Influence of perfusion status on central and mixed venous oxygen saturation in septic patients

Background and objectives: Although there is controversy regarding the role of venous oxygen saturation in the initial resuscitation of septic patients with hypoperfusion these markers are still widely used. This study aimed to evaluate the correlation and concordance between central (SvcO2) and mix...

Full description

Bibliographic Details
Main Authors: Simone Harumi Goto, Bruno Franco Mazza, Flávio Geraldo Resende Freitas, Flávia Ribeiro Machado
Format: Article
Language:English
Published: Elsevier 2017-11-01
Series:Brazilian Journal of Anesthesiology
Online Access:http://www.sciencedirect.com/science/article/pii/S0104001417300210
id doaj-3bac0f3f1f484740a7cd8b2f76e37eb8
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Simone Harumi Goto
Bruno Franco Mazza
Flávio Geraldo Resende Freitas
Flávia Ribeiro Machado
spellingShingle Simone Harumi Goto
Bruno Franco Mazza
Flávio Geraldo Resende Freitas
Flávia Ribeiro Machado
Influence of perfusion status on central and mixed venous oxygen saturation in septic patients
Brazilian Journal of Anesthesiology
author_facet Simone Harumi Goto
Bruno Franco Mazza
Flávio Geraldo Resende Freitas
Flávia Ribeiro Machado
author_sort Simone Harumi Goto
title Influence of perfusion status on central and mixed venous oxygen saturation in septic patients
title_short Influence of perfusion status on central and mixed venous oxygen saturation in septic patients
title_full Influence of perfusion status on central and mixed venous oxygen saturation in septic patients
title_fullStr Influence of perfusion status on central and mixed venous oxygen saturation in septic patients
title_full_unstemmed Influence of perfusion status on central and mixed venous oxygen saturation in septic patients
title_sort influence of perfusion status on central and mixed venous oxygen saturation in septic patients
publisher Elsevier
series Brazilian Journal of Anesthesiology
issn 0104-0014
publishDate 2017-11-01
description Background and objectives: Although there is controversy regarding the role of venous oxygen saturation in the initial resuscitation of septic patients with hypoperfusion these markers are still widely used. This study aimed to evaluate the correlation and concordance between central (SvcO2) and mixed (SvO2) oxygen saturation in septic shock patients with or without hypoperfusion in addition to the impact of these differences in patient conduction. Methods: Patients with septic shock were monitored with pulmonary artery catheter and the following subgroups of hypoperfusion were analyzed: 1) lactate > 28 mg.dL−1; 2) base excess ≤ −5 mmol.L−1; 3) venoarterial CO2 gradient > 6 mmHg; 4) SvO2 < 65%; 5) SvcO2 < 70%; 6) lactate > 28 mg.dL−1 and SvO2 < 70%; 7) lactate > 28 mg.dL−1 and SvcO2 < 75%. Results: Seventy-seven samples from 24 patients were included. There was only a moderate correlation between SvO2 and SvcO2 (r = 0.72, p = 0.0001) and there was no good concordance between these variables (7.35% bias and 95% concordance limits of −3.0% to 17.7%). Subgroup analysis according to the presence of hypoperfusion showed no differences in concordance between variables. There was discordance regarding clinical management in 13.8% (n = 9) of the cases. Conclusions: There is a moderate correlation between SvO2 and SvcO2; however, the concordance between them is inadequate. It was not possible to demonstrate that the presence of hypoperfusion alters the concordance between SvO2 and SvcO2. The use of SvO2 instead of SvcO2 may lead to changes in clinical management in a small but clinically relevant portion of patients. Resumo: Justificativa e objetivos: Embora haja controvérsias sobre o papel das saturações venosas de oxigênio na ressuscitação inicial do paciente séptico com hipoperfusão, esses marcadores são ainda bastante usados. Este estudo procurou avaliar a correlação e a concordância entre as saturações venosas central (SvcO2) e mista (SvO2) de oxigênio em pacientes com choque séptico, na presença ou não de hipoperfusão, além do impacto dessas diferenças na condução clínica do paciente. Métodos: Foram incluídos pacientes com choque séptico monitorados com cateter de artéria pulmonar e analisados os seguintes subgrupos de hipoperfusão: 1) Lactato > 28 mg.dL−1; 2) Excesso de bases ≤ -5 mmoL.L−1; 3) Gradiente venoarterial de CO2 > 6 mmHg; 4) SvO2 < 65%; 5) SvcO2 < 70%; 6) Lactato > 28 mg.dL−1 e SvO2 < 70%; 7) Lactato > 28 mg.dL−1 e SvcO2 < 75%. Resultados: Foram incluídas 70 amostras de 24 pacientes. Houve apenas correlação moderada entre SvO2 e SvcO2 (r = 0,72; p = 0,0001) e não houve boa concordância entre essas variáveis (viés de 7,35% e limites de concordância de 95% de -3,0%-17,7%). A análise dos subgrupos de acordo com a presença de hipoperfusão não mostrou diferenças na concordância entre as variáveis. Houve discordância na conduta clínica em 13,8% dos casos (n = 9). Conclusões: Existe correlação moderada entre SvO2 e SvcO2, entretanto a concordância entre elas é inadequada. Não foi possível demonstrar que a presença de hipoperfusão altera a concordância entre a entre SvO2 e SvcO2. O uso da SvO2 em vez da SvcO2 pode levar a alterações na conduta clínica numa parcela pequena, porém clinicamente relevante, dos pacientes. Keywords: Sepsis, Venous oxygen saturation, Mixed oxygen saturation, Palavras-chave: Sepse, Saturação venosa de oxigênio, Saturação mista de oxigênio
url http://www.sciencedirect.com/science/article/pii/S0104001417300210
work_keys_str_mv AT simoneharumigoto influenceofperfusionstatusoncentralandmixedvenousoxygensaturationinsepticpatients
AT brunofrancomazza influenceofperfusionstatusoncentralandmixedvenousoxygensaturationinsepticpatients
AT flaviogeraldoresendefreitas influenceofperfusionstatusoncentralandmixedvenousoxygensaturationinsepticpatients
AT flaviaribeiromachado influenceofperfusionstatusoncentralandmixedvenousoxygensaturationinsepticpatients
_version_ 1724839413046837248
spelling doaj-3bac0f3f1f484740a7cd8b2f76e37eb82020-11-25T02:28:14ZengElsevierBrazilian Journal of Anesthesiology0104-00142017-11-01676607614Influence of perfusion status on central and mixed venous oxygen saturation in septic patientsSimone Harumi Goto0Bruno Franco Mazza1Flávio Geraldo Resende Freitas2Flávia Ribeiro Machado3Corresponding author.; Universidade Federal de São Paulo, Escola Paulista de Medicina, Hospital Universitário, São Paulo, SP, BrazilUniversidade Federal de São Paulo, Escola Paulista de Medicina, Hospital Universitário, São Paulo, SP, BrazilUniversidade Federal de São Paulo, Escola Paulista de Medicina, Hospital Universitário, São Paulo, SP, BrazilUniversidade Federal de São Paulo, Escola Paulista de Medicina, Hospital Universitário, São Paulo, SP, BrazilBackground and objectives: Although there is controversy regarding the role of venous oxygen saturation in the initial resuscitation of septic patients with hypoperfusion these markers are still widely used. This study aimed to evaluate the correlation and concordance between central (SvcO2) and mixed (SvO2) oxygen saturation in septic shock patients with or without hypoperfusion in addition to the impact of these differences in patient conduction. Methods: Patients with septic shock were monitored with pulmonary artery catheter and the following subgroups of hypoperfusion were analyzed: 1) lactate > 28 mg.dL−1; 2) base excess ≤ −5 mmol.L−1; 3) venoarterial CO2 gradient > 6 mmHg; 4) SvO2 < 65%; 5) SvcO2 < 70%; 6) lactate > 28 mg.dL−1 and SvO2 < 70%; 7) lactate > 28 mg.dL−1 and SvcO2 < 75%. Results: Seventy-seven samples from 24 patients were included. There was only a moderate correlation between SvO2 and SvcO2 (r = 0.72, p = 0.0001) and there was no good concordance between these variables (7.35% bias and 95% concordance limits of −3.0% to 17.7%). Subgroup analysis according to the presence of hypoperfusion showed no differences in concordance between variables. There was discordance regarding clinical management in 13.8% (n = 9) of the cases. Conclusions: There is a moderate correlation between SvO2 and SvcO2; however, the concordance between them is inadequate. It was not possible to demonstrate that the presence of hypoperfusion alters the concordance between SvO2 and SvcO2. The use of SvO2 instead of SvcO2 may lead to changes in clinical management in a small but clinically relevant portion of patients. Resumo: Justificativa e objetivos: Embora haja controvérsias sobre o papel das saturações venosas de oxigênio na ressuscitação inicial do paciente séptico com hipoperfusão, esses marcadores são ainda bastante usados. Este estudo procurou avaliar a correlação e a concordância entre as saturações venosas central (SvcO2) e mista (SvO2) de oxigênio em pacientes com choque séptico, na presença ou não de hipoperfusão, além do impacto dessas diferenças na condução clínica do paciente. Métodos: Foram incluídos pacientes com choque séptico monitorados com cateter de artéria pulmonar e analisados os seguintes subgrupos de hipoperfusão: 1) Lactato > 28 mg.dL−1; 2) Excesso de bases ≤ -5 mmoL.L−1; 3) Gradiente venoarterial de CO2 > 6 mmHg; 4) SvO2 < 65%; 5) SvcO2 < 70%; 6) Lactato > 28 mg.dL−1 e SvO2 < 70%; 7) Lactato > 28 mg.dL−1 e SvcO2 < 75%. Resultados: Foram incluídas 70 amostras de 24 pacientes. Houve apenas correlação moderada entre SvO2 e SvcO2 (r = 0,72; p = 0,0001) e não houve boa concordância entre essas variáveis (viés de 7,35% e limites de concordância de 95% de -3,0%-17,7%). A análise dos subgrupos de acordo com a presença de hipoperfusão não mostrou diferenças na concordância entre as variáveis. Houve discordância na conduta clínica em 13,8% dos casos (n = 9). Conclusões: Existe correlação moderada entre SvO2 e SvcO2, entretanto a concordância entre elas é inadequada. Não foi possível demonstrar que a presença de hipoperfusão altera a concordância entre a entre SvO2 e SvcO2. O uso da SvO2 em vez da SvcO2 pode levar a alterações na conduta clínica numa parcela pequena, porém clinicamente relevante, dos pacientes. Keywords: Sepsis, Venous oxygen saturation, Mixed oxygen saturation, Palavras-chave: Sepse, Saturação venosa de oxigênio, Saturação mista de oxigêniohttp://www.sciencedirect.com/science/article/pii/S0104001417300210