Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device
The aim of the current study was to assess efficacy and safety of ab interno trabeculectomy surgery applied with trabectome device in early period. The study was designed among the 30 eyes of 26 patients who had undergone trabectome surgery with the diagnosis of open-angle glaucoma. Patients were ev...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Society of TURAZ AKADEMI
2017-03-01
|
Series: | Medicine Science |
Subjects: | |
Online Access: | http://www.ejmanager.com/fulltextpdf.php?mno=232252 |
id |
doaj-329225b65a694df384002105706e89e7 |
---|---|
record_format |
Article |
spelling |
doaj-329225b65a694df384002105706e89e72020-11-24T21:22:23ZengSociety of TURAZ AKADEMI Medicine Science2147-06342017-03-016111610.5455/medscience.2016.05.8501232252Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome deviceEyup Duzgun0Yildiray Yildirim1Akin Cakir2Melih Hamdi Unal3Ali Ayata4Murat Sonmez5Gumussuyu Military Hospital, Department of Ophthalmology, Beyoglu, Istanbul, Turkey. Gulhane Military Medical Academy Haydarpasa Training Hospital, Department of Ophthalmology, Istanbul, Turkey. Kasimpasa Military Hospital, Department of Ophthalmology, Beyoglu, Istanbul, Turkey Gulhane Military Medical Academy Haydarpasa Training Hospital, Department of Ophthalmology, Istanbul, Turkey. Gulhane Military Medical Academy Haydarpasa Training Hospital, Department of Ophthalmology, Istanbul, Turkey. Gulhane Military Medical Academy Haydarpasa Training Hospital, Department of Ophthalmology, Istanbul, Turkey.The aim of the current study was to assess efficacy and safety of ab interno trabeculectomy surgery applied with trabectome device in early period. The study was designed among the 30 eyes of 26 patients who had undergone trabectome surgery with the diagnosis of open-angle glaucoma. Patients were evaluated as retrospectively in terms of preoperative and postoperative intraocular pressure (IOP), number of drugs used and complications. While the preoperative mean IOP was 28.78±5.57 mmHg (n:30) with the mean number of medications 3.40±1.04, the mean IOP was 18.24±5.54 mmHg (n:30) with the mean number of medications 0.90±1.27 at 1st month. At 3rd month the mean IOP was 16.37±3.36 mmHg (n:28) with the mean number of medications 0.70±1.10 and at 6th month the mean IOP was 16.51±3.80 mmHg (n:28) with the mean number of medications 1.13±0.96. When postoperative measurements compared with preoperative values, detected reductions in IOP and number of medications were statistically significant (P [Med-Science 2017; 6(1.000): 11-6]http://www.ejmanager.com/fulltextpdf.php?mno=232252Trabectome surgeryopen angle glaucomaminimally invasive glaucoma surgery |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Eyup Duzgun Yildiray Yildirim Akin Cakir Melih Hamdi Unal Ali Ayata Murat Sonmez |
spellingShingle |
Eyup Duzgun Yildiray Yildirim Akin Cakir Melih Hamdi Unal Ali Ayata Murat Sonmez Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device Medicine Science Trabectome surgery open angle glaucoma minimally invasive glaucoma surgery |
author_facet |
Eyup Duzgun Yildiray Yildirim Akin Cakir Melih Hamdi Unal Ali Ayata Murat Sonmez |
author_sort |
Eyup Duzgun |
title |
Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device |
title_short |
Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device |
title_full |
Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device |
title_fullStr |
Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device |
title_full_unstemmed |
Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device |
title_sort |
evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device |
publisher |
Society of TURAZ AKADEMI |
series |
Medicine Science |
issn |
2147-0634 |
publishDate |
2017-03-01 |
description |
The aim of the current study was to assess efficacy and safety of ab interno trabeculectomy surgery applied with trabectome device in early period. The study was designed among the 30 eyes of 26 patients who had undergone trabectome surgery with the diagnosis of open-angle glaucoma. Patients were evaluated as retrospectively in terms of preoperative and postoperative intraocular pressure (IOP), number of drugs used and complications. While the preoperative mean IOP was 28.78±5.57 mmHg (n:30) with the mean number of medications 3.40±1.04, the mean IOP was 18.24±5.54 mmHg (n:30) with the mean number of medications 0.90±1.27 at 1st month. At 3rd month the mean IOP was 16.37±3.36 mmHg (n:28) with the mean number of medications 0.70±1.10 and at 6th month the mean IOP was 16.51±3.80 mmHg (n:28) with the mean number of medications 1.13±0.96. When postoperative measurements compared with preoperative values, detected reductions in IOP and number of medications were statistically significant (P [Med-Science 2017; 6(1.000): 11-6] |
topic |
Trabectome surgery open angle glaucoma minimally invasive glaucoma surgery |
url |
http://www.ejmanager.com/fulltextpdf.php?mno=232252 |
work_keys_str_mv |
AT eyupduzgun evaluationoftheearlyresultsofabinternotrabeculectomysurgeryapplliedwithtrabectomedevice AT yildirayyildirim evaluationoftheearlyresultsofabinternotrabeculectomysurgeryapplliedwithtrabectomedevice AT akincakir evaluationoftheearlyresultsofabinternotrabeculectomysurgeryapplliedwithtrabectomedevice AT melihhamdiunal evaluationoftheearlyresultsofabinternotrabeculectomysurgeryapplliedwithtrabectomedevice AT aliayata evaluationoftheearlyresultsofabinternotrabeculectomysurgeryapplliedwithtrabectomedevice AT muratsonmez evaluationoftheearlyresultsofabinternotrabeculectomysurgeryapplliedwithtrabectomedevice |
_version_ |
1725996056871698432 |