Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device

The aim of the current study was to assess efficacy and safety of ab interno trabeculectomy surgery applied with trabectome device in early period. The study was designed among the 30 eyes of 26 patients who had undergone trabectome surgery with the diagnosis of open-angle glaucoma. Patients were ev...

Full description

Bibliographic Details
Main Authors: Eyup Duzgun, Yildiray Yildirim, Akin Cakir, Melih Hamdi Unal, Ali Ayata, Murat Sonmez
Format: Article
Language:English
Published: Society of TURAZ AKADEMI 2017-03-01
Series:Medicine Science
Subjects:
Online Access:http://www.ejmanager.com/fulltextpdf.php?mno=232252
id doaj-329225b65a694df384002105706e89e7
record_format Article
spelling doaj-329225b65a694df384002105706e89e72020-11-24T21:22:23ZengSociety of TURAZ AKADEMI Medicine Science2147-06342017-03-016111610.5455/medscience.2016.05.8501232252Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome deviceEyup Duzgun0Yildiray Yildirim1Akin Cakir2Melih Hamdi Unal3Ali Ayata4Murat Sonmez5Gumussuyu Military Hospital, Department of Ophthalmology, Beyoglu, Istanbul, Turkey. Gulhane Military Medical Academy Haydarpasa Training Hospital, Department of Ophthalmology, Istanbul, Turkey. Kasimpasa Military Hospital, Department of Ophthalmology, Beyoglu, Istanbul, Turkey Gulhane Military Medical Academy Haydarpasa Training Hospital, Department of Ophthalmology, Istanbul, Turkey. Gulhane Military Medical Academy Haydarpasa Training Hospital, Department of Ophthalmology, Istanbul, Turkey. Gulhane Military Medical Academy Haydarpasa Training Hospital, Department of Ophthalmology, Istanbul, Turkey.The aim of the current study was to assess efficacy and safety of ab interno trabeculectomy surgery applied with trabectome device in early period. The study was designed among the 30 eyes of 26 patients who had undergone trabectome surgery with the diagnosis of open-angle glaucoma. Patients were evaluated as retrospectively in terms of preoperative and postoperative intraocular pressure (IOP), number of drugs used and complications. While the preoperative mean IOP was 28.78±5.57 mmHg (n:30) with the mean number of medications 3.40±1.04, the mean IOP was 18.24±5.54 mmHg (n:30) with the mean number of medications 0.90±1.27 at 1st month. At 3rd month the mean IOP was 16.37±3.36 mmHg (n:28) with the mean number of medications 0.70±1.10 and at 6th month the mean IOP was 16.51±3.80 mmHg (n:28) with the mean number of medications 1.13±0.96. When postoperative measurements compared with preoperative values, detected reductions in IOP and number of medications were statistically significant (P [Med-Science 2017; 6(1.000): 11-6]http://www.ejmanager.com/fulltextpdf.php?mno=232252Trabectome surgeryopen angle glaucomaminimally invasive glaucoma surgery
collection DOAJ
language English
format Article
sources DOAJ
author Eyup Duzgun
Yildiray Yildirim
Akin Cakir
Melih Hamdi Unal
Ali Ayata
Murat Sonmez
spellingShingle Eyup Duzgun
Yildiray Yildirim
Akin Cakir
Melih Hamdi Unal
Ali Ayata
Murat Sonmez
Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device
Medicine Science
Trabectome surgery
open angle glaucoma
minimally invasive glaucoma surgery
author_facet Eyup Duzgun
Yildiray Yildirim
Akin Cakir
Melih Hamdi Unal
Ali Ayata
Murat Sonmez
author_sort Eyup Duzgun
title Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device
title_short Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device
title_full Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device
title_fullStr Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device
title_full_unstemmed Evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device
title_sort evaluation of the early results of ab interno trabeculectomy surgery appllied with trabectome device
publisher Society of TURAZ AKADEMI
series Medicine Science
issn 2147-0634
publishDate 2017-03-01
description The aim of the current study was to assess efficacy and safety of ab interno trabeculectomy surgery applied with trabectome device in early period. The study was designed among the 30 eyes of 26 patients who had undergone trabectome surgery with the diagnosis of open-angle glaucoma. Patients were evaluated as retrospectively in terms of preoperative and postoperative intraocular pressure (IOP), number of drugs used and complications. While the preoperative mean IOP was 28.78±5.57 mmHg (n:30) with the mean number of medications 3.40±1.04, the mean IOP was 18.24±5.54 mmHg (n:30) with the mean number of medications 0.90±1.27 at 1st month. At 3rd month the mean IOP was 16.37±3.36 mmHg (n:28) with the mean number of medications 0.70±1.10 and at 6th month the mean IOP was 16.51±3.80 mmHg (n:28) with the mean number of medications 1.13±0.96. When postoperative measurements compared with preoperative values, detected reductions in IOP and number of medications were statistically significant (P [Med-Science 2017; 6(1.000): 11-6]
topic Trabectome surgery
open angle glaucoma
minimally invasive glaucoma surgery
url http://www.ejmanager.com/fulltextpdf.php?mno=232252
work_keys_str_mv AT eyupduzgun evaluationoftheearlyresultsofabinternotrabeculectomysurgeryapplliedwithtrabectomedevice
AT yildirayyildirim evaluationoftheearlyresultsofabinternotrabeculectomysurgeryapplliedwithtrabectomedevice
AT akincakir evaluationoftheearlyresultsofabinternotrabeculectomysurgeryapplliedwithtrabectomedevice
AT melihhamdiunal evaluationoftheearlyresultsofabinternotrabeculectomysurgeryapplliedwithtrabectomedevice
AT aliayata evaluationoftheearlyresultsofabinternotrabeculectomysurgeryapplliedwithtrabectomedevice
AT muratsonmez evaluationoftheearlyresultsofabinternotrabeculectomysurgeryapplliedwithtrabectomedevice
_version_ 1725996056871698432