Nonlinear ultrasonic imaging in pulse-echo mode using Westervelt equation: a preliminary research

Acoustic nonlinear parameter β, was of great interest in tissue characterization in recent years. Nonlinear imaging methods have been reported to provide improved spatial and contrast resolution. We introduce a nonlinear imaging method derived from nonlinear wave equation based on Gaussian-form solu...

Full description

Bibliographic Details
Main Authors: Wuxuan Chen, Peng Wang, Zhihong Zhang, Xudong Deng, Congyao Zhang, Shenggen Ju
Format: Article
Language:English
Published: Taylor & Francis Group 2019-10-01
Series:Computer Assisted Surgery
Subjects:
Online Access:http://dx.doi.org/10.1080/24699322.2019.1649065
id doaj-410958ee41a84c95a1378b35a10ca617
record_format Article
spelling doaj-410958ee41a84c95a1378b35a10ca6172020-11-24T21:48:58ZengTaylor & Francis GroupComputer Assisted Surgery2469-93222019-10-01240546110.1080/24699322.2019.16490651649065Nonlinear ultrasonic imaging in pulse-echo mode using Westervelt equation: a preliminary researchWuxuan Chen0Peng Wang1Zhihong Zhang2Xudong Deng3Congyao Zhang4Shenggen Ju5Sichuan UniversitySichuan UniversityChangsha UniversityChangsha UniversitySichuan UniversitySichuan UniversityAcoustic nonlinear parameter β, was of great interest in tissue characterization in recent years. Nonlinear imaging methods have been reported to provide improved spatial and contrast resolution. We introduce a nonlinear imaging method derived from nonlinear wave equation based on Gaussian-form solution assumption, which can be applied in pulse-echo mode on diagnostic ultrasound. Through making the use of two pulse transmission, only nonlinear effects are reserved and other effects like scattering, diffraction and linear attenuation can be eliminated. For validation of this method a set of simulation results are generated with a nonlinear simulator. Simulated images also indicate that our method clearly describes the spatial distribution of B/A in the medium.http://dx.doi.org/10.1080/24699322.2019.1649065Nonlinear effectsnonlinear parameter imaging two-pulse transmissionpulse-echo modediagnostic ultrasound
collection DOAJ
language English
format Article
sources DOAJ
author Wuxuan Chen
Peng Wang
Zhihong Zhang
Xudong Deng
Congyao Zhang
Shenggen Ju
spellingShingle Wuxuan Chen
Peng Wang
Zhihong Zhang
Xudong Deng
Congyao Zhang
Shenggen Ju
Nonlinear ultrasonic imaging in pulse-echo mode using Westervelt equation: a preliminary research
Computer Assisted Surgery
Nonlinear effects
nonlinear parameter imaging
two-pulse transmission
pulse-echo mode
diagnostic ultrasound
author_facet Wuxuan Chen
Peng Wang
Zhihong Zhang
Xudong Deng
Congyao Zhang
Shenggen Ju
author_sort Wuxuan Chen
title Nonlinear ultrasonic imaging in pulse-echo mode using Westervelt equation: a preliminary research
title_short Nonlinear ultrasonic imaging in pulse-echo mode using Westervelt equation: a preliminary research
title_full Nonlinear ultrasonic imaging in pulse-echo mode using Westervelt equation: a preliminary research
title_fullStr Nonlinear ultrasonic imaging in pulse-echo mode using Westervelt equation: a preliminary research
title_full_unstemmed Nonlinear ultrasonic imaging in pulse-echo mode using Westervelt equation: a preliminary research
title_sort nonlinear ultrasonic imaging in pulse-echo mode using westervelt equation: a preliminary research
publisher Taylor & Francis Group
series Computer Assisted Surgery
issn 2469-9322
publishDate 2019-10-01
description Acoustic nonlinear parameter β, was of great interest in tissue characterization in recent years. Nonlinear imaging methods have been reported to provide improved spatial and contrast resolution. We introduce a nonlinear imaging method derived from nonlinear wave equation based on Gaussian-form solution assumption, which can be applied in pulse-echo mode on diagnostic ultrasound. Through making the use of two pulse transmission, only nonlinear effects are reserved and other effects like scattering, diffraction and linear attenuation can be eliminated. For validation of this method a set of simulation results are generated with a nonlinear simulator. Simulated images also indicate that our method clearly describes the spatial distribution of B/A in the medium.
topic Nonlinear effects
nonlinear parameter imaging
two-pulse transmission
pulse-echo mode
diagnostic ultrasound
url http://dx.doi.org/10.1080/24699322.2019.1649065
work_keys_str_mv AT wuxuanchen nonlinearultrasonicimaginginpulseechomodeusingwesterveltequationapreliminaryresearch
AT pengwang nonlinearultrasonicimaginginpulseechomodeusingwesterveltequationapreliminaryresearch
AT zhihongzhang nonlinearultrasonicimaginginpulseechomodeusingwesterveltequationapreliminaryresearch
AT xudongdeng nonlinearultrasonicimaginginpulseechomodeusingwesterveltequationapreliminaryresearch
AT congyaozhang nonlinearultrasonicimaginginpulseechomodeusingwesterveltequationapreliminaryresearch
AT shenggenju nonlinearultrasonicimaginginpulseechomodeusingwesterveltequationapreliminaryresearch
_version_ 1725890287462514688