Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation.

Use of rotary Nickel-Titanium (NiTi) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT) has made it possible to accurately eva...

Full description

Bibliographic Details
Main Authors: Kiamars Honardar, Hadi Assadian, Shahriar Shahab, Zahra Jafari, Ali Kazemi, Kiumars Nazarimoghaddam, Mohammad Javad Kharrazifard, Hossein Labbaf
Format: Article
Language:English
Published: Tehran University of Medical Sciences 2014-08-01
Series:Frontiers in Dentistry
Subjects:
Online Access:https://jdt.tums.ac.ir/index.php/jdt/article/view/418
id doaj-3357d26616f04af9b690cc080b327c1f
record_format Article
spelling doaj-3357d26616f04af9b690cc080b327c1f2020-11-25T02:11:37ZengTehran University of Medical SciencesFrontiers in Dentistry2676-296X2014-08-01114394Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation.Kiamars Honardar0Hadi Assadian1Shahriar Shahab2Zahra Jafari3Ali Kazemi4Kiumars Nazarimoghaddam5Mohammad Javad Kharrazifard6Hossein Labbaf7Assistant Professor, Department of Endodontics, School of Dentistry, Shahed University, Tehran, Iran.Assistant Professor, Department of Endodontics, School of Dentistry, Shahed University, Tehran, Iran.Assistant Professor, Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahed University, Tehran, Iran.Postgraduate Student, Department of Endodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.Associate Professor, Department of Endodontics, School of Dentistry, Shahed University, Tehran, Iran.Assistant Professor, Department of Endodontics, School of Dentistry, Shahed University, Tehran, Iran.Epidemiologist, Dental Research Center Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.Assistant Professor, Department of Endodontics, School of Dentistry, Shahed University, Tehran, Iran.Use of rotary Nickel-Titanium (NiTi) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT) has made it possible to accurately evaluate geometrical changes following canal preparation. This study was carried out to compare canal centering ability and transportation of Twisted File and BioRaCe rotary systems by means of cone-beam computed tomography.Thirty root canals from freshly extracted mandibular and maxillary teeth were selected. Teeth were mounted and scanned before and after preparation by CBCT at different apical levels. Specimens were divided into 2 groups of 15. In the first group Twisted File and in the second, BioRaCe was used for canal preparation. Canal transportation and centering ability after preparation were assessed by NNT Viewer and Photoshop CS4 software. Statistical analysis was performed using t-test and two-way ANOVA.All samples showed deviations from the original axes of the canals. No significant differences were detected between the two rotary NiTi instruments for canal centering ability in all sections. Regarding canal transportation however, a significant difference was seen in the BioRaCe group at 7.5mm from the apex.Under the conditions of this in vitro study, Twisted File and BioRaCe rotary NiTi files retained original canal geometry.https://jdt.tums.ac.ir/index.php/jdt/article/view/418CBCTCentering AbilityCone-Beam Computed Tomography Canal InstrumentationNi-Ti rotary systemsTransportation
collection DOAJ
language English
format Article
sources DOAJ
author Kiamars Honardar
Hadi Assadian
Shahriar Shahab
Zahra Jafari
Ali Kazemi
Kiumars Nazarimoghaddam
Mohammad Javad Kharrazifard
Hossein Labbaf
spellingShingle Kiamars Honardar
Hadi Assadian
Shahriar Shahab
Zahra Jafari
Ali Kazemi
Kiumars Nazarimoghaddam
Mohammad Javad Kharrazifard
Hossein Labbaf
Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation.
Frontiers in Dentistry
CBCT
Centering Ability
Cone-Beam Computed Tomography Canal Instrumentation
Ni-Ti rotary systems
Transportation
author_facet Kiamars Honardar
Hadi Assadian
Shahriar Shahab
Zahra Jafari
Ali Kazemi
Kiumars Nazarimoghaddam
Mohammad Javad Kharrazifard
Hossein Labbaf
author_sort Kiamars Honardar
title Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation.
title_short Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation.
title_full Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation.
title_fullStr Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation.
title_full_unstemmed Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation.
title_sort cone-beam computed tomographic assessment of canal centering ability and transportation after preparation with twisted file and bio race instrumentation.
publisher Tehran University of Medical Sciences
series Frontiers in Dentistry
issn 2676-296X
publishDate 2014-08-01
description Use of rotary Nickel-Titanium (NiTi) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT) has made it possible to accurately evaluate geometrical changes following canal preparation. This study was carried out to compare canal centering ability and transportation of Twisted File and BioRaCe rotary systems by means of cone-beam computed tomography.Thirty root canals from freshly extracted mandibular and maxillary teeth were selected. Teeth were mounted and scanned before and after preparation by CBCT at different apical levels. Specimens were divided into 2 groups of 15. In the first group Twisted File and in the second, BioRaCe was used for canal preparation. Canal transportation and centering ability after preparation were assessed by NNT Viewer and Photoshop CS4 software. Statistical analysis was performed using t-test and two-way ANOVA.All samples showed deviations from the original axes of the canals. No significant differences were detected between the two rotary NiTi instruments for canal centering ability in all sections. Regarding canal transportation however, a significant difference was seen in the BioRaCe group at 7.5mm from the apex.Under the conditions of this in vitro study, Twisted File and BioRaCe rotary NiTi files retained original canal geometry.
topic CBCT
Centering Ability
Cone-Beam Computed Tomography Canal Instrumentation
Ni-Ti rotary systems
Transportation
url https://jdt.tums.ac.ir/index.php/jdt/article/view/418
work_keys_str_mv AT kiamarshonardar conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT hadiassadian conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT shahriarshahab conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT zahrajafari conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT alikazemi conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT kiumarsnazarimoghaddam conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT mohammadjavadkharrazifard conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT hosseinlabbaf conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
_version_ 1724913688981274624