THE SAMPLING ERROR OF ROTATOR ESTIMATES OF EYE VOLUME

The vertical rotator is a design based stereological method for estimating object volume using measurements made on co-axial sections. Recently we used the method to estimate eye volume in a number of pathological studies. In the present note we apply an error prediction method for the vertical rota...

Full description

Bibliographic Details
Main Authors: Matthew G Reed, CV Howard
Format: Article
Language:English
Published: Slovenian Society for Stereology and Quantitative Image Analysis 2011-05-01
Series:Image Analysis and Stereology
Subjects:
Online Access:http://www.ias-iss.org/ojs/IAS/article/view/733
id doaj-332e6fa09e7641f29f7c2541c4864333
record_format Article
spelling doaj-332e6fa09e7641f29f7c2541c48643332020-11-24T22:25:19ZengSlovenian Society for Stereology and Quantitative Image AnalysisImage Analysis and Stereology1580-31391854-51652011-05-01221576110.5566/ias.v22.p57-61705THE SAMPLING ERROR OF ROTATOR ESTIMATES OF EYE VOLUMEMatthew G ReedCV HowardThe vertical rotator is a design based stereological method for estimating object volume using measurements made on co-axial sections. Recently we used the method to estimate eye volume in a number of pathological studies. In the present note we apply an error prediction method for the vertical rotator which has recently been published and analyse the raw data from our earlier study on eye volume in juvenile Dover sole. Application of the new theory allows us to assess the variance contributions due to rotating plane and test line sampling and estimate the underlying biological variability in eye volume. In all cases the coefficient of error introduced by the rotating test was about 10 times greater than due to the test line contribution.http://www.ias-iss.org/ojs/IAS/article/view/733rotatorstereologyvolume
collection DOAJ
language English
format Article
sources DOAJ
author Matthew G Reed
CV Howard
spellingShingle Matthew G Reed
CV Howard
THE SAMPLING ERROR OF ROTATOR ESTIMATES OF EYE VOLUME
Image Analysis and Stereology
rotator
stereology
volume
author_facet Matthew G Reed
CV Howard
author_sort Matthew G Reed
title THE SAMPLING ERROR OF ROTATOR ESTIMATES OF EYE VOLUME
title_short THE SAMPLING ERROR OF ROTATOR ESTIMATES OF EYE VOLUME
title_full THE SAMPLING ERROR OF ROTATOR ESTIMATES OF EYE VOLUME
title_fullStr THE SAMPLING ERROR OF ROTATOR ESTIMATES OF EYE VOLUME
title_full_unstemmed THE SAMPLING ERROR OF ROTATOR ESTIMATES OF EYE VOLUME
title_sort sampling error of rotator estimates of eye volume
publisher Slovenian Society for Stereology and Quantitative Image Analysis
series Image Analysis and Stereology
issn 1580-3139
1854-5165
publishDate 2011-05-01
description The vertical rotator is a design based stereological method for estimating object volume using measurements made on co-axial sections. Recently we used the method to estimate eye volume in a number of pathological studies. In the present note we apply an error prediction method for the vertical rotator which has recently been published and analyse the raw data from our earlier study on eye volume in juvenile Dover sole. Application of the new theory allows us to assess the variance contributions due to rotating plane and test line sampling and estimate the underlying biological variability in eye volume. In all cases the coefficient of error introduced by the rotating test was about 10 times greater than due to the test line contribution.
topic rotator
stereology
volume
url http://www.ias-iss.org/ojs/IAS/article/view/733
work_keys_str_mv AT matthewgreed thesamplingerrorofrotatorestimatesofeyevolume
AT cvhoward thesamplingerrorofrotatorestimatesofeyevolume
AT matthewgreed samplingerrorofrotatorestimatesofeyevolume
AT cvhoward samplingerrorofrotatorestimatesofeyevolume
_version_ 1725758314810179584