Simultaneous Determination of Lactulose and Lactose in Conserved Milk by HPLC-RID

Heat treatment is applied to dairy products to ensure microbiological quality and increase the shelf life. However, a suitable control of this process is necessary to guarantee nutritional and sensory quality. The aim of this study is to adapt the high performance liquid chromatography (HPLC) method...

Full description

Bibliographic Details
Main Authors: Michelle Fernandes Silveira, Lourdes Maria Pessôa Masson, José Francisco Pereira Martins, Thiago da Silveira Álvares, Vânia Margaret Flosi Paschoalin, César Lázaro de la Torre, Carlos Adam Conte-Junior
Format: Article
Language:English
Published: Hindawi Limited 2015-01-01
Series:Journal of Chemistry
Online Access:http://dx.doi.org/10.1155/2015/185967
id doaj-3a81a06ac00e4d569159ec9828ca9867
record_format Article
spelling doaj-3a81a06ac00e4d569159ec9828ca98672020-11-24T22:32:40ZengHindawi LimitedJournal of Chemistry2090-90632090-90712015-01-01201510.1155/2015/185967185967Simultaneous Determination of Lactulose and Lactose in Conserved Milk by HPLC-RIDMichelle Fernandes Silveira0Lourdes Maria Pessôa Masson1José Francisco Pereira Martins2Thiago da Silveira Álvares3Vânia Margaret Flosi Paschoalin4César Lázaro de la Torre5Carlos Adam Conte-Junior6Federal Institute of Rio de Janeiro, No. 88, Pereira de Almeida Street, 20260-100 Praça da Bandeira, RJ, BrazilFederal Institute of Rio de Janeiro, No. 88, Pereira de Almeida Street, 20260-100 Praça da Bandeira, RJ, BrazilDepartment of Food Technology, Federal Rural University of Rio de Janeiro, 23890-000 Seropédica, RJ, BrazilInstitute of Nutrition, Federal University of Rio de Janeiro, Macaé Campus, Imburo Road, Ajuda, 27979-000 Macaé, RJ, BrazilInstitute of Nutrition, Federal University of Rio de Janeiro, Macaé Campus, Imburo Road, Ajuda, 27979-000 Macaé, RJ, BrazilLaboratory of Pharmacology and Toxicology, Faculty of Veterinary Medicine, Major National University of San Marcos, Circunvalación Avenue, San Borja, Lima 41, PeruInstitute of Nutrition, Federal University of Rio de Janeiro, Macaé Campus, Imburo Road, Ajuda, 27979-000 Macaé, RJ, BrazilHeat treatment is applied to dairy products to ensure microbiological quality and increase the shelf life. However, a suitable control of this process is necessary to guarantee nutritional and sensory quality. The aim of this study is to adapt the high performance liquid chromatography (HPLC) method for determination of lactulose and lactose content in commercial samples of UHT and sweetened condensed milk. The HPLC method used showed a good resolution of the analytes evaluated. The analyzed UHT milk samples presented levels for lactulose in accordance with the limit recommended by the International Dairy Federation. There was no significant variation in lactulose concentration for sweetened condensed milk samples. However, one sweetened condensed milk sample showed lactose level lower than the established values (10–12%).http://dx.doi.org/10.1155/2015/185967
collection DOAJ
language English
format Article
sources DOAJ
author Michelle Fernandes Silveira
Lourdes Maria Pessôa Masson
José Francisco Pereira Martins
Thiago da Silveira Álvares
Vânia Margaret Flosi Paschoalin
César Lázaro de la Torre
Carlos Adam Conte-Junior
spellingShingle Michelle Fernandes Silveira
Lourdes Maria Pessôa Masson
José Francisco Pereira Martins
Thiago da Silveira Álvares
Vânia Margaret Flosi Paschoalin
César Lázaro de la Torre
Carlos Adam Conte-Junior
Simultaneous Determination of Lactulose and Lactose in Conserved Milk by HPLC-RID
Journal of Chemistry
author_facet Michelle Fernandes Silveira
Lourdes Maria Pessôa Masson
José Francisco Pereira Martins
Thiago da Silveira Álvares
Vânia Margaret Flosi Paschoalin
César Lázaro de la Torre
Carlos Adam Conte-Junior
author_sort Michelle Fernandes Silveira
title Simultaneous Determination of Lactulose and Lactose in Conserved Milk by HPLC-RID
title_short Simultaneous Determination of Lactulose and Lactose in Conserved Milk by HPLC-RID
title_full Simultaneous Determination of Lactulose and Lactose in Conserved Milk by HPLC-RID
title_fullStr Simultaneous Determination of Lactulose and Lactose in Conserved Milk by HPLC-RID
title_full_unstemmed Simultaneous Determination of Lactulose and Lactose in Conserved Milk by HPLC-RID
title_sort simultaneous determination of lactulose and lactose in conserved milk by hplc-rid
publisher Hindawi Limited
series Journal of Chemistry
issn 2090-9063
2090-9071
publishDate 2015-01-01
description Heat treatment is applied to dairy products to ensure microbiological quality and increase the shelf life. However, a suitable control of this process is necessary to guarantee nutritional and sensory quality. The aim of this study is to adapt the high performance liquid chromatography (HPLC) method for determination of lactulose and lactose content in commercial samples of UHT and sweetened condensed milk. The HPLC method used showed a good resolution of the analytes evaluated. The analyzed UHT milk samples presented levels for lactulose in accordance with the limit recommended by the International Dairy Federation. There was no significant variation in lactulose concentration for sweetened condensed milk samples. However, one sweetened condensed milk sample showed lactose level lower than the established values (10–12%).
url http://dx.doi.org/10.1155/2015/185967
work_keys_str_mv AT michellefernandessilveira simultaneousdeterminationoflactuloseandlactoseinconservedmilkbyhplcrid
AT lourdesmariapessoamasson simultaneousdeterminationoflactuloseandlactoseinconservedmilkbyhplcrid
AT josefranciscopereiramartins simultaneousdeterminationoflactuloseandlactoseinconservedmilkbyhplcrid
AT thiagodasilveiraalvares simultaneousdeterminationoflactuloseandlactoseinconservedmilkbyhplcrid
AT vaniamargaretflosipaschoalin simultaneousdeterminationoflactuloseandlactoseinconservedmilkbyhplcrid
AT cesarlazarodelatorre simultaneousdeterminationoflactuloseandlactoseinconservedmilkbyhplcrid
AT carlosadamcontejunior simultaneousdeterminationoflactuloseandlactoseinconservedmilkbyhplcrid
_version_ 1725732832244924416