A clinical evaluation of two electronic apex locators and conventional radiography in working length determination in primary molar and its influence on children's behavioral responses

Background: Accurate root canal length determination, simplicity of the procedure, and patient's cooperation are important determinants in the success of endodontic treatment in primary teeth. Aim: The aim of the study was to clinically compare the accuracy of Propex Pixi and Formatron D10 apex...

Full description

Bibliographic Details
Main Authors: Krithi Nellamakkada, Sandya S Patil, Madhu Kakanur, Ravi S Kumar, Rachna Thakur
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2020-01-01
Series:Journal of Indian Society of Pedodontics and Preventive Dentistry
Subjects:
Online Access:http://www.jisppd.com/article.asp?issn=0970-4388;year=2020;volume=38;issue=2;spage=158;epage=163;aulast=Nellamakkada
id doaj-421852a66c364d70af61daf1557840e6
record_format Article
spelling doaj-421852a66c364d70af61daf1557840e62020-11-25T02:59:48ZengWolters Kluwer Medknow PublicationsJournal of Indian Society of Pedodontics and Preventive Dentistry0970-43881998-39052020-01-0138215816310.4103/JISPPD.JISPPD_28_20A clinical evaluation of two electronic apex locators and conventional radiography in working length determination in primary molar and its influence on children's behavioral responsesKrithi NellamakkadaSandya S PatilMadhu KakanurRavi S KumarRachna ThakurBackground: Accurate root canal length determination, simplicity of the procedure, and patient's cooperation are important determinants in the success of endodontic treatment in primary teeth. Aim: The aim of the study was to clinically compare the accuracy of Propex Pixi and Formatron D10 apex locators with conventional radiography in determining working length in mandibular primary second molars with and without varying degrees of physiological root resorption. Design: A nonrandomized clinical trial was conducted in 115 mandibular primary second molars indicated for pulpectomy in 90 pediatric dental patients. A single calibrated examiner determined the working length by conventional radiographic method and electronic apex locator (EAL) methods in a total of 376 canals. Behavior of the children during execution of each method in each tooth was recorded using the Frankl's behavior rating scale. The data obtained were tabulated and subjected to statistical analysis. Results: Significant correlation (intraclass correlation = 0.80 and 0.81, P < 0.001) could be detected between working length measurements obtained using Propex Pixi and Formatron D10 and measurements obtained using conventional radiography. Higher percentage of negative behaviors (negative and definitely negative) was observed during the conventional radiographic method (68.6%) as opposed to the Propex Pixi (16.5%) and Formatron D10 (20.8%) methods. Conclusions: Both the apex locators were as accurate as conventional radiography in determining working length in primary teeth; Formatron D10 being more accurate than Propex Pixi. The EALs were far better accepted by children than conventional radiography.http://www.jisppd.com/article.asp?issn=0970-4388;year=2020;volume=38;issue=2;spage=158;epage=163;aulast=Nellamakkadaapex locatorbehaviorconventional radiographypulpectomyworking length
collection DOAJ
language English
format Article
sources DOAJ
author Krithi Nellamakkada
Sandya S Patil
Madhu Kakanur
Ravi S Kumar
Rachna Thakur
spellingShingle Krithi Nellamakkada
Sandya S Patil
Madhu Kakanur
Ravi S Kumar
Rachna Thakur
A clinical evaluation of two electronic apex locators and conventional radiography in working length determination in primary molar and its influence on children's behavioral responses
Journal of Indian Society of Pedodontics and Preventive Dentistry
apex locator
behavior
conventional radiography
pulpectomy
working length
author_facet Krithi Nellamakkada
Sandya S Patil
Madhu Kakanur
Ravi S Kumar
Rachna Thakur
author_sort Krithi Nellamakkada
title A clinical evaluation of two electronic apex locators and conventional radiography in working length determination in primary molar and its influence on children's behavioral responses
title_short A clinical evaluation of two electronic apex locators and conventional radiography in working length determination in primary molar and its influence on children's behavioral responses
title_full A clinical evaluation of two electronic apex locators and conventional radiography in working length determination in primary molar and its influence on children's behavioral responses
title_fullStr A clinical evaluation of two electronic apex locators and conventional radiography in working length determination in primary molar and its influence on children's behavioral responses
title_full_unstemmed A clinical evaluation of two electronic apex locators and conventional radiography in working length determination in primary molar and its influence on children's behavioral responses
title_sort clinical evaluation of two electronic apex locators and conventional radiography in working length determination in primary molar and its influence on children's behavioral responses
publisher Wolters Kluwer Medknow Publications
series Journal of Indian Society of Pedodontics and Preventive Dentistry
issn 0970-4388
1998-3905
publishDate 2020-01-01
description Background: Accurate root canal length determination, simplicity of the procedure, and patient's cooperation are important determinants in the success of endodontic treatment in primary teeth. Aim: The aim of the study was to clinically compare the accuracy of Propex Pixi and Formatron D10 apex locators with conventional radiography in determining working length in mandibular primary second molars with and without varying degrees of physiological root resorption. Design: A nonrandomized clinical trial was conducted in 115 mandibular primary second molars indicated for pulpectomy in 90 pediatric dental patients. A single calibrated examiner determined the working length by conventional radiographic method and electronic apex locator (EAL) methods in a total of 376 canals. Behavior of the children during execution of each method in each tooth was recorded using the Frankl's behavior rating scale. The data obtained were tabulated and subjected to statistical analysis. Results: Significant correlation (intraclass correlation = 0.80 and 0.81, P < 0.001) could be detected between working length measurements obtained using Propex Pixi and Formatron D10 and measurements obtained using conventional radiography. Higher percentage of negative behaviors (negative and definitely negative) was observed during the conventional radiographic method (68.6%) as opposed to the Propex Pixi (16.5%) and Formatron D10 (20.8%) methods. Conclusions: Both the apex locators were as accurate as conventional radiography in determining working length in primary teeth; Formatron D10 being more accurate than Propex Pixi. The EALs were far better accepted by children than conventional radiography.
topic apex locator
behavior
conventional radiography
pulpectomy
working length
url http://www.jisppd.com/article.asp?issn=0970-4388;year=2020;volume=38;issue=2;spage=158;epage=163;aulast=Nellamakkada
work_keys_str_mv AT krithinellamakkada aclinicalevaluationoftwoelectronicapexlocatorsandconventionalradiographyinworkinglengthdeterminationinprimarymolaranditsinfluenceonchildrensbehavioralresponses
AT sandyaspatil aclinicalevaluationoftwoelectronicapexlocatorsandconventionalradiographyinworkinglengthdeterminationinprimarymolaranditsinfluenceonchildrensbehavioralresponses
AT madhukakanur aclinicalevaluationoftwoelectronicapexlocatorsandconventionalradiographyinworkinglengthdeterminationinprimarymolaranditsinfluenceonchildrensbehavioralresponses
AT raviskumar aclinicalevaluationoftwoelectronicapexlocatorsandconventionalradiographyinworkinglengthdeterminationinprimarymolaranditsinfluenceonchildrensbehavioralresponses
AT rachnathakur aclinicalevaluationoftwoelectronicapexlocatorsandconventionalradiographyinworkinglengthdeterminationinprimarymolaranditsinfluenceonchildrensbehavioralresponses
AT krithinellamakkada clinicalevaluationoftwoelectronicapexlocatorsandconventionalradiographyinworkinglengthdeterminationinprimarymolaranditsinfluenceonchildrensbehavioralresponses
AT sandyaspatil clinicalevaluationoftwoelectronicapexlocatorsandconventionalradiographyinworkinglengthdeterminationinprimarymolaranditsinfluenceonchildrensbehavioralresponses
AT madhukakanur clinicalevaluationoftwoelectronicapexlocatorsandconventionalradiographyinworkinglengthdeterminationinprimarymolaranditsinfluenceonchildrensbehavioralresponses
AT raviskumar clinicalevaluationoftwoelectronicapexlocatorsandconventionalradiographyinworkinglengthdeterminationinprimarymolaranditsinfluenceonchildrensbehavioralresponses
AT rachnathakur clinicalevaluationoftwoelectronicapexlocatorsandconventionalradiographyinworkinglengthdeterminationinprimarymolaranditsinfluenceonchildrensbehavioralresponses
_version_ 1724701028257890304