Pre-pressure influences on the traveling wave ultrasonic motor performance: A theoretical analysis with experimental verification

In order to improve the output performance of the rotating traveling wave ultrasonic motor and study the optimal pre-pressures under different loads, the theoretical calculation and experimental verification on a TRUM-70H ultrasonic motor were carried out. The dynamic model of an ultrasonic motor is...

Full description

Bibliographic Details
Main Authors: Hongxing Wang, Zhengyang Pan, Hua Zhu, Yong Guo
Format: Article
Language:English
Published: AIP Publishing LLC 2020-11-01
Series:AIP Advances
Online Access:http://dx.doi.org/10.1063/5.0028282
id doaj-38ca645f7fab491f8f9ef74638db57b1
record_format Article
spelling doaj-38ca645f7fab491f8f9ef74638db57b12020-12-04T12:45:21ZengAIP Publishing LLCAIP Advances2158-32262020-11-011011115211115211-810.1063/5.0028282Pre-pressure influences on the traveling wave ultrasonic motor performance: A theoretical analysis with experimental verificationHongxing Wang0Zhengyang Pan1Hua Zhu2Yong Guo3State Key Laboratory of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, ChinaState Key Laboratory of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, ChinaState Key Laboratory of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, ChinaState Key Laboratory of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, ChinaIn order to improve the output performance of the rotating traveling wave ultrasonic motor and study the optimal pre-pressures under different loads, the theoretical calculation and experimental verification on a TRUM-70H ultrasonic motor were carried out. The dynamic model of an ultrasonic motor is established, and the influence of pre-pressure on the mechanical properties of the ultrasonic motor is analyzed. Taking the TRUM-70H ultrasonic motor as the object of study, the relationship between the optimum pre-pressure and the load torque is analyzed. A multi-functional testing platform for an ultrasonic motor is built to verify the theoretical derivation results, and the reason for the error is also pointed out. According to the conclusion, the pre-pressure should be selected according to the load when the ultrasonic motors are assembled. The results show that there is a coupling relationship between the pre-pressure and the load torque on the speed of the ultrasonic motor. In the effective working range of the ultrasonic motor, the optimum pre-pressure is approximately linearly positively correlated with the load torque. When the pre-pressure is set according to the actual load demand during assembly, the output efficiency of the ultrasonic motor can be improved.http://dx.doi.org/10.1063/5.0028282
collection DOAJ
language English
format Article
sources DOAJ
author Hongxing Wang
Zhengyang Pan
Hua Zhu
Yong Guo
spellingShingle Hongxing Wang
Zhengyang Pan
Hua Zhu
Yong Guo
Pre-pressure influences on the traveling wave ultrasonic motor performance: A theoretical analysis with experimental verification
AIP Advances
author_facet Hongxing Wang
Zhengyang Pan
Hua Zhu
Yong Guo
author_sort Hongxing Wang
title Pre-pressure influences on the traveling wave ultrasonic motor performance: A theoretical analysis with experimental verification
title_short Pre-pressure influences on the traveling wave ultrasonic motor performance: A theoretical analysis with experimental verification
title_full Pre-pressure influences on the traveling wave ultrasonic motor performance: A theoretical analysis with experimental verification
title_fullStr Pre-pressure influences on the traveling wave ultrasonic motor performance: A theoretical analysis with experimental verification
title_full_unstemmed Pre-pressure influences on the traveling wave ultrasonic motor performance: A theoretical analysis with experimental verification
title_sort pre-pressure influences on the traveling wave ultrasonic motor performance: a theoretical analysis with experimental verification
publisher AIP Publishing LLC
series AIP Advances
issn 2158-3226
publishDate 2020-11-01
description In order to improve the output performance of the rotating traveling wave ultrasonic motor and study the optimal pre-pressures under different loads, the theoretical calculation and experimental verification on a TRUM-70H ultrasonic motor were carried out. The dynamic model of an ultrasonic motor is established, and the influence of pre-pressure on the mechanical properties of the ultrasonic motor is analyzed. Taking the TRUM-70H ultrasonic motor as the object of study, the relationship between the optimum pre-pressure and the load torque is analyzed. A multi-functional testing platform for an ultrasonic motor is built to verify the theoretical derivation results, and the reason for the error is also pointed out. According to the conclusion, the pre-pressure should be selected according to the load when the ultrasonic motors are assembled. The results show that there is a coupling relationship between the pre-pressure and the load torque on the speed of the ultrasonic motor. In the effective working range of the ultrasonic motor, the optimum pre-pressure is approximately linearly positively correlated with the load torque. When the pre-pressure is set according to the actual load demand during assembly, the output efficiency of the ultrasonic motor can be improved.
url http://dx.doi.org/10.1063/5.0028282
work_keys_str_mv AT hongxingwang prepressureinfluencesonthetravelingwaveultrasonicmotorperformanceatheoreticalanalysiswithexperimentalverification
AT zhengyangpan prepressureinfluencesonthetravelingwaveultrasonicmotorperformanceatheoreticalanalysiswithexperimentalverification
AT huazhu prepressureinfluencesonthetravelingwaveultrasonicmotorperformanceatheoreticalanalysiswithexperimentalverification
AT yongguo prepressureinfluencesonthetravelingwaveultrasonicmotorperformanceatheoreticalanalysiswithexperimentalverification
_version_ 1724400433833705472