Racking resistance of prefabricated timber-glass wall elements
Importance of building large-size glazing into timber structures has significantly grown over the last decade. This was one of the major reasons for carrying out the presented experimental research on timber structures with a fixed glazing placed in the external sides or in the middle of the timberf...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institut za istrazivanja i projektovanja u privredi
2014-01-01
|
Series: | Istrazivanja i projektovanja za privredu |
Subjects: | |
Online Access: | https://scindeks-clanci.ceon.rs/data/pdf/1451-4117/2014/1451-41171401051P.pdf |
id |
doaj-306e4c49c2d546c092c77b019f480804 |
---|---|
record_format |
Article |
spelling |
doaj-306e4c49c2d546c092c77b019f4808042021-04-02T10:53:12ZengInstitut za istrazivanja i projektovanja u privrediIstrazivanja i projektovanja za privredu1451-41171821-31972014-01-0112151561451-41171401051PRacking resistance of prefabricated timber-glass wall elementsPremrov Miroslav0Ber Boštjan1Štrukelj Andrej2University of Maribor, Faculty of Civil Engineering, Maribor, SloveniaKager hiša DOO, Ptuj, SloveniaUniversity of Maribor, Faculty of Civil Engineering, Maribor, SloveniaImportance of building large-size glazing into timber structures has significantly grown over the last decade. This was one of the major reasons for carrying out the presented experimental research on timber structures with a fixed glazing placed in the external sides or in the middle of the timberframe wall elements. Timber frame, to which glass pane is directly attached, forms the composite wall element, which contributes to stability of the entire system with its load capacity. Different types of adhesives with specific characteristics were used and they consequently caused different impacts on a wall composite. Both concepts, with bilateral glass as well as single glass lining in the middle of profile, are presented.https://scindeks-clanci.ceon.rs/data/pdf/1451-4117/2014/1451-41171401051P.pdftimberglassresistancestabilityexperimentsmonotonic tests |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Premrov Miroslav Ber Boštjan Štrukelj Andrej |
spellingShingle |
Premrov Miroslav Ber Boštjan Štrukelj Andrej Racking resistance of prefabricated timber-glass wall elements Istrazivanja i projektovanja za privredu timber glass resistance stability experiments monotonic tests |
author_facet |
Premrov Miroslav Ber Boštjan Štrukelj Andrej |
author_sort |
Premrov Miroslav |
title |
Racking resistance of prefabricated timber-glass wall elements |
title_short |
Racking resistance of prefabricated timber-glass wall elements |
title_full |
Racking resistance of prefabricated timber-glass wall elements |
title_fullStr |
Racking resistance of prefabricated timber-glass wall elements |
title_full_unstemmed |
Racking resistance of prefabricated timber-glass wall elements |
title_sort |
racking resistance of prefabricated timber-glass wall elements |
publisher |
Institut za istrazivanja i projektovanja u privredi |
series |
Istrazivanja i projektovanja za privredu |
issn |
1451-4117 1821-3197 |
publishDate |
2014-01-01 |
description |
Importance of building large-size glazing into timber structures has significantly grown over the last decade. This was one of the major reasons for carrying out the presented experimental research on timber structures with a fixed glazing placed in the external sides or in the middle of the timberframe wall elements. Timber frame, to which glass pane is directly attached, forms the composite wall element, which contributes to stability of the entire system with its load capacity. Different types of adhesives with specific characteristics were used and they consequently caused different impacts on a wall composite. Both concepts, with bilateral glass as well as single glass lining in the middle of profile, are presented. |
topic |
timber glass resistance stability experiments monotonic tests |
url |
https://scindeks-clanci.ceon.rs/data/pdf/1451-4117/2014/1451-41171401051P.pdf |
work_keys_str_mv |
AT premrovmiroslav rackingresistanceofprefabricatedtimberglasswallelements AT berbostjan rackingresistanceofprefabricatedtimberglasswallelements AT strukeljandrej rackingresistanceofprefabricatedtimberglasswallelements |
_version_ |
1724166407137001472 |