3Solar Power PlantsHeat Storage TankCeramicHeat Loss
collection DOAJ
language English
format Article
sources DOAJ
author Ghalya Pikra
Agus Salim
Tri Admono
Merry Indahsari Devi
spellingShingle Ghalya Pikra
Agus Salim
Tri Admono
Merry Indahsari Devi
Analisis Rugi-Rugi Panas pada Tangki Penyimpan Panas dalam Sistem Pembangkit Listrik Tenaga Matahari
Journal of Mechatronics, Electrical Power, and Vehicular Technology
Solar Power Plants
Heat Storage Tank
Ceramic
Heat Loss
author_facet Ghalya Pikra
Agus Salim
Tri Admono
Merry Indahsari Devi
author_sort Ghalya Pikra
title Analisis Rugi-Rugi Panas pada Tangki Penyimpan Panas dalam Sistem Pembangkit Listrik Tenaga Matahari
title_short Analisis Rugi-Rugi Panas pada Tangki Penyimpan Panas dalam Sistem Pembangkit Listrik Tenaga Matahari
title_full Analisis Rugi-Rugi Panas pada Tangki Penyimpan Panas dalam Sistem Pembangkit Listrik Tenaga Matahari
title_fullStr Analisis Rugi-Rugi Panas pada Tangki Penyimpan Panas dalam Sistem Pembangkit Listrik Tenaga Matahari
title_full_unstemmed Analisis Rugi-Rugi Panas pada Tangki Penyimpan Panas dalam Sistem Pembangkit Listrik Tenaga Matahari
title_sort analisis rugi-rugi panas pada tangki penyimpan panas dalam sistem pembangkit listrik tenaga matahari
publisher Indonesian Institute of Sciences
series Journal of Mechatronics, Electrical Power, and Vehicular Technology
issn 2087-3379
2088-6985
publishDate 2012-03-01
description <p>Analysis of heat loss on heat storage tank in solar power generation system is intended to determine the heat loss value during storage. Selection of insulation material, insulation thickness, time of storage and heat storage fluid affects the heat losses. The research was initiated by determining the dimension of the tank and its insulation material, and determining the heat storage time in the tank. Fluid and operating temperature is determined to get the fluid specification to be used as data analysis. The analysis begins with the calculation of storage capacities, followed by making of thermal nets to get the thermal resistance equation which is then used to calculate the heat loss in the tank. The result shows that the heat storage tank with 0.4 m diameter and 0.45 m height and uses ceramic fiber wool insulation with 0.1m thickness gives the value of heat loss of 63.43 W.</p><p> </p>
topic Solar Power Plants
Heat Storage Tank
Ceramic
Heat Loss
url http://mevjournal.com/index.php/mev/article/view/3
work_keys_str_mv AT ghalyapikra analisisrugirugipanaspadatangkipenyimpanpanasdalamsistempembangkitlistriktenagamatahari
AT agussalim analisisrugirugipanaspadatangkipenyimpanpanasdalamsistempembangkitlistriktenagamatahari
AT triadmono analisisrugirugipanaspadatangkipenyimpanpanasdalamsistempembangkitlistriktenagamatahari
AT merryindahsaridevi analisisrugirugipanaspadatangkipenyimpanpanasdalamsistempembangkitlistriktenagamatahari
_version_ 1724852285793632256