THEORETICAL AND EXPERIMENTAL STUDY OF THERMAL PERFORMANCE WITHIN A COUNTERFLOW WET COOLING TOWER

This study is interested on experimental and theoretical of heat and mass transfer phenomena in a counter-flow wet cooling tower. A simplified thermal model has been used to simulate the thermal behavior and the performance of the tower. The calculation of the heat and mass transfer parameters to de...

Full description

Bibliographic Details
Main Authors: N. MENECEUR, S. BOULAHROUZ, K. KHOUNFAIS, A. BOUKHARI
Format: Article
Language:English
Published: Taylor's University 2018-11-01
Series:Journal of Engineering Science and Technology
Subjects:
Online Access:http://jestec.taylors.edu.my/Vol%2013%20issue%2011%20November%202018/13_11_18.pdf
id doaj-3ebd3000648f4680bd6c8260656ddc70
record_format Article
spelling doaj-3ebd3000648f4680bd6c8260656ddc702020-11-25T00:07:57ZengTaylor's UniversityJournal of Engineering Science and Technology1823-46902018-11-01131136913709THEORETICAL AND EXPERIMENTAL STUDY OF THERMAL PERFORMANCE WITHIN A COUNTERFLOW WET COOLING TOWERN. MENECEUR0S. BOULAHROUZ1K. KHOUNFAIS2A. BOUKHARI3Dept. of Mechanical Engineering, Faculty of Technology, El-Oued University, AlgeriaElectro-Mechanical Engineering laboratory, Faculty of Science and Technology, Khenchela University, AlgeriaDept. of Physics, Faculty of Exact Sciences, Skikda University, AlgeriaDept. of Mechanical Engineering, Faculty of Technology, El-Oued University, AlgeriaThis study is interested on experimental and theoretical of heat and mass transfer phenomena in a counter-flow wet cooling tower. A simplified thermal model has been used to simulate the thermal behavior and the performance of the tower. The calculation of the heat and mass transfer parameters to determine the characteristics of the good operation of the tower. Eight experimental manipulations were conducted to study the influence of various parameters (such as: thermal cooling load, the flow of water and air) on the thermal performance of the tower. The results obtained show that the increase in cooling load contributes to a considerable reduction in the effectiveness of the tower, as well as the increase in the water flow is used to decrease the performance of the tower, while the increase in airflow is used to improve considerably the different parameters of performance. It can be seen that the results obtained by simulation coincide quite well with the experimental results. The minor discrepancies between the present simulation and experimental measurements can be attributed to the measurements uncertainties and simulation accuracy.http://jestec.taylors.edu.my/Vol%2013%20issue%2011%20November%202018/13_11_18.pdfCooling towerExperimentsHeat transferMass transferModeling
collection DOAJ
language English
format Article
sources DOAJ
author N. MENECEUR
S. BOULAHROUZ
K. KHOUNFAIS
A. BOUKHARI
spellingShingle N. MENECEUR
S. BOULAHROUZ
K. KHOUNFAIS
A. BOUKHARI
THEORETICAL AND EXPERIMENTAL STUDY OF THERMAL PERFORMANCE WITHIN A COUNTERFLOW WET COOLING TOWER
Journal of Engineering Science and Technology
Cooling tower
Experiments
Heat transfer
Mass transfer
Modeling
author_facet N. MENECEUR
S. BOULAHROUZ
K. KHOUNFAIS
A. BOUKHARI
author_sort N. MENECEUR
title THEORETICAL AND EXPERIMENTAL STUDY OF THERMAL PERFORMANCE WITHIN A COUNTERFLOW WET COOLING TOWER
title_short THEORETICAL AND EXPERIMENTAL STUDY OF THERMAL PERFORMANCE WITHIN A COUNTERFLOW WET COOLING TOWER
title_full THEORETICAL AND EXPERIMENTAL STUDY OF THERMAL PERFORMANCE WITHIN A COUNTERFLOW WET COOLING TOWER
title_fullStr THEORETICAL AND EXPERIMENTAL STUDY OF THERMAL PERFORMANCE WITHIN A COUNTERFLOW WET COOLING TOWER
title_full_unstemmed THEORETICAL AND EXPERIMENTAL STUDY OF THERMAL PERFORMANCE WITHIN A COUNTERFLOW WET COOLING TOWER
title_sort theoretical and experimental study of thermal performance within a counterflow wet cooling tower
publisher Taylor's University
series Journal of Engineering Science and Technology
issn 1823-4690
publishDate 2018-11-01
description This study is interested on experimental and theoretical of heat and mass transfer phenomena in a counter-flow wet cooling tower. A simplified thermal model has been used to simulate the thermal behavior and the performance of the tower. The calculation of the heat and mass transfer parameters to determine the characteristics of the good operation of the tower. Eight experimental manipulations were conducted to study the influence of various parameters (such as: thermal cooling load, the flow of water and air) on the thermal performance of the tower. The results obtained show that the increase in cooling load contributes to a considerable reduction in the effectiveness of the tower, as well as the increase in the water flow is used to decrease the performance of the tower, while the increase in airflow is used to improve considerably the different parameters of performance. It can be seen that the results obtained by simulation coincide quite well with the experimental results. The minor discrepancies between the present simulation and experimental measurements can be attributed to the measurements uncertainties and simulation accuracy.
topic Cooling tower
Experiments
Heat transfer
Mass transfer
Modeling
url http://jestec.taylors.edu.my/Vol%2013%20issue%2011%20November%202018/13_11_18.pdf
work_keys_str_mv AT nmeneceur theoreticalandexperimentalstudyofthermalperformancewithinacounterflowwetcoolingtower
AT sboulahrouz theoreticalandexperimentalstudyofthermalperformancewithinacounterflowwetcoolingtower
AT kkhounfais theoreticalandexperimentalstudyofthermalperformancewithinacounterflowwetcoolingtower
AT aboukhari theoreticalandexperimentalstudyofthermalperformancewithinacounterflowwetcoolingtower
_version_ 1725417503265390592