Evaluation Method for Winding Performance of Distribution Transformer
In order to ensure the safe and stable operation of a power system, the performance evaluation of transformer windings after a short-circuit test can predict whether the windings are deformed in order to provide a useful reference for the operation and maintenance of the power sector. This paper pro...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-09-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/14/18/5832 |
id |
doaj-422b3a599ca34f2289bebf2f783be06b |
---|---|
record_format |
Article |
spelling |
doaj-422b3a599ca34f2289bebf2f783be06b2021-09-26T00:05:26ZengMDPI AGEnergies1996-10732021-09-01145832583210.3390/en14185832Evaluation Method for Winding Performance of Distribution TransformerChunguang Suo0Yanan Ren1Wenbin Zhang2Yincheng Li3Yanyun Wang4Yi Ke5College of Science, Kunming University of Science and Technology, Kunming 650504, ChinaCollege of Science, Kunming University of Science and Technology, Kunming 650504, ChinaCollege of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming 650504, ChinaCollege of Science, Kunming University of Science and Technology, Kunming 650504, ChinaCollege of Science, Kunming University of Science and Technology, Kunming 650504, ChinaCollege of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming 650504, ChinaIn order to ensure the safe and stable operation of a power system, the performance evaluation of transformer windings after a short-circuit test can predict whether the windings are deformed in order to provide a useful reference for the operation and maintenance of the power sector. This paper proposes a method for evaluating the performance of transformer windings in order to improve the overall effectiveness of a winding evaluation. The index data obtained based on a short-circuit impedance method, frequency response method, and oscillation wave method are used in the algorithm proposed in this paper. First, the transformer winding performance evaluation index system is constructed. Second, the weight of each index is determined by analytic hierarchy process, and then the fuzzy comprehensive assessment method is introduced, and the fuzzy evaluation matrix is established, the evaluation results are calculated using the evaluation formula. Finally, the maximum membership principle is used to determine the performance level of the transformer winding on the evaluation results, and the evaluation results of the transformer winding state are obtained. The example shows that the evaluation level of the measured transformer winding performance can be obtained by this method as “good”. Compared with the traditional method, this method can simplify the evaluation while maintaining higher accuracy.https://www.mdpi.com/1996-1073/14/18/5832short-circuit testtransformer windingperformanceevaluationanalytic hierarchy processfuzzy evaluation method |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Chunguang Suo Yanan Ren Wenbin Zhang Yincheng Li Yanyun Wang Yi Ke |
spellingShingle |
Chunguang Suo Yanan Ren Wenbin Zhang Yincheng Li Yanyun Wang Yi Ke Evaluation Method for Winding Performance of Distribution Transformer Energies short-circuit test transformer winding performance evaluation analytic hierarchy process fuzzy evaluation method |
author_facet |
Chunguang Suo Yanan Ren Wenbin Zhang Yincheng Li Yanyun Wang Yi Ke |
author_sort |
Chunguang Suo |
title |
Evaluation Method for Winding Performance of Distribution Transformer |
title_short |
Evaluation Method for Winding Performance of Distribution Transformer |
title_full |
Evaluation Method for Winding Performance of Distribution Transformer |
title_fullStr |
Evaluation Method for Winding Performance of Distribution Transformer |
title_full_unstemmed |
Evaluation Method for Winding Performance of Distribution Transformer |
title_sort |
evaluation method for winding performance of distribution transformer |
publisher |
MDPI AG |
series |
Energies |
issn |
1996-1073 |
publishDate |
2021-09-01 |
description |
In order to ensure the safe and stable operation of a power system, the performance evaluation of transformer windings after a short-circuit test can predict whether the windings are deformed in order to provide a useful reference for the operation and maintenance of the power sector. This paper proposes a method for evaluating the performance of transformer windings in order to improve the overall effectiveness of a winding evaluation. The index data obtained based on a short-circuit impedance method, frequency response method, and oscillation wave method are used in the algorithm proposed in this paper. First, the transformer winding performance evaluation index system is constructed. Second, the weight of each index is determined by analytic hierarchy process, and then the fuzzy comprehensive assessment method is introduced, and the fuzzy evaluation matrix is established, the evaluation results are calculated using the evaluation formula. Finally, the maximum membership principle is used to determine the performance level of the transformer winding on the evaluation results, and the evaluation results of the transformer winding state are obtained. The example shows that the evaluation level of the measured transformer winding performance can be obtained by this method as “good”. Compared with the traditional method, this method can simplify the evaluation while maintaining higher accuracy. |
topic |
short-circuit test transformer winding performance evaluation analytic hierarchy process fuzzy evaluation method |
url |
https://www.mdpi.com/1996-1073/14/18/5832 |
work_keys_str_mv |
AT chunguangsuo evaluationmethodforwindingperformanceofdistributiontransformer AT yananren evaluationmethodforwindingperformanceofdistributiontransformer AT wenbinzhang evaluationmethodforwindingperformanceofdistributiontransformer AT yinchengli evaluationmethodforwindingperformanceofdistributiontransformer AT yanyunwang evaluationmethodforwindingperformanceofdistributiontransformer AT yike evaluationmethodforwindingperformanceofdistributiontransformer |
_version_ |
1717367101968089088 |