Analysis and design of 40 m high steel chimney according to Eurocode and SRPS standards
This paper presents structural analysis according to Eurocode and SRPS standards. Analysed construction is 40 m high steel chimney, made of 33 m long upper circular cross-section segment of constant diameter D=1834 mm and bottom variable circular cross-section segment of D=2234 mm on the foundation...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of civil engineering, Subotica
2015-01-01
|
Series: | Zbornik Radova Građevinskog Fakulteta |
Subjects: | |
Online Access: | http://scindeks-clanci.ceon.rs/data/pdf/0352-6852/2015/0352-68521527007B.pdf |
id |
doaj-3f58b8019c9f4cc3997ffb861b205ed2 |
---|---|
record_format |
Article |
spelling |
doaj-3f58b8019c9f4cc3997ffb861b205ed22020-11-24T21:00:40ZengFaculty of civil engineering, SuboticaZbornik Radova Građevinskog Fakulteta0352-68522334-95732015-01-012015277200352-68521527007BAnalysis and design of 40 m high steel chimney according to Eurocode and SRPS standardsBešević Miroslav T.0Landović Aleksandar1Prokić Aleksandar2Tabaković Dragana3Tešanović Aniko4University of Novi Sad, Faculty of Civil Engineering, Subotica, SerbiaUniversity of Novi Sad, Faculty of Civil Engineering, Subotica, SerbiaUniversity of Novi Sad, Faculty of Civil Engineering, Subotica, SerbiaUniversity of Novi Sad, Faculty of Civil Engineering, Subotica, SerbiaUniversity of Novi Sad, Faculty of Civil Engineering, Subotica, SerbiaThis paper presents structural analysis according to Eurocode and SRPS standards. Analysed construction is 40 m high steel chimney, made of 33 m long upper circular cross-section segment of constant diameter D=1834 mm and bottom variable circular cross-section segment of D=2234 mm on the foundation level. Wind loads are dominant loads for this kind of structures. In analyzing workload basic wind speed is thoroughly treated according to SRPS U.C7.110, and respectively wind speed is treated according to Eurocode 1 for the location of Prahovo. Design of model for the effects of its own weight, a constant load and wind load was conducted according to the second order theory for pre-formed load combinations. The load combinations do not contain partial load safety factors. Design of chimney shaft segments are carried out for different ticknes by height of the pillar, for bearing capacity of cross-section, buckling due normal stress, buckling due tangential stress and buckling control is carried out due shear stress.http://scindeks-clanci.ceon.rs/data/pdf/0352-6852/2015/0352-68521527007B.pdfloadswind effectscalculationdesignstandards |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Bešević Miroslav T. Landović Aleksandar Prokić Aleksandar Tabaković Dragana Tešanović Aniko |
spellingShingle |
Bešević Miroslav T. Landović Aleksandar Prokić Aleksandar Tabaković Dragana Tešanović Aniko Analysis and design of 40 m high steel chimney according to Eurocode and SRPS standards Zbornik Radova Građevinskog Fakulteta loads wind effects calculation design standards |
author_facet |
Bešević Miroslav T. Landović Aleksandar Prokić Aleksandar Tabaković Dragana Tešanović Aniko |
author_sort |
Bešević Miroslav T. |
title |
Analysis and design of 40 m high steel chimney according to Eurocode and SRPS standards |
title_short |
Analysis and design of 40 m high steel chimney according to Eurocode and SRPS standards |
title_full |
Analysis and design of 40 m high steel chimney according to Eurocode and SRPS standards |
title_fullStr |
Analysis and design of 40 m high steel chimney according to Eurocode and SRPS standards |
title_full_unstemmed |
Analysis and design of 40 m high steel chimney according to Eurocode and SRPS standards |
title_sort |
analysis and design of 40 m high steel chimney according to eurocode and srps standards |
publisher |
Faculty of civil engineering, Subotica |
series |
Zbornik Radova Građevinskog Fakulteta |
issn |
0352-6852 2334-9573 |
publishDate |
2015-01-01 |
description |
This paper presents structural analysis according to Eurocode and SRPS standards. Analysed construction is 40 m high steel chimney, made of 33 m long upper circular cross-section segment of constant diameter D=1834 mm and bottom variable circular cross-section segment of D=2234 mm on the foundation level. Wind loads are dominant loads for this kind of structures. In analyzing workload basic wind speed is thoroughly treated according to SRPS U.C7.110, and respectively wind speed is treated according to Eurocode 1 for the location of Prahovo. Design of model for the effects of its own weight, a constant load and wind load was conducted according to the second order theory for pre-formed load combinations. The load combinations do not contain partial load safety factors. Design of chimney shaft segments are carried out for different ticknes by height of the pillar, for bearing capacity of cross-section, buckling due normal stress, buckling due tangential stress and buckling control is carried out due shear stress. |
topic |
loads wind effects calculation design standards |
url |
http://scindeks-clanci.ceon.rs/data/pdf/0352-6852/2015/0352-68521527007B.pdf |
work_keys_str_mv |
AT besevicmiroslavt analysisanddesignof40mhighsteelchimneyaccordingtoeurocodeandsrpsstandards AT landovicaleksandar analysisanddesignof40mhighsteelchimneyaccordingtoeurocodeandsrpsstandards AT prokicaleksandar analysisanddesignof40mhighsteelchimneyaccordingtoeurocodeandsrpsstandards AT tabakovicdragana analysisanddesignof40mhighsteelchimneyaccordingtoeurocodeandsrpsstandards AT tesanovicaniko analysisanddesignof40mhighsteelchimneyaccordingtoeurocodeandsrpsstandards |
_version_ |
1716779002067156992 |