Design and Parameter Tuning of Nonlinear Active Disturbance Rejection Controller for Permanent Magnet Direct Drive Wind Power Converter System

When the permanent magnet direct-drive wind power converter system is disturbed by the grid side and the motor side, the output voltage of the converter and the DC bus voltage will change suddenly, and the power quality of the grid will deteriorate. The nonlinear active disturbance rejection control...

Full description

Bibliographic Details
Main Authors: Bin Zhang, Shijun You, Mao Liu, Xuesong Zhou
Format: Article
Language:English
Published: IEEE 2021-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/9335997/
id doaj-38026c54dc7a4df485b45db1f8ee79bd
record_format Article
spelling doaj-38026c54dc7a4df485b45db1f8ee79bd2021-03-30T14:59:39ZengIEEEIEEE Access2169-35362021-01-019338363384810.1109/ACCESS.2021.30546679335997Design and Parameter Tuning of Nonlinear Active Disturbance Rejection Controller for Permanent Magnet Direct Drive Wind Power Converter SystemBin Zhang0Shijun You1Mao Liu2https://orcid.org/0000-0003-0176-3459Xuesong Zhou3School of Environmental Science and Engineering, Tianjin University, Tianjin, ChinaSchool of Environmental Science and Engineering, Tianjin University, Tianjin, ChinaSchool of Electrical and Electronic Engineering, Tianjin University of Technology, Tianjin, ChinaSchool of Electrical and Electronic Engineering, Tianjin University of Technology, Tianjin, ChinaWhen the permanent magnet direct-drive wind power converter system is disturbed by the grid side and the motor side, the output voltage of the converter and the DC bus voltage will change suddenly, and the power quality of the grid will deteriorate. The nonlinear active disturbance rejection controller (NLADRC) is used in the grid-connected inverter control system. Because of its ability to estimate and compensate disturbances, it can effectively improve the system's anti-disturbance ability and tracking accuracy. However, NLADRC still has problems such as many parameters to be adjusted and unclear physical meaning. This article explores the influence of various parameters on the dynamic performance of the entire system, and summarizes the direction and law of parameter tuning. At the same time, the frequency domain analysis method is used to express the gain parameter in the expanded state observer in the form of bandwidth, which provides a basis for parameter adjustment in actual engineering. The control algorithm proposed in this article is applied to the 3MW permanent magnet direct-drive wind power experimental platform. The experimental results under various working conditions show that NLADRC can effectively improve the anti-interference performance of the grid-connected inverter.https://ieeexplore.ieee.org/document/9335997/Active disturbance rejection controlwind power generationgrid connected converterparameter tuning
collection DOAJ
language English
format Article
sources DOAJ
author Bin Zhang
Shijun You
Mao Liu
Xuesong Zhou
spellingShingle Bin Zhang
Shijun You
Mao Liu
Xuesong Zhou
Design and Parameter Tuning of Nonlinear Active Disturbance Rejection Controller for Permanent Magnet Direct Drive Wind Power Converter System
IEEE Access
Active disturbance rejection control
wind power generation
grid connected converter
parameter tuning
author_facet Bin Zhang
Shijun You
Mao Liu
Xuesong Zhou
author_sort Bin Zhang
title Design and Parameter Tuning of Nonlinear Active Disturbance Rejection Controller for Permanent Magnet Direct Drive Wind Power Converter System
title_short Design and Parameter Tuning of Nonlinear Active Disturbance Rejection Controller for Permanent Magnet Direct Drive Wind Power Converter System
title_full Design and Parameter Tuning of Nonlinear Active Disturbance Rejection Controller for Permanent Magnet Direct Drive Wind Power Converter System
title_fullStr Design and Parameter Tuning of Nonlinear Active Disturbance Rejection Controller for Permanent Magnet Direct Drive Wind Power Converter System
title_full_unstemmed Design and Parameter Tuning of Nonlinear Active Disturbance Rejection Controller for Permanent Magnet Direct Drive Wind Power Converter System
title_sort design and parameter tuning of nonlinear active disturbance rejection controller for permanent magnet direct drive wind power converter system
publisher IEEE
series IEEE Access
issn 2169-3536
publishDate 2021-01-01
description When the permanent magnet direct-drive wind power converter system is disturbed by the grid side and the motor side, the output voltage of the converter and the DC bus voltage will change suddenly, and the power quality of the grid will deteriorate. The nonlinear active disturbance rejection controller (NLADRC) is used in the grid-connected inverter control system. Because of its ability to estimate and compensate disturbances, it can effectively improve the system's anti-disturbance ability and tracking accuracy. However, NLADRC still has problems such as many parameters to be adjusted and unclear physical meaning. This article explores the influence of various parameters on the dynamic performance of the entire system, and summarizes the direction and law of parameter tuning. At the same time, the frequency domain analysis method is used to express the gain parameter in the expanded state observer in the form of bandwidth, which provides a basis for parameter adjustment in actual engineering. The control algorithm proposed in this article is applied to the 3MW permanent magnet direct-drive wind power experimental platform. The experimental results under various working conditions show that NLADRC can effectively improve the anti-interference performance of the grid-connected inverter.
topic Active disturbance rejection control
wind power generation
grid connected converter
parameter tuning
url https://ieeexplore.ieee.org/document/9335997/
work_keys_str_mv AT binzhang designandparametertuningofnonlinearactivedisturbancerejectioncontrollerforpermanentmagnetdirectdrivewindpowerconvertersystem
AT shijunyou designandparametertuningofnonlinearactivedisturbancerejectioncontrollerforpermanentmagnetdirectdrivewindpowerconvertersystem
AT maoliu designandparametertuningofnonlinearactivedisturbancerejectioncontrollerforpermanentmagnetdirectdrivewindpowerconvertersystem
AT xuesongzhou designandparametertuningofnonlinearactivedisturbancerejectioncontrollerforpermanentmagnetdirectdrivewindpowerconvertersystem
_version_ 1724180198623019008