Left ventricular mechanical dyssynchrony in patients with impaired left ventricular function undergoing gated SPECT myocardial perfusion imaging

Introduction: Gated SPECT myocardial perfusion imaging (MPI) has been used to quantify mechanical dyssynchrony. Mechanical dyssynchrony appears to be related to response to cardiac resynchronization therapy. Objective: To evaluate the presence and predictors of mechanical dyssynchrony in patients wi...

Full description

Bibliographic Details
Main Authors: Maria João Vidigal Ferreira, Rodolfo Silva, Nuno Cabanelas, Maria João Cunha, Domingos Ramos, Anabela Albuquerque, Rogério Teixeira, Ana Paula Moreira, Gracinda Costa, João Lima, Luís Augusto Providência
Format: Article
Language:English
Published: Elsevier 2013-05-01
Series:Revista Portuguesa de Cardiologia (English Edition)
Online Access:http://www.sciencedirect.com/science/article/pii/S2174204913001244
id doaj-36bf78382efb4635883e2f8269fa3972
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Maria João Vidigal Ferreira
Rodolfo Silva
Nuno Cabanelas
Maria João Cunha
Domingos Ramos
Anabela Albuquerque
Rogério Teixeira
Ana Paula Moreira
Gracinda Costa
João Lima
Luís Augusto Providência
spellingShingle Maria João Vidigal Ferreira
Rodolfo Silva
Nuno Cabanelas
Maria João Cunha
Domingos Ramos
Anabela Albuquerque
Rogério Teixeira
Ana Paula Moreira
Gracinda Costa
João Lima
Luís Augusto Providência
Left ventricular mechanical dyssynchrony in patients with impaired left ventricular function undergoing gated SPECT myocardial perfusion imaging
Revista Portuguesa de Cardiologia (English Edition)
author_facet Maria João Vidigal Ferreira
Rodolfo Silva
Nuno Cabanelas
Maria João Cunha
Domingos Ramos
Anabela Albuquerque
Rogério Teixeira
Ana Paula Moreira
Gracinda Costa
João Lima
Luís Augusto Providência
author_sort Maria João Vidigal Ferreira
title Left ventricular mechanical dyssynchrony in patients with impaired left ventricular function undergoing gated SPECT myocardial perfusion imaging
title_short Left ventricular mechanical dyssynchrony in patients with impaired left ventricular function undergoing gated SPECT myocardial perfusion imaging
title_full Left ventricular mechanical dyssynchrony in patients with impaired left ventricular function undergoing gated SPECT myocardial perfusion imaging
title_fullStr Left ventricular mechanical dyssynchrony in patients with impaired left ventricular function undergoing gated SPECT myocardial perfusion imaging
title_full_unstemmed Left ventricular mechanical dyssynchrony in patients with impaired left ventricular function undergoing gated SPECT myocardial perfusion imaging
title_sort left ventricular mechanical dyssynchrony in patients with impaired left ventricular function undergoing gated spect myocardial perfusion imaging
publisher Elsevier
series Revista Portuguesa de Cardiologia (English Edition)
issn 2174-2049
publishDate 2013-05-01
description Introduction: Gated SPECT myocardial perfusion imaging (MPI) has been used to quantify mechanical dyssynchrony. Mechanical dyssynchrony appears to be related to response to cardiac resynchronization therapy. Objective: To evaluate the presence and predictors of mechanical dyssynchrony in patients with impaired left ventricular function (LVEF) ≤50%. Methods: The study included 143 consecutive patients referred for gated SPECT MPI with LVEF ≤50%. Gated SPECT MPI was performed according to a stress/rest protocol acquiring images with Tc 99m-tetrofosmin. Emory Cardiac Toolbox software was used for phase analysis and a standard deviation (SD) ≥43° was considered to indicate mechanical dyssynchrony. Results: Mechanical dyssynchrony was present in 53.1% of the patients. Its predictors were diabetes (OR 2.0, p≤0.05), summed stress score (OR 1.1, p≤0.0005), summed rest score (OR 1.1, p≤0.0001), end-diastolic volume (OR 1.0, p≤0.0001), LVEF (OR 0.9, p≤0.0001), LVEF ≤35% (OR 3.1, p≤0.005) and LVEF ≤35% and QRS ≥120 ms (OR 3.5, p≤0.05). In this study QRS width and QRS ≥120 ms were not predictors of mechanical dyssynchrony. Conclusions: Myocardial perfusion imaging can be used to assess mechanical dyssynchrony. In patients with impaired ventricular function mechanical dyssynchrony was highly prevalent and was related to parameters of left ventricular function and perfusion. Resumo: Introdução: A avaliação de dessincronia ventricular mecânica através da análise do histograma de fase na cintigrafia de perfusão miocárdica tem sido descrita na literatura. Segundo a evidência atual, a presença de dessincronia mecânica encontra-se relacionada com a resposta à terapêutica de ressincronização. Objectivos: Avaliar a presença e os preditores de dessincronia ventricular mecânica em pacientes com fração de ejeção ventricular esquerda (FEVE) ≤ 50%. Métodos: Foram incluídos pacientes que realizaram cintigrafia de perfusão miocárdica e cuja FEVE foi inferior ou igual a 50%. A amostra estudada incluiu 143 pacientes. As imagens de perfusão foram adquiridas de acordo com o protocolo esforço seguido de repouso com Tc-99m Tetrafosmina. A avaliação de dessincronia baseou-se na determinação do desvio padrão obtido através da análise do histograma de fase (Emory Toolbox Software). A presença de dessincronia foi considerada quando o desvio-padrão no histograma de fase foi superior ou igual a 43°. Resultados: A presença de dessincronia foi observada 53,1% dos doentes. Foram preditores de dessincronia, a diabetes (OR 2,0, p ≤ 0,05), o score de esforço (OR 1,1, p ≤ 0,0005), o score de repouso (OR 1,1, p ≤ 0,0001), o volume telediastólico (OR 1,0, p ≤ 0,0001), a FEVE (OR 0,9, p ≤ 0,0001), FEVE ≤ 35% (OR 3,1, p ≤ 0,005) e a presença em simultâneo de FEVE ≤ 35% e QRS ≥120 ms (OR 3,5, p ≤ 0,05). Nesta avaliação a duração do QRS ou a presença de QRS ≥ 120 ms não se relacionaram com a presença de dessincronia. Conclusões: A cintigrafia de perfusão miocárdica pode ser usada na avaliação de dessincronia e esta tem uma elevada prevalência em pacientes com FEVE diminuída relacionando-se com parâmetros de função ventricular e perfusão miocárdica. Keywords: Myocardial perfusion imaging, Gated SPECT, Dyssynchrony, Coronary artery disease, Heart failure, Palavras-chave: Cintigrafia de perfusão miocárdica, Gated SPECT, Dessincronia, Doença coronária, Insuficiência cardíaca
url http://www.sciencedirect.com/science/article/pii/S2174204913001244
work_keys_str_mv AT mariajoaovidigalferreira leftventricularmechanicaldyssynchronyinpatientswithimpairedleftventricularfunctionundergoinggatedspectmyocardialperfusionimaging
AT rodolfosilva leftventricularmechanicaldyssynchronyinpatientswithimpairedleftventricularfunctionundergoinggatedspectmyocardialperfusionimaging
AT nunocabanelas leftventricularmechanicaldyssynchronyinpatientswithimpairedleftventricularfunctionundergoinggatedspectmyocardialperfusionimaging
AT mariajoaocunha leftventricularmechanicaldyssynchronyinpatientswithimpairedleftventricularfunctionundergoinggatedspectmyocardialperfusionimaging
AT domingosramos leftventricularmechanicaldyssynchronyinpatientswithimpairedleftventricularfunctionundergoinggatedspectmyocardialperfusionimaging
AT anabelaalbuquerque leftventricularmechanicaldyssynchronyinpatientswithimpairedleftventricularfunctionundergoinggatedspectmyocardialperfusionimaging
AT rogerioteixeira leftventricularmechanicaldyssynchronyinpatientswithimpairedleftventricularfunctionundergoinggatedspectmyocardialperfusionimaging
AT anapaulamoreira leftventricularmechanicaldyssynchronyinpatientswithimpairedleftventricularfunctionundergoinggatedspectmyocardialperfusionimaging
AT gracindacosta leftventricularmechanicaldyssynchronyinpatientswithimpairedleftventricularfunctionundergoinggatedspectmyocardialperfusionimaging
AT joaolima leftventricularmechanicaldyssynchronyinpatientswithimpairedleftventricularfunctionundergoinggatedspectmyocardialperfusionimaging
AT luisaugustoprovidencia leftventricularmechanicaldyssynchronyinpatientswithimpairedleftventricularfunctionundergoinggatedspectmyocardialperfusionimaging
_version_ 1724783198296080384
spelling doaj-36bf78382efb4635883e2f8269fa39722020-11-25T02:40:04ZengElsevierRevista Portuguesa de Cardiologia (English Edition)2174-20492013-05-01325387394Left ventricular mechanical dyssynchrony in patients with impaired left ventricular function undergoing gated SPECT myocardial perfusion imagingMaria João Vidigal Ferreira0Rodolfo Silva1Nuno Cabanelas2Maria João Cunha3Domingos Ramos4Anabela Albuquerque5Rogério Teixeira6Ana Paula Moreira7Gracinda Costa8João Lima9Luís Augusto Providência10Faculdade de Medicina, Universidade de Coimbra, Centro Hospitalar e Universitário de Coimbra (HUC), Serviço de Cardiologia, Coimbra, Portugal; Corresponding author.Centro Hospitalar e Universitário de Coimbra (HUC), Serviço de Medicina Nuclear, Coimbra, PortugalCentro Hospitalar e Universitário de Coimbra (HUC), Serviço de Cardiologia, Coimbra, PortugalCentro Hospitalar e Universitário de Coimbra (HUC), Serviço de Medicina Nuclear, Coimbra, PortugalCentro Hospitalar e Universitário de Coimbra (HUC), Serviço de Cardiologia, Coimbra, PortugalCentro Hospitalar e Universitário de Coimbra (HUC), Serviço de Medicina Nuclear, Coimbra, PortugalCentro Hospitalar e Universitário de Coimbra (HUC), Serviço de Cardiologia, Coimbra, PortugalCentro Hospitalar e Universitário de Coimbra (HUC), Serviço de Medicina Nuclear, Coimbra, PortugalCentro Hospitalar e Universitário de Coimbra (HUC), Serviço de Medicina Nuclear, Coimbra, PortugalCentro Hospitalar e Universitário de Coimbra (HUC), Serviço de Medicina Nuclear, Coimbra, PortugalCentro Hospitalar e Universitário de Coimbra (HUC), Serviço de Cardiologia, Coimbra, PortugalIntroduction: Gated SPECT myocardial perfusion imaging (MPI) has been used to quantify mechanical dyssynchrony. Mechanical dyssynchrony appears to be related to response to cardiac resynchronization therapy. Objective: To evaluate the presence and predictors of mechanical dyssynchrony in patients with impaired left ventricular function (LVEF) ≤50%. Methods: The study included 143 consecutive patients referred for gated SPECT MPI with LVEF ≤50%. Gated SPECT MPI was performed according to a stress/rest protocol acquiring images with Tc 99m-tetrofosmin. Emory Cardiac Toolbox software was used for phase analysis and a standard deviation (SD) ≥43° was considered to indicate mechanical dyssynchrony. Results: Mechanical dyssynchrony was present in 53.1% of the patients. Its predictors were diabetes (OR 2.0, p≤0.05), summed stress score (OR 1.1, p≤0.0005), summed rest score (OR 1.1, p≤0.0001), end-diastolic volume (OR 1.0, p≤0.0001), LVEF (OR 0.9, p≤0.0001), LVEF ≤35% (OR 3.1, p≤0.005) and LVEF ≤35% and QRS ≥120 ms (OR 3.5, p≤0.05). In this study QRS width and QRS ≥120 ms were not predictors of mechanical dyssynchrony. Conclusions: Myocardial perfusion imaging can be used to assess mechanical dyssynchrony. In patients with impaired ventricular function mechanical dyssynchrony was highly prevalent and was related to parameters of left ventricular function and perfusion. Resumo: Introdução: A avaliação de dessincronia ventricular mecânica através da análise do histograma de fase na cintigrafia de perfusão miocárdica tem sido descrita na literatura. Segundo a evidência atual, a presença de dessincronia mecânica encontra-se relacionada com a resposta à terapêutica de ressincronização. Objectivos: Avaliar a presença e os preditores de dessincronia ventricular mecânica em pacientes com fração de ejeção ventricular esquerda (FEVE) ≤ 50%. Métodos: Foram incluídos pacientes que realizaram cintigrafia de perfusão miocárdica e cuja FEVE foi inferior ou igual a 50%. A amostra estudada incluiu 143 pacientes. As imagens de perfusão foram adquiridas de acordo com o protocolo esforço seguido de repouso com Tc-99m Tetrafosmina. A avaliação de dessincronia baseou-se na determinação do desvio padrão obtido através da análise do histograma de fase (Emory Toolbox Software). A presença de dessincronia foi considerada quando o desvio-padrão no histograma de fase foi superior ou igual a 43°. Resultados: A presença de dessincronia foi observada 53,1% dos doentes. Foram preditores de dessincronia, a diabetes (OR 2,0, p ≤ 0,05), o score de esforço (OR 1,1, p ≤ 0,0005), o score de repouso (OR 1,1, p ≤ 0,0001), o volume telediastólico (OR 1,0, p ≤ 0,0001), a FEVE (OR 0,9, p ≤ 0,0001), FEVE ≤ 35% (OR 3,1, p ≤ 0,005) e a presença em simultâneo de FEVE ≤ 35% e QRS ≥120 ms (OR 3,5, p ≤ 0,05). Nesta avaliação a duração do QRS ou a presença de QRS ≥ 120 ms não se relacionaram com a presença de dessincronia. Conclusões: A cintigrafia de perfusão miocárdica pode ser usada na avaliação de dessincronia e esta tem uma elevada prevalência em pacientes com FEVE diminuída relacionando-se com parâmetros de função ventricular e perfusão miocárdica. Keywords: Myocardial perfusion imaging, Gated SPECT, Dyssynchrony, Coronary artery disease, Heart failure, Palavras-chave: Cintigrafia de perfusão miocárdica, Gated SPECT, Dessincronia, Doença coronária, Insuficiência cardíacahttp://www.sciencedirect.com/science/article/pii/S2174204913001244