In vitro Evaluation of Dry Powder Inhaler Devices of Corticosteroid Preparations

Background: Although investigations of the drug aerosols generated from inhaled corticosteroid (ICS) preparations and combined drug preparations provide basic information about inhalation therapy, many clinicians have one-sided data about the precision of drug aerosols from the manufacturer. The pre...

Full description

Bibliographic Details
Main Authors: Gen Tamura, Hirokazu Sakae, Satoshi Fujino
Format: Article
Language:English
Published: Elsevier 2012-01-01
Series:Allergology International
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1323893015302057
id doaj-333a10ec9ad84cf5be8a4d2ab7f23c10
record_format Article
spelling doaj-333a10ec9ad84cf5be8a4d2ab7f23c102020-11-24T22:09:16ZengElsevierAllergology International1323-89302012-01-0161114915410.2332/allergolint.11-OA-0332In vitro Evaluation of Dry Powder Inhaler Devices of Corticosteroid PreparationsGen Tamura0Hirokazu Sakae1Satoshi Fujino2Airway Institute in Sendai Co., Ltd., MiyagiTokyo Dylec Corporation, Tokyo, Japan.Tokyo Dylec Corporation, Tokyo, Japan.Background: Although investigations of the drug aerosols generated from inhaled corticosteroid (ICS) preparations and combined drug preparations provide basic information about inhalation therapy, many clinicians have one-sided data about the precision of drug aerosols from the manufacturer. The present study was conducted to analyze and compare the performances of dry powder inhaler (DPI) devices of ICS and combined drug preparations. Methods: The particle size of individual aerosols was measured according to the time-of-flight principle in terms of their aerodynamic diameter by using the aerodynamic particle sizer spectrometer Model 3321. Percent aerosolization was measured using only stage #0 and backup filters of the Andersen non-viable sampler model AN-200. Results: The particle size distribution of aerosols generated from a Turbuhaler™ and Twisthaler™ showed a mono-modal distribution of less than 5 ^m. In contrast, Diskus™ showed a polydisperse distribution, ranging from 0.5 to 20 ^m. The percentages of DPI preparations converted into aerosols with a particle size less than 11 ^m at a suction flow rate of 28.3 L/min were 5.7-6.2% for Diskus, 37.5-47.0% for Turbuhaler, and 19.8% for Twisthaler. At a suction flow rate of 60 L/min, the conversion percentages for DPI preparations into aerosols with a particle size less than 7.6 ^m were 5.9-7.5%, 78.2-86.7%, and 43.5%, respectively. Conclusions: Because in vitro differences in the aerosolization among different DPI devices containing ICS and combined drug preparations were observed, prescribers of these preparations should consider whether the patients will benefit more from the treatment of the central airways versus the peripheral airways.http://www.sciencedirect.com/science/article/pii/S1323893015302057aerosolizationdevicesdry powder inhaler (DPI)inhaled corticosteroid (ICS)particle size
collection DOAJ
language English
format Article
sources DOAJ
author Gen Tamura
Hirokazu Sakae
Satoshi Fujino
spellingShingle Gen Tamura
Hirokazu Sakae
Satoshi Fujino
In vitro Evaluation of Dry Powder Inhaler Devices of Corticosteroid Preparations
Allergology International
aerosolization
devices
dry powder inhaler (DPI)
inhaled corticosteroid (ICS)
particle size
author_facet Gen Tamura
Hirokazu Sakae
Satoshi Fujino
author_sort Gen Tamura
title In vitro Evaluation of Dry Powder Inhaler Devices of Corticosteroid Preparations
title_short In vitro Evaluation of Dry Powder Inhaler Devices of Corticosteroid Preparations
title_full In vitro Evaluation of Dry Powder Inhaler Devices of Corticosteroid Preparations
title_fullStr In vitro Evaluation of Dry Powder Inhaler Devices of Corticosteroid Preparations
title_full_unstemmed In vitro Evaluation of Dry Powder Inhaler Devices of Corticosteroid Preparations
title_sort in vitro evaluation of dry powder inhaler devices of corticosteroid preparations
publisher Elsevier
series Allergology International
issn 1323-8930
publishDate 2012-01-01
description Background: Although investigations of the drug aerosols generated from inhaled corticosteroid (ICS) preparations and combined drug preparations provide basic information about inhalation therapy, many clinicians have one-sided data about the precision of drug aerosols from the manufacturer. The present study was conducted to analyze and compare the performances of dry powder inhaler (DPI) devices of ICS and combined drug preparations. Methods: The particle size of individual aerosols was measured according to the time-of-flight principle in terms of their aerodynamic diameter by using the aerodynamic particle sizer spectrometer Model 3321. Percent aerosolization was measured using only stage #0 and backup filters of the Andersen non-viable sampler model AN-200. Results: The particle size distribution of aerosols generated from a Turbuhaler™ and Twisthaler™ showed a mono-modal distribution of less than 5 ^m. In contrast, Diskus™ showed a polydisperse distribution, ranging from 0.5 to 20 ^m. The percentages of DPI preparations converted into aerosols with a particle size less than 11 ^m at a suction flow rate of 28.3 L/min were 5.7-6.2% for Diskus, 37.5-47.0% for Turbuhaler, and 19.8% for Twisthaler. At a suction flow rate of 60 L/min, the conversion percentages for DPI preparations into aerosols with a particle size less than 7.6 ^m were 5.9-7.5%, 78.2-86.7%, and 43.5%, respectively. Conclusions: Because in vitro differences in the aerosolization among different DPI devices containing ICS and combined drug preparations were observed, prescribers of these preparations should consider whether the patients will benefit more from the treatment of the central airways versus the peripheral airways.
topic aerosolization
devices
dry powder inhaler (DPI)
inhaled corticosteroid (ICS)
particle size
url http://www.sciencedirect.com/science/article/pii/S1323893015302057
work_keys_str_mv AT gentamura invitroevaluationofdrypowderinhalerdevicesofcorticosteroidpreparations
AT hirokazusakae invitroevaluationofdrypowderinhalerdevicesofcorticosteroidpreparations
AT satoshifujino invitroevaluationofdrypowderinhalerdevicesofcorticosteroidpreparations
_version_ 1725812718657601536