Recognition of the noise sources and measurement in educational hospital s General Intensive Care Unit (GICU)

Background and Aim: Noise is the most common source of environmental stress that influences negatively the psychological and physiological aspects of human. The purpose of this study was determining the noise sources and assessing in General Intensive Care Unit. Materials and Methods: In this cros...

Full description

Bibliographic Details
Main Authors: Vahideh Abolhasannejad, Narjess Moasheri, Mansour Soltani, Faezeh Shirazi
Format: Article
Language:fas
Published: Birjand University of Medical Sciences and Health Services 2014-11-01
Series:Journal of Birjand University of Medical Sciences
Subjects:
Online Access:http://journal.bums.ac.ir/browse.php?a_code=A-10-670-2&slc_lang=en&sid=1
id doaj-31eaccc1e116429a821dd449a5aa90e3
record_format Article
spelling doaj-31eaccc1e116429a821dd449a5aa90e32020-11-25T01:12:47ZfasBirjand University of Medical Sciences and Health ServicesJournal of Birjand University of Medical Sciences1607-21972423-61522014-11-01213362369Recognition of the noise sources and measurement in educational hospital s General Intensive Care Unit (GICU)Vahideh Abolhasannejad0Narjess Moasheri1Mansour Soltani2Faezeh Shirazi3 Department of occupational Health Engineering , School of Public Health and, Social Determinant of Health Research Center, Birjand University of Medical Sciences, Birjand, Iran MSc of community health, School of Public Health, and Social Determinant of Health Research Center, Birjand University of Medical Sciences, Birjand, Iran Faculty Paramedical, Birjand University of Medical Sciences, Birjand, Iran Students' Research Center, Bs students of paramedical faculty, Birjand University of Medical Sciences, Birjand, Iran Background and Aim: Noise is the most common source of environmental stress that influences negatively the psychological and physiological aspects of human. The purpose of this study was determining the noise sources and assessing in General Intensive Care Unit. Materials and Methods: In this cross-sectional study, equivalent noise level "Leq 15 min", Maximum and Minimum sound pressure level were measured on 5 stations, during the all of day and night shifts period in different place including corridor, nursing station, rest room and hospitalization parts. The data were processed by means of SPSS and Excel software. Results: Mean sound pressure level for GICU was 60.9±1/6 dBA that is more than the standard level. The mean of maximum noise level was obtained 82.5±2 dBA and the highest noise level was measured at nursing station. There was significant difference in Noise Pollution level based on different months, level of patient's conciseness and number of ventilator using (P < 0.05). Conclusion: Being more noise pollution in the ICU and stations on all shifts may cause to diminish health and well-being of the staff in long-term and produce some problems for the patient. According to the highest level of noise produced in nursing stations and the different activities doing by the staff as a main noise pollution factor, it's necessary to perform required training in relationship with doing the works in right manner so that we can produce quiet and silence environment for patience.http://journal.bums.ac.ir/browse.php?a_code=A-10-670-2&slc_lang=en&sid=1Noise Measurement Intensive Care Unit Maximum Noise Level
collection DOAJ
language fas
format Article
sources DOAJ
author Vahideh Abolhasannejad
Narjess Moasheri
Mansour Soltani
Faezeh Shirazi
spellingShingle Vahideh Abolhasannejad
Narjess Moasheri
Mansour Soltani
Faezeh Shirazi
Recognition of the noise sources and measurement in educational hospital s General Intensive Care Unit (GICU)
Journal of Birjand University of Medical Sciences
Noise Measurement
Intensive Care Unit
Maximum Noise Level
author_facet Vahideh Abolhasannejad
Narjess Moasheri
Mansour Soltani
Faezeh Shirazi
author_sort Vahideh Abolhasannejad
title Recognition of the noise sources and measurement in educational hospital s General Intensive Care Unit (GICU)
title_short Recognition of the noise sources and measurement in educational hospital s General Intensive Care Unit (GICU)
title_full Recognition of the noise sources and measurement in educational hospital s General Intensive Care Unit (GICU)
title_fullStr Recognition of the noise sources and measurement in educational hospital s General Intensive Care Unit (GICU)
title_full_unstemmed Recognition of the noise sources and measurement in educational hospital s General Intensive Care Unit (GICU)
title_sort recognition of the noise sources and measurement in educational hospital s general intensive care unit (gicu)
publisher Birjand University of Medical Sciences and Health Services
series Journal of Birjand University of Medical Sciences
issn 1607-2197
2423-6152
publishDate 2014-11-01
description Background and Aim: Noise is the most common source of environmental stress that influences negatively the psychological and physiological aspects of human. The purpose of this study was determining the noise sources and assessing in General Intensive Care Unit. Materials and Methods: In this cross-sectional study, equivalent noise level "Leq 15 min", Maximum and Minimum sound pressure level were measured on 5 stations, during the all of day and night shifts period in different place including corridor, nursing station, rest room and hospitalization parts. The data were processed by means of SPSS and Excel software. Results: Mean sound pressure level for GICU was 60.9±1/6 dBA that is more than the standard level. The mean of maximum noise level was obtained 82.5±2 dBA and the highest noise level was measured at nursing station. There was significant difference in Noise Pollution level based on different months, level of patient's conciseness and number of ventilator using (P < 0.05). Conclusion: Being more noise pollution in the ICU and stations on all shifts may cause to diminish health and well-being of the staff in long-term and produce some problems for the patient. According to the highest level of noise produced in nursing stations and the different activities doing by the staff as a main noise pollution factor, it's necessary to perform required training in relationship with doing the works in right manner so that we can produce quiet and silence environment for patience.
topic Noise Measurement
Intensive Care Unit
Maximum Noise Level
url http://journal.bums.ac.ir/browse.php?a_code=A-10-670-2&slc_lang=en&sid=1
work_keys_str_mv AT vahidehabolhasannejad recognitionofthenoisesourcesandmeasurementineducationalhospitalsgeneralintensivecareunitgicu
AT narjessmoasheri recognitionofthenoisesourcesandmeasurementineducationalhospitalsgeneralintensivecareunitgicu
AT mansoursoltani recognitionofthenoisesourcesandmeasurementineducationalhospitalsgeneralintensivecareunitgicu
AT faezehshirazi recognitionofthenoisesourcesandmeasurementineducationalhospitalsgeneralintensivecareunitgicu
_version_ 1725164996532371456