Long-term clinical results and scanning electron microscopic analysis of the aspheric, hydrophobic, acrylic intraocular lens CT LUCIA 611P(Y)

Andreas F Borkenstein, Eva-Maria Borkenstein Borkenstein & Borkenstein, Privatklinik der Kreuzschwestern, Graz, Austria Purpose: The aim of this study was to evaluate the clinical outcomes of a novel designed hydrophobic, acrylic, monofocal, fully preloaded intraocular lens (IOL; CT LUCIA...

Full description

Bibliographic Details
Main Authors: Borkenstein AF, Borkenstein EM
Format: Article
Language:English
Published: Dove Medical Press 2018-07-01
Series:Clinical Ophthalmology
Subjects:
IOL
Online Access:https://www.dovepress.com/long-term-clinical-results-and-scanning-electron-microscopic-analysis--peer-reviewed-article-OPTH
id doaj-31659e9656ab4bdda223580976b88e1c
record_format Article
spelling doaj-31659e9656ab4bdda223580976b88e1c2020-11-24T21:11:11ZengDove Medical PressClinical Ophthalmology1177-54832018-07-01Volume 121219122739178Long-term clinical results and scanning electron microscopic analysis of the aspheric, hydrophobic, acrylic intraocular lens CT LUCIA 611P(Y)Borkenstein AFBorkenstein EMAndreas F Borkenstein, Eva-Maria Borkenstein Borkenstein & Borkenstein, Privatklinik der Kreuzschwestern, Graz, Austria Purpose: The aim of this study was to evaluate the clinical outcomes of a novel designed hydrophobic, acrylic, monofocal, fully preloaded intraocular lens (IOL; CT LUCIA 611P) 1 year after implantation. Scanning electron microscopic analysis regarding the optic–haptic junction and sharp edges of the IOL was performed. Patients and methods: This is a noninterventional, observational prospective study of cataract patients who underwent implantation of the CT LUCIA 611P. Ninety-six eyes of 54 subjects were enrolled. Follow-up included visual acuity assessment, slit lamp examination with special focus on appearance of glistenings and evaluation of posterior capsule opacification (PCO). Scanning electron microscopic analysis of the new designed optic–haptic junction and edges of the IOL was performed. Results: Best-corrected distance visual acuity increased from mean 0.48 logMAR (range 0.86–0.34) preoperatively to mean 0.02 logMAR (range 0.14 to -0.10) 1 year after surgery. Thirty-eight of 42 subjects’ eyes (90.5%), which underwent bilateral surgery with implantation of the IOL, never required glasses for distance again, while 4 (9.5%) required glasses only in rare cases (eg, driving at night). The spherical equivalent was within ±0.50 D in 88 of 96 subjects (91.7%) and within ±0.75 D in 96.9% of cases. Target refraction ±1.00 D was achieved in 100% of subject eyes. No glistenings were reported in any case. From the surgeons’ perspective, the wider, thicker optic–haptic transition of the IOL resulted in significantly increased stiffness, which enabled improved centering of the IOL and enhanced rotational stability and refractive predictability and stability and PCO prevention. Conclusion: The results of this long-term observational study demonstrate the safety and efficacy of the IOL. Because of the completely new designed thicker and stiffer optic–haptic junction regarding improved characteristics of the IOL (stability in the capsular bag), some special attention has to be addressed to the slightly different behavior of the lens during implantation and unfolding process. Keywords: intraocular lens, IOL, CT LUCIA 611P(Y), cataract surgery, quality of vision, aspheric design, glistenings, square edge, Achilles Heel of the IOLhttps://www.dovepress.com/long-term-clinical-results-and-scanning-electron-microscopic-analysis--peer-reviewed-article-OPTHIntraocular lensIOLCT LUCIA 611P(Y)cataract surgeryquality of visionaspheric designglisteningssquare edgeAchilles Heel of the IOL
collection DOAJ
language English
format Article
sources DOAJ
author Borkenstein AF
Borkenstein EM
spellingShingle Borkenstein AF
Borkenstein EM
Long-term clinical results and scanning electron microscopic analysis of the aspheric, hydrophobic, acrylic intraocular lens CT LUCIA 611P(Y)
Clinical Ophthalmology
Intraocular lens
IOL
CT LUCIA 611P(Y)
cataract surgery
quality of vision
aspheric design
glistenings
square edge
Achilles Heel of the IOL
author_facet Borkenstein AF
Borkenstein EM
author_sort Borkenstein AF
title Long-term clinical results and scanning electron microscopic analysis of the aspheric, hydrophobic, acrylic intraocular lens CT LUCIA 611P(Y)
title_short Long-term clinical results and scanning electron microscopic analysis of the aspheric, hydrophobic, acrylic intraocular lens CT LUCIA 611P(Y)
title_full Long-term clinical results and scanning electron microscopic analysis of the aspheric, hydrophobic, acrylic intraocular lens CT LUCIA 611P(Y)
title_fullStr Long-term clinical results and scanning electron microscopic analysis of the aspheric, hydrophobic, acrylic intraocular lens CT LUCIA 611P(Y)
title_full_unstemmed Long-term clinical results and scanning electron microscopic analysis of the aspheric, hydrophobic, acrylic intraocular lens CT LUCIA 611P(Y)
title_sort long-term clinical results and scanning electron microscopic analysis of the aspheric, hydrophobic, acrylic intraocular lens ct lucia 611p(y)
publisher Dove Medical Press
series Clinical Ophthalmology
issn 1177-5483
publishDate 2018-07-01
description Andreas F Borkenstein, Eva-Maria Borkenstein Borkenstein & Borkenstein, Privatklinik der Kreuzschwestern, Graz, Austria Purpose: The aim of this study was to evaluate the clinical outcomes of a novel designed hydrophobic, acrylic, monofocal, fully preloaded intraocular lens (IOL; CT LUCIA 611P) 1 year after implantation. Scanning electron microscopic analysis regarding the optic–haptic junction and sharp edges of the IOL was performed. Patients and methods: This is a noninterventional, observational prospective study of cataract patients who underwent implantation of the CT LUCIA 611P. Ninety-six eyes of 54 subjects were enrolled. Follow-up included visual acuity assessment, slit lamp examination with special focus on appearance of glistenings and evaluation of posterior capsule opacification (PCO). Scanning electron microscopic analysis of the new designed optic–haptic junction and edges of the IOL was performed. Results: Best-corrected distance visual acuity increased from mean 0.48 logMAR (range 0.86–0.34) preoperatively to mean 0.02 logMAR (range 0.14 to -0.10) 1 year after surgery. Thirty-eight of 42 subjects’ eyes (90.5%), which underwent bilateral surgery with implantation of the IOL, never required glasses for distance again, while 4 (9.5%) required glasses only in rare cases (eg, driving at night). The spherical equivalent was within ±0.50 D in 88 of 96 subjects (91.7%) and within ±0.75 D in 96.9% of cases. Target refraction ±1.00 D was achieved in 100% of subject eyes. No glistenings were reported in any case. From the surgeons’ perspective, the wider, thicker optic–haptic transition of the IOL resulted in significantly increased stiffness, which enabled improved centering of the IOL and enhanced rotational stability and refractive predictability and stability and PCO prevention. Conclusion: The results of this long-term observational study demonstrate the safety and efficacy of the IOL. Because of the completely new designed thicker and stiffer optic–haptic junction regarding improved characteristics of the IOL (stability in the capsular bag), some special attention has to be addressed to the slightly different behavior of the lens during implantation and unfolding process. Keywords: intraocular lens, IOL, CT LUCIA 611P(Y), cataract surgery, quality of vision, aspheric design, glistenings, square edge, Achilles Heel of the IOL
topic Intraocular lens
IOL
CT LUCIA 611P(Y)
cataract surgery
quality of vision
aspheric design
glistenings
square edge
Achilles Heel of the IOL
url https://www.dovepress.com/long-term-clinical-results-and-scanning-electron-microscopic-analysis--peer-reviewed-article-OPTH
work_keys_str_mv AT borkensteinaf longtermclinicalresultsandscanningelectronmicroscopicanalysisoftheaspherichydrophobicacrylicintraocularlensctlucia611py
AT borkensteinem longtermclinicalresultsandscanningelectronmicroscopicanalysisoftheaspherichydrophobicacrylicintraocularlensctlucia611py
_version_ 1716754203325497344