Stenosis Detection in Internal Carotid and Vertebral Arteries With the Use of Diameters Estimated from MRI Data

Background. Magnetic resonance imaging (MRI) offers the opportunity to quantify the vessel diameters in vivo. This technique can have a breakthrough impact on the evaluation, risk stratification and therapeutical planning in hemodynamic-related pathologies, e.g., arterial stenosis. However, its appl...

Full description

Bibliographic Details
Main Authors: Igor Nesteruk, Sergiy Jr. Pereverzyev, Lukas Mayer, Ruth Steiger, Lukas Kusstatscher, Karl Fritscher, Michael Knoflach, Elke Ruth Gizewski
Format: Article
Language:English
Published: Igor Sikorsky Kyiv Polytechnic Institute 2020-07-01
Series:Innovative Biosystems and Bioengineering
Subjects:
Online Access:http://ibb.kpi.ua/article/view/207624
id doaj-3f68d183e4b244a88151b32c07564e1b
record_format Article
spelling doaj-3f68d183e4b244a88151b32c07564e1b2021-04-02T12:49:57ZengIgor Sikorsky Kyiv Polytechnic InstituteInnovative Biosystems and Bioengineering2616-177X2020-07-014313114210.20535/ibb.2020.4.3.207624207624Stenosis Detection in Internal Carotid and Vertebral Arteries With the Use of Diameters Estimated from MRI DataIgor Nesteruk0Sergiy Jr. Pereverzyev1Lukas Mayer2Ruth Steiger3Lukas Kusstatscher4Karl Fritscher5Michael Knoflach6Elke Ruth Gizewski7Igor Sikorsky Kyiv Polytechnic InstituteMedical University of InnsbruckMedical University of InnsbruckMedical University of InnsbruckMedical University of InnsbruckUniversity for Health Sciences, Medical Informatics and TechnologyMedical University of InnsbruckMedical University InnsbruckBackground. Magnetic resonance imaging (MRI) offers the opportunity to quantify the vessel diameters in vivo. This technique can have a breakthrough impact on the evaluation, risk stratification and therapeutical planning in hemodynamic-related pathologies, e.g., arterial stenosis. However, its applicability in clinics is limi­ted due to the complex post-processing required to extract the information and the difficulty to synthesize the obtained data into clinical useful parameters. Objective. In this work, we use the vessel diameter distribution along its central line obtained with the use of MRI technology in order to detect the existence of stenosis in internal carotid arteries (ICA) and vertebral arteries (VA) with the minimal amount of False Negative predictions and to estimate the efficiency of therapy. Methods. Special normalized and smoothed characteristics will be used to develop the stenosis detection criteria which can be used for every artery separately and for both vessels simultaneously. Linear and non-linear characteristics were used to increase the reliability of diagnostics. Study is based on the Receiver Operating Characteristics (ROC) and optimization methods. Real diameter data of 10 patients (80 data sets) were used. Results. To detect stenosis, three different criteria have been proposed, based on the optimal smoothing parameters of vessel diameter distributions and the corresponding threshold values for linear and nonlinear characteristics. The use of the developed criteria allows increasing the reliability of stenosis detection. Conclusions. Different linear, non-linear, smoothed and non-smoothed parameters and ROC were applied to detect stenosis in internal carotid and vertebral arteries. It was shown that smoothed data are necessary for VA and the criterion applicable both for VA and ICA. For ICA it is possible to use initial (unsmoothed) data. Only one False Positive case was detected for every artery. Results of application of proposed criteria are presented, tested and discussed. For VA it is possible to use criteria 1 and 2 and smoothed normalized diameter data. For ICA criterion 2 can be recommended to detect long enough narrowing areas. To detect short zones of stenosis in ICA, the criterion 3 is useful, since it uses the non-smoothed diameter data.http://ibb.kpi.ua/article/view/207624stenosisinternal carotid arteriesvertebral arteriesmagnetic resonance imagingcomputerized angiographyreceiver operating characteristicoptimization
collection DOAJ
language English
format Article
sources DOAJ
author Igor Nesteruk
Sergiy Jr. Pereverzyev
Lukas Mayer
Ruth Steiger
Lukas Kusstatscher
Karl Fritscher
Michael Knoflach
Elke Ruth Gizewski
spellingShingle Igor Nesteruk
Sergiy Jr. Pereverzyev
Lukas Mayer
Ruth Steiger
Lukas Kusstatscher
Karl Fritscher
Michael Knoflach
Elke Ruth Gizewski
Stenosis Detection in Internal Carotid and Vertebral Arteries With the Use of Diameters Estimated from MRI Data
Innovative Biosystems and Bioengineering
stenosis
internal carotid arteries
vertebral arteries
magnetic resonance imaging
computerized angiography
receiver operating characteristic
optimization
author_facet Igor Nesteruk
Sergiy Jr. Pereverzyev
Lukas Mayer
Ruth Steiger
Lukas Kusstatscher
Karl Fritscher
Michael Knoflach
Elke Ruth Gizewski
author_sort Igor Nesteruk
title Stenosis Detection in Internal Carotid and Vertebral Arteries With the Use of Diameters Estimated from MRI Data
title_short Stenosis Detection in Internal Carotid and Vertebral Arteries With the Use of Diameters Estimated from MRI Data
title_full Stenosis Detection in Internal Carotid and Vertebral Arteries With the Use of Diameters Estimated from MRI Data
title_fullStr Stenosis Detection in Internal Carotid and Vertebral Arteries With the Use of Diameters Estimated from MRI Data
title_full_unstemmed Stenosis Detection in Internal Carotid and Vertebral Arteries With the Use of Diameters Estimated from MRI Data
title_sort stenosis detection in internal carotid and vertebral arteries with the use of diameters estimated from mri data
publisher Igor Sikorsky Kyiv Polytechnic Institute
series Innovative Biosystems and Bioengineering
issn 2616-177X
publishDate 2020-07-01
description Background. Magnetic resonance imaging (MRI) offers the opportunity to quantify the vessel diameters in vivo. This technique can have a breakthrough impact on the evaluation, risk stratification and therapeutical planning in hemodynamic-related pathologies, e.g., arterial stenosis. However, its applicability in clinics is limi­ted due to the complex post-processing required to extract the information and the difficulty to synthesize the obtained data into clinical useful parameters. Objective. In this work, we use the vessel diameter distribution along its central line obtained with the use of MRI technology in order to detect the existence of stenosis in internal carotid arteries (ICA) and vertebral arteries (VA) with the minimal amount of False Negative predictions and to estimate the efficiency of therapy. Methods. Special normalized and smoothed characteristics will be used to develop the stenosis detection criteria which can be used for every artery separately and for both vessels simultaneously. Linear and non-linear characteristics were used to increase the reliability of diagnostics. Study is based on the Receiver Operating Characteristics (ROC) and optimization methods. Real diameter data of 10 patients (80 data sets) were used. Results. To detect stenosis, three different criteria have been proposed, based on the optimal smoothing parameters of vessel diameter distributions and the corresponding threshold values for linear and nonlinear characteristics. The use of the developed criteria allows increasing the reliability of stenosis detection. Conclusions. Different linear, non-linear, smoothed and non-smoothed parameters and ROC were applied to detect stenosis in internal carotid and vertebral arteries. It was shown that smoothed data are necessary for VA and the criterion applicable both for VA and ICA. For ICA it is possible to use initial (unsmoothed) data. Only one False Positive case was detected for every artery. Results of application of proposed criteria are presented, tested and discussed. For VA it is possible to use criteria 1 and 2 and smoothed normalized diameter data. For ICA criterion 2 can be recommended to detect long enough narrowing areas. To detect short zones of stenosis in ICA, the criterion 3 is useful, since it uses the non-smoothed diameter data.
topic stenosis
internal carotid arteries
vertebral arteries
magnetic resonance imaging
computerized angiography
receiver operating characteristic
optimization
url http://ibb.kpi.ua/article/view/207624
work_keys_str_mv AT igornesteruk stenosisdetectionininternalcarotidandvertebralarterieswiththeuseofdiametersestimatedfrommridata
AT sergiyjrpereverzyev stenosisdetectionininternalcarotidandvertebralarterieswiththeuseofdiametersestimatedfrommridata
AT lukasmayer stenosisdetectionininternalcarotidandvertebralarterieswiththeuseofdiametersestimatedfrommridata
AT ruthsteiger stenosisdetectionininternalcarotidandvertebralarterieswiththeuseofdiametersestimatedfrommridata
AT lukaskusstatscher stenosisdetectionininternalcarotidandvertebralarterieswiththeuseofdiametersestimatedfrommridata
AT karlfritscher stenosisdetectionininternalcarotidandvertebralarterieswiththeuseofdiametersestimatedfrommridata
AT michaelknoflach stenosisdetectionininternalcarotidandvertebralarterieswiththeuseofdiametersestimatedfrommridata
AT elkeruthgizewski stenosisdetectionininternalcarotidandvertebralarterieswiththeuseofdiametersestimatedfrommridata
_version_ 1721567406572175360