Intergranular Corrosion of Low Cr Ferritic Stainless Steel 429 Evaluated by the Optimized Double Loop Electrochemical Potentiokinetic Reactivation Test
Intergranular corrosion (IGC) of Nb-Ti stabilized ferritic stainless steel (FSS) 429 was investigated using the double loop electrochemical potentiokinetic reactivation (DL-EPR) test combined with the microstructure observation. The results indicated that the optimized DL-EPR test condition for FSS...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2015-01-01
|
Series: | Advances in Materials Science and Engineering |
Online Access: | http://dx.doi.org/10.1155/2015/716874 |
Summary: | Intergranular corrosion (IGC) of Nb-Ti stabilized ferritic stainless steel (FSS) 429 was investigated using the double loop electrochemical potentiokinetic reactivation (DL-EPR) test combined with the microstructure observation. The results indicated that the optimized DL-EPR test condition for FSS 429 was the solution of 0.5 M H2SO4 + 0.0001 M KSCN with a scanning rate of 100 mV/min at 30°C. Based on this condition, the specimens aging at 400–700°C for different duration were tested and a time-temperature-sensitization (TTS) curve for FSS 429 was obtained, which reveals the sensitization nose was located around 550°C. The critical Ir/Ia value was determined to be about 3% above which IGC occurred. After aging treatment, Cr depletion zone was detected using energy dispersive spectroscopy (EDS), most possibly due to Cr segregation around intergranular TiC and NbC. |
---|---|
ISSN: | 1687-8434 1687-8442 |