Measurement of Aortic Root Dimensions by Transthoracic Echocardiogram in Normal Indian Population

Background: Aortic root dimension varies on the basis of age, body surface area, ethnicity, and in pathological states such as bicuspid aortic valve and connective tissue disorders. Aim: This observational study has been done to determine aortic root dimension in normal Indian population. In this st...

Full description

Bibliographic Details
Main Authors: S Venkatesan, G Prathap Kumar, Deepak Nenwani, N Swaminathan, G Ravi Shankar, G Justin Paul
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2020-01-01
Series:Journal of the Indian Academy of Echocardiography & Cardiovascular Imaging
Subjects:
Online Access:http://www.jiaecho.org/article.asp?issn=2543-1463;year=2020;volume=4;issue=2;spage=168;epage=170;aulast=Venkatesan
id doaj-31c5c1e7225f420fb7b71fea7f1ec9f3
record_format Article
spelling doaj-31c5c1e7225f420fb7b71fea7f1ec9f32021-08-20T06:09:47ZengWolters Kluwer Medknow PublicationsJournal of the Indian Academy of Echocardiography & Cardiovascular Imaging2543-14632543-14712020-01-014216817010.4103/jiae.jiae_7_20Measurement of Aortic Root Dimensions by Transthoracic Echocardiogram in Normal Indian PopulationS VenkatesanG Prathap KumarDeepak NenwaniN SwaminathanG Ravi ShankarG Justin PaulBackground: Aortic root dimension varies on the basis of age, body surface area, ethnicity, and in pathological states such as bicuspid aortic valve and connective tissue disorders. Aim: This observational study has been done to determine aortic root dimension in normal Indian population. In this study, aortic root dimensions were measured by two-dimensional (2D) echocardiography in parasternal long axis (PLAX) view by inner edge to inner edge method. Materials and Methods: Clinically normal Indian population was prospectively recruited. All participants were asymptomatic. All echocardiographic measurements were done twice and image acquired by single observer on the same machine. Aortic root dimensions measurements were done with 2D echo in PLAX view at 4-level aortic annulus, sinus of Valsalva, sinotubular junction, and proximal ascending aorta. Results: Aortic annulus does not show any significant correlation with age. Age parameter shows a significant correlation with the ascending aorta and sinus, sino-tubular (ST) junction. Weight parameter shows a significant correlation with annulus, sinus, and ST junction. Height parameter shows a significant correlation with all aortic dimensions. Conclusion: Indian patient has different body surface area than the Western population; therefore, there is a need of standard normal aortogram dimension for normal Indian population.http://www.jiaecho.org/article.asp?issn=2543-1463;year=2020;volume=4;issue=2;spage=168;epage=170;aulast=Venkatesanaortic root dimensioninner edge to inner edge measurementnormal indian population
collection DOAJ
language English
format Article
sources DOAJ
author S Venkatesan
G Prathap Kumar
Deepak Nenwani
N Swaminathan
G Ravi Shankar
G Justin Paul
spellingShingle S Venkatesan
G Prathap Kumar
Deepak Nenwani
N Swaminathan
G Ravi Shankar
G Justin Paul
Measurement of Aortic Root Dimensions by Transthoracic Echocardiogram in Normal Indian Population
Journal of the Indian Academy of Echocardiography & Cardiovascular Imaging
aortic root dimension
inner edge to inner edge measurement
normal indian population
author_facet S Venkatesan
G Prathap Kumar
Deepak Nenwani
N Swaminathan
G Ravi Shankar
G Justin Paul
author_sort S Venkatesan
title Measurement of Aortic Root Dimensions by Transthoracic Echocardiogram in Normal Indian Population
title_short Measurement of Aortic Root Dimensions by Transthoracic Echocardiogram in Normal Indian Population
title_full Measurement of Aortic Root Dimensions by Transthoracic Echocardiogram in Normal Indian Population
title_fullStr Measurement of Aortic Root Dimensions by Transthoracic Echocardiogram in Normal Indian Population
title_full_unstemmed Measurement of Aortic Root Dimensions by Transthoracic Echocardiogram in Normal Indian Population
title_sort measurement of aortic root dimensions by transthoracic echocardiogram in normal indian population
publisher Wolters Kluwer Medknow Publications
series Journal of the Indian Academy of Echocardiography & Cardiovascular Imaging
issn 2543-1463
2543-1471
publishDate 2020-01-01
description Background: Aortic root dimension varies on the basis of age, body surface area, ethnicity, and in pathological states such as bicuspid aortic valve and connective tissue disorders. Aim: This observational study has been done to determine aortic root dimension in normal Indian population. In this study, aortic root dimensions were measured by two-dimensional (2D) echocardiography in parasternal long axis (PLAX) view by inner edge to inner edge method. Materials and Methods: Clinically normal Indian population was prospectively recruited. All participants were asymptomatic. All echocardiographic measurements were done twice and image acquired by single observer on the same machine. Aortic root dimensions measurements were done with 2D echo in PLAX view at 4-level aortic annulus, sinus of Valsalva, sinotubular junction, and proximal ascending aorta. Results: Aortic annulus does not show any significant correlation with age. Age parameter shows a significant correlation with the ascending aorta and sinus, sino-tubular (ST) junction. Weight parameter shows a significant correlation with annulus, sinus, and ST junction. Height parameter shows a significant correlation with all aortic dimensions. Conclusion: Indian patient has different body surface area than the Western population; therefore, there is a need of standard normal aortogram dimension for normal Indian population.
topic aortic root dimension
inner edge to inner edge measurement
normal indian population
url http://www.jiaecho.org/article.asp?issn=2543-1463;year=2020;volume=4;issue=2;spage=168;epage=170;aulast=Venkatesan
work_keys_str_mv AT svenkatesan measurementofaorticrootdimensionsbytransthoracicechocardiograminnormalindianpopulation
AT gprathapkumar measurementofaorticrootdimensionsbytransthoracicechocardiograminnormalindianpopulation
AT deepaknenwani measurementofaorticrootdimensionsbytransthoracicechocardiograminnormalindianpopulation
AT nswaminathan measurementofaorticrootdimensionsbytransthoracicechocardiograminnormalindianpopulation
AT gravishankar measurementofaorticrootdimensionsbytransthoracicechocardiograminnormalindianpopulation
AT gjustinpaul measurementofaorticrootdimensionsbytransthoracicechocardiograminnormalindianpopulation
_version_ 1721201381394612224