Techno-Economic Analysis of Off-Grid Hybrid PV-Diesel-Battery System in Katsina State, Nigeria

Continuous burning of fossil fuel has a great impact on the environment. Thus, moving toward renewable energy system or hybridization of alternative energy systems can reduce the emission of hazardous gases produced by the fossil fuels. This paper presents a techno-economic analysis of hybrid PV/die...

Full description

Bibliographic Details
Main Authors: B. Modu, A. K. Aliyu, A. L. Bukar, M. Abdulkadir, Z. M. Gwoma, M. Mustapha
Format: Article
Language:English
Published: University of Maiduguri 2018-06-01
Series:Arid Zone Journal of Engineering, Technology and Environment
Online Access:http://azojete.com.ng/index.php/azojete/article/view/407
id doaj-3d4eaa4081384938a8dac9900813d659
record_format Article
spelling doaj-3d4eaa4081384938a8dac9900813d6592020-11-25T02:02:49ZengUniversity of MaiduguriArid Zone Journal of Engineering, Technology and Environment2545-58182545-58182018-06-01142317324Techno-Economic Analysis of Off-Grid Hybrid PV-Diesel-Battery System in Katsina State, NigeriaB. Modu0A. K. Aliyu1A. L. Bukar2M. Abdulkadir3Z. M. Gwoma4M. Mustapha5Department of Electrical and Electronics Engineering, Faculty of Engineering, University of Maiduguri, Maiduguri, NigeriaDepartment of Electrical Engineering, Murtala Muhammed Airport, Federal Airports Authority of Nigeria, Ikeja LagosDepartment of Electrical and Electronics Engineering, Faculty of Engineering, University of Maiduguri, Maiduguri, NigeriaDepartment of Electrical and Electronics Engineering, Faculty of Engineering, University of Maiduguri, Maiduguri, NigeriaDepartment of Electrical and Electronics Engineering, Faculty of Engineering, University of Maiduguri, Maiduguri, NigeriaDepartment of Electrical and Electronics Engineering, Faculty of Engineering, University of Maiduguri, Maiduguri, NigeriaContinuous burning of fossil fuel has a great impact on the environment. Thus, moving toward renewable energy system or hybridization of alternative energy systems can reduce the emission of hazardous gases produced by the fossil fuels. This paper presents a techno-economic analysis of hybrid PV/diesel and battery system configuration of five (5) Houses at Barhim Quarters, Katsina, Nigeria. HOMER optimization software was used for the techno-economic analysis. This paper shows how a meaningful amount of CO2 can be reduce and the impact of PV penetration by the optimized hybrid PV/diesel system configuration. Having compared the configurations such as the PV-diesel-battery, PV-diesel without battery, Standalone diesel and standalone PV system based with $0.434/kW, $0.645/kW, $0.721/kW and $0.908/kW respectively as their cost of energy. Considering the Net present costs, cost of energy, CO2 emission, excess of electricity generated and renewable penetration, a PV-diesel-battery Hybrid Power System (HPS) was proposed for the area under focus.http://azojete.com.ng/index.php/azojete/article/view/407
collection DOAJ
language English
format Article
sources DOAJ
author B. Modu
A. K. Aliyu
A. L. Bukar
M. Abdulkadir
Z. M. Gwoma
M. Mustapha
spellingShingle B. Modu
A. K. Aliyu
A. L. Bukar
M. Abdulkadir
Z. M. Gwoma
M. Mustapha
Techno-Economic Analysis of Off-Grid Hybrid PV-Diesel-Battery System in Katsina State, Nigeria
Arid Zone Journal of Engineering, Technology and Environment
author_facet B. Modu
A. K. Aliyu
A. L. Bukar
M. Abdulkadir
Z. M. Gwoma
M. Mustapha
author_sort B. Modu
title Techno-Economic Analysis of Off-Grid Hybrid PV-Diesel-Battery System in Katsina State, Nigeria
title_short Techno-Economic Analysis of Off-Grid Hybrid PV-Diesel-Battery System in Katsina State, Nigeria
title_full Techno-Economic Analysis of Off-Grid Hybrid PV-Diesel-Battery System in Katsina State, Nigeria
title_fullStr Techno-Economic Analysis of Off-Grid Hybrid PV-Diesel-Battery System in Katsina State, Nigeria
title_full_unstemmed Techno-Economic Analysis of Off-Grid Hybrid PV-Diesel-Battery System in Katsina State, Nigeria
title_sort techno-economic analysis of off-grid hybrid pv-diesel-battery system in katsina state, nigeria
publisher University of Maiduguri
series Arid Zone Journal of Engineering, Technology and Environment
issn 2545-5818
2545-5818
publishDate 2018-06-01
description Continuous burning of fossil fuel has a great impact on the environment. Thus, moving toward renewable energy system or hybridization of alternative energy systems can reduce the emission of hazardous gases produced by the fossil fuels. This paper presents a techno-economic analysis of hybrid PV/diesel and battery system configuration of five (5) Houses at Barhim Quarters, Katsina, Nigeria. HOMER optimization software was used for the techno-economic analysis. This paper shows how a meaningful amount of CO2 can be reduce and the impact of PV penetration by the optimized hybrid PV/diesel system configuration. Having compared the configurations such as the PV-diesel-battery, PV-diesel without battery, Standalone diesel and standalone PV system based with $0.434/kW, $0.645/kW, $0.721/kW and $0.908/kW respectively as their cost of energy. Considering the Net present costs, cost of energy, CO2 emission, excess of electricity generated and renewable penetration, a PV-diesel-battery Hybrid Power System (HPS) was proposed for the area under focus.
url http://azojete.com.ng/index.php/azojete/article/view/407
work_keys_str_mv AT bmodu technoeconomicanalysisofoffgridhybridpvdieselbatterysysteminkatsinastatenigeria
AT akaliyu technoeconomicanalysisofoffgridhybridpvdieselbatterysysteminkatsinastatenigeria
AT albukar technoeconomicanalysisofoffgridhybridpvdieselbatterysysteminkatsinastatenigeria
AT mabdulkadir technoeconomicanalysisofoffgridhybridpvdieselbatterysysteminkatsinastatenigeria
AT zmgwoma technoeconomicanalysisofoffgridhybridpvdieselbatterysysteminkatsinastatenigeria
AT mmustapha technoeconomicanalysisofoffgridhybridpvdieselbatterysysteminkatsinastatenigeria
_version_ 1724951266203795456