Diagnostic accuracy of ultrasonography compared to unenhanced CT for stone and obstruction in patients with renal failure

<p>Abstract</p> <p>Background</p> <p>To determine accuracy of ultrasound (US) kidney, ureter and bladder (KUB) compared to un-enhanced helical CT (UHCT) in patients with renal failure in the diagnosis of stone and obstruction.</p> <p>Methods</p> <p&...

Full description

Bibliographic Details
Main Authors: Jafri Aftab H, Ather M Hammad, Sulaiman M Nasir
Format: Article
Language:English
Published: BMC 2004-07-01
Series:BMC Medical Imaging
Online Access:http://www.biomedcentral.com/1471-2342/4/2
id doaj-39dc694501dc4d6aa0c9d0989439e00a
record_format Article
spelling doaj-39dc694501dc4d6aa0c9d0989439e00a2020-11-25T02:51:55ZengBMCBMC Medical Imaging1471-23422004-07-0141210.1186/1471-2342-4-2Diagnostic accuracy of ultrasonography compared to unenhanced CT for stone and obstruction in patients with renal failureJafri Aftab HAther M HammadSulaiman M Nasir<p>Abstract</p> <p>Background</p> <p>To determine accuracy of ultrasound (US) kidney, ureter and bladder (KUB) compared to un-enhanced helical CT (UHCT) in patients with renal failure in the diagnosis of stone and obstruction.</p> <p>Methods</p> <p>This is a case controlled study conducted in the period from June 2000 to July 2003 at a university hospital. All patients had both US and UHCT scan. Patients with serum creatinine ≥ 1.8 mg/dl were included in the study. Only direct visualization of stone was considered as confirmatory. In both the studies, UHCT and US, presence of stone and obstruction were noted. The relevant biochemicals, radiological and clinical records of all the patients were analyzed. Data was analyzed using commercially available software.</p> <p>Results</p> <p>During the period of study 864 patients had UHCT for evaluation of the urinary tract in patients presenting with flank pain. Out of these 34 patients had both UHCT and US done within a span of one day and had serum creatinine of ≥1.8 mg/dl. Mean age was 48 ±15.8 years and 59% of patients were males. UHCT identified renal stones in 21 (62%), whereas 17 of these were identified on US, with a sensitivity of 81%. Of the four patients with renal stones missed on US, three were identified on plain x-ray; the mean size of stones missed was 6.3 mm. Of the 22 (65%) patients with ureteric stone on UHCT, US could only identify 10; a further 7 were identified on x-ray KUB, giving a sensitivity of 45% (US alone) and 77% (US with x-ray KUB).</p> <p>Conclusions</p> <p>US is sensitive and specific for renal stones, 81% and 100% and for hydronephrosis, 93% and 100%, respectively. Its sensitivity to pick ureteric stone (46%) and to identify hydroureter (50%) is low. Addition of x-ray KUB abdomen increases the sensitivity for ureteric stones to 77%.</p> http://www.biomedcentral.com/1471-2342/4/2
collection DOAJ
language English
format Article
sources DOAJ
author Jafri Aftab H
Ather M Hammad
Sulaiman M Nasir
spellingShingle Jafri Aftab H
Ather M Hammad
Sulaiman M Nasir
Diagnostic accuracy of ultrasonography compared to unenhanced CT for stone and obstruction in patients with renal failure
BMC Medical Imaging
author_facet Jafri Aftab H
Ather M Hammad
Sulaiman M Nasir
author_sort Jafri Aftab H
title Diagnostic accuracy of ultrasonography compared to unenhanced CT for stone and obstruction in patients with renal failure
title_short Diagnostic accuracy of ultrasonography compared to unenhanced CT for stone and obstruction in patients with renal failure
title_full Diagnostic accuracy of ultrasonography compared to unenhanced CT for stone and obstruction in patients with renal failure
title_fullStr Diagnostic accuracy of ultrasonography compared to unenhanced CT for stone and obstruction in patients with renal failure
title_full_unstemmed Diagnostic accuracy of ultrasonography compared to unenhanced CT for stone and obstruction in patients with renal failure
title_sort diagnostic accuracy of ultrasonography compared to unenhanced ct for stone and obstruction in patients with renal failure
publisher BMC
series BMC Medical Imaging
issn 1471-2342
publishDate 2004-07-01
description <p>Abstract</p> <p>Background</p> <p>To determine accuracy of ultrasound (US) kidney, ureter and bladder (KUB) compared to un-enhanced helical CT (UHCT) in patients with renal failure in the diagnosis of stone and obstruction.</p> <p>Methods</p> <p>This is a case controlled study conducted in the period from June 2000 to July 2003 at a university hospital. All patients had both US and UHCT scan. Patients with serum creatinine ≥ 1.8 mg/dl were included in the study. Only direct visualization of stone was considered as confirmatory. In both the studies, UHCT and US, presence of stone and obstruction were noted. The relevant biochemicals, radiological and clinical records of all the patients were analyzed. Data was analyzed using commercially available software.</p> <p>Results</p> <p>During the period of study 864 patients had UHCT for evaluation of the urinary tract in patients presenting with flank pain. Out of these 34 patients had both UHCT and US done within a span of one day and had serum creatinine of ≥1.8 mg/dl. Mean age was 48 ±15.8 years and 59% of patients were males. UHCT identified renal stones in 21 (62%), whereas 17 of these were identified on US, with a sensitivity of 81%. Of the four patients with renal stones missed on US, three were identified on plain x-ray; the mean size of stones missed was 6.3 mm. Of the 22 (65%) patients with ureteric stone on UHCT, US could only identify 10; a further 7 were identified on x-ray KUB, giving a sensitivity of 45% (US alone) and 77% (US with x-ray KUB).</p> <p>Conclusions</p> <p>US is sensitive and specific for renal stones, 81% and 100% and for hydronephrosis, 93% and 100%, respectively. Its sensitivity to pick ureteric stone (46%) and to identify hydroureter (50%) is low. Addition of x-ray KUB abdomen increases the sensitivity for ureteric stones to 77%.</p>
url http://www.biomedcentral.com/1471-2342/4/2
work_keys_str_mv AT jafriaftabh diagnosticaccuracyofultrasonographycomparedtounenhancedctforstoneandobstructioninpatientswithrenalfailure
AT athermhammad diagnosticaccuracyofultrasonographycomparedtounenhancedctforstoneandobstructioninpatientswithrenalfailure
AT sulaimanmnasir diagnosticaccuracyofultrasonographycomparedtounenhancedctforstoneandobstructioninpatientswithrenalfailure
_version_ 1724732643708239872