Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients

AIM: To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. METHODS: Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top,...

Full description

Bibliographic Details
Main Authors: Sha-Sha Yu, Hui Song, Xin Tang
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2017-11-01
Series:International Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.cn/en_publish/2017/11/20171111.pdf
id doaj-3a2ca62b8a7b4727a30ba8c69b8e7b5e
record_format Article
spelling doaj-3a2ca62b8a7b4727a30ba8c69b8e7b5e2020-11-24T23:47:29ZengPress of International Journal of Ophthalmology (IJO PRESS)International Journal of Ophthalmology2222-39592227-48982017-11-0110111703170910.18240/ijo.2017.11.11Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patientsSha-Sha Yu0Hui Song1Xin Tang2Clinical College of Ophthalmology, Tianjin Medical University, Tianjin 300020, ChinaTianjin Eye Hospital, Tianjin 300020, ChinaClinical College of Ophthalmology, Tianjin Medical University, Tianjin 300020, China; Tianjin Eye Hospital, Tianjin 300020, China; Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin 300020, China; Tianjin Eye Institute, Tianjin 300020, ChinaAIM: To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. METHODS: Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability. RESULTS: Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. CONCLUSION: Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically.http://www.ijo.cn/en_publish/2017/11/20171111.pdf1709"Ophtha Top topographycorneal parametersrepeatabilitycomparability "
collection DOAJ
language English
format Article
sources DOAJ
author Sha-Sha Yu
Hui Song
Xin Tang
spellingShingle Sha-Sha Yu
Hui Song
Xin Tang
Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients
International Journal of Ophthalmology
1709
"Ophtha Top topography
corneal parameters
repeatability
comparability "
author_facet Sha-Sha Yu
Hui Song
Xin Tang
author_sort Sha-Sha Yu
title Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients
title_short Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients
title_full Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients
title_fullStr Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients
title_full_unstemmed Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients
title_sort repeatability of ophtha top topography and comparison with iol-master and lenstarls900 in cataract patients
publisher Press of International Journal of Ophthalmology (IJO PRESS)
series International Journal of Ophthalmology
issn 2222-3959
2227-4898
publishDate 2017-11-01
description AIM: To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. METHODS: Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability. RESULTS: Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. CONCLUSION: Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically.
topic 1709
"Ophtha Top topography
corneal parameters
repeatability
comparability "
url http://www.ijo.cn/en_publish/2017/11/20171111.pdf
work_keys_str_mv AT shashayu repeatabilityofophthatoptopographyandcomparisonwithiolmasterandlenstarls900incataractpatients
AT huisong repeatabilityofophthatoptopographyandcomparisonwithiolmasterandlenstarls900incataractpatients
AT xintang repeatabilityofophthatoptopographyandcomparisonwithiolmasterandlenstarls900incataractpatients
_version_ 1725489429391343616