Dislodgment of VDD Lead Connected to DR Pacer and Managed by Mode Switch
An 80-year-old patient having a dual chamber DR pacer connected to a VDD lead presented with chronic lead dislodgment with the atrial ring displaced into the right ventricle. There was no ventricular capture at maximal ventricular output, and given the clinical settings, the condition was managed wi...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2012-01-01
|
Series: | Clinical Medicine Insights: Case Reports |
Online Access: | https://doi.org/10.4137/CCRep.S9625 |
id |
doaj-2fbc1b60473c4fdc84398b571ffb5bc4 |
---|---|
record_format |
Article |
spelling |
doaj-2fbc1b60473c4fdc84398b571ffb5bc42020-11-25T03:21:39ZengSAGE PublishingClinical Medicine Insights: Case Reports1179-54762012-01-01510.4137/CCRep.S9625Dislodgment of VDD Lead Connected to DR Pacer and Managed by Mode SwitchAntoine Kossaify0Nayla Nicolas1Electrophysiology Division, Cardiology department, USEK/NDS–-University Hospital, St. Charbel Street, Byblos, Lebanon.Electrophysiology Division, Cardiology department, USEK/NDS–-University Hospital, St. Charbel Street, Byblos, Lebanon.An 80-year-old patient having a dual chamber DR pacer connected to a VDD lead presented with chronic lead dislodgment with the atrial ring displaced into the right ventricle. There was no ventricular capture at maximal ventricular output, and given the clinical settings, the condition was managed with a conservative approach, the mode was switched to AAI ensuring a minimal adequate ventricular pacing backup in a non dependent patient.https://doi.org/10.4137/CCRep.S9625 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Antoine Kossaify Nayla Nicolas |
spellingShingle |
Antoine Kossaify Nayla Nicolas Dislodgment of VDD Lead Connected to DR Pacer and Managed by Mode Switch Clinical Medicine Insights: Case Reports |
author_facet |
Antoine Kossaify Nayla Nicolas |
author_sort |
Antoine Kossaify |
title |
Dislodgment of VDD Lead Connected to DR Pacer and Managed by Mode Switch |
title_short |
Dislodgment of VDD Lead Connected to DR Pacer and Managed by Mode Switch |
title_full |
Dislodgment of VDD Lead Connected to DR Pacer and Managed by Mode Switch |
title_fullStr |
Dislodgment of VDD Lead Connected to DR Pacer and Managed by Mode Switch |
title_full_unstemmed |
Dislodgment of VDD Lead Connected to DR Pacer and Managed by Mode Switch |
title_sort |
dislodgment of vdd lead connected to dr pacer and managed by mode switch |
publisher |
SAGE Publishing |
series |
Clinical Medicine Insights: Case Reports |
issn |
1179-5476 |
publishDate |
2012-01-01 |
description |
An 80-year-old patient having a dual chamber DR pacer connected to a VDD lead presented with chronic lead dislodgment with the atrial ring displaced into the right ventricle. There was no ventricular capture at maximal ventricular output, and given the clinical settings, the condition was managed with a conservative approach, the mode was switched to AAI ensuring a minimal adequate ventricular pacing backup in a non dependent patient. |
url |
https://doi.org/10.4137/CCRep.S9625 |
work_keys_str_mv |
AT antoinekossaify dislodgmentofvddleadconnectedtodrpacerandmanagedbymodeswitch AT naylanicolas dislodgmentofvddleadconnectedtodrpacerandmanagedbymodeswitch |
_version_ |
1724613512978759680 |