Effects of liquid stimuli on dual-axis swallowing accelerometry signals in a healthy population

<p>Abstract</p> <p>Background</p> <p>Dual-axis swallowing accelerometry has recently been proposed as a tool for non-invasive analysis of swallowing function. Although swallowing is known to be physiologically modifiable by the type of food or liquid (i.e., stimuli), th...

Full description

Bibliographic Details
Main Authors: Sejdić Ervin, Lee Joon, Steele Catriona M, Chau Tom
Format: Article
Language:English
Published: BMC 2010-02-01
Series:BioMedical Engineering OnLine
Online Access:http://www.biomedical-engineering-online.com/content/9/1/7
id doaj-42ca9247c4e7440f8c367b8b4ba6cabb
record_format Article
spelling doaj-42ca9247c4e7440f8c367b8b4ba6cabb2020-11-25T00:38:28ZengBMCBioMedical Engineering OnLine1475-925X2010-02-0191710.1186/1475-925X-9-7Effects of liquid stimuli on dual-axis swallowing accelerometry signals in a healthy populationSejdić ErvinLee JoonSteele Catriona MChau Tom<p>Abstract</p> <p>Background</p> <p>Dual-axis swallowing accelerometry has recently been proposed as a tool for non-invasive analysis of swallowing function. Although swallowing is known to be physiologically modifiable by the type of food or liquid (i.e., stimuli), the effects of stimuli on dual-axis accelerometry signals have never been thoroughly investigated. Thus, the objective of this study was to investigate stimulus effects on dual-axis accelerometry signal characteristics. Signals were acquired from 17 healthy participants while swallowing 4 different stimuli: water, nectar-thick and honey-thick apple juices, and a thin-liquid barium suspension. Two swallowing tasks were examined: discrete and sequential. A variety of features were extracted in the time and time-frequency domains after swallow segmentation and pre-processing. A separate Friedman test was conducted for each feature and for each swallowing task.</p> <p>Results</p> <p>Significant main stimulus effects were found on 6 out of 30 features for the discrete task and on 5 out of 30 features for the sequential task. Analysis of the features with significant stimulus effects suggested that the changes in the signals revealed slower and more pronounced swallowing patterns with increasing bolus viscosity.</p> <p>Conclusions</p> <p>We conclude that stimulus type does affect specific characteristics of dual-axis swallowing accelerometry signals, suggesting that associated clinical screening protocols may need to be stimulus specific.</p> http://www.biomedical-engineering-online.com/content/9/1/7
collection DOAJ
language English
format Article
sources DOAJ
author Sejdić Ervin
Lee Joon
Steele Catriona M
Chau Tom
spellingShingle Sejdić Ervin
Lee Joon
Steele Catriona M
Chau Tom
Effects of liquid stimuli on dual-axis swallowing accelerometry signals in a healthy population
BioMedical Engineering OnLine
author_facet Sejdić Ervin
Lee Joon
Steele Catriona M
Chau Tom
author_sort Sejdić Ervin
title Effects of liquid stimuli on dual-axis swallowing accelerometry signals in a healthy population
title_short Effects of liquid stimuli on dual-axis swallowing accelerometry signals in a healthy population
title_full Effects of liquid stimuli on dual-axis swallowing accelerometry signals in a healthy population
title_fullStr Effects of liquid stimuli on dual-axis swallowing accelerometry signals in a healthy population
title_full_unstemmed Effects of liquid stimuli on dual-axis swallowing accelerometry signals in a healthy population
title_sort effects of liquid stimuli on dual-axis swallowing accelerometry signals in a healthy population
publisher BMC
series BioMedical Engineering OnLine
issn 1475-925X
publishDate 2010-02-01
description <p>Abstract</p> <p>Background</p> <p>Dual-axis swallowing accelerometry has recently been proposed as a tool for non-invasive analysis of swallowing function. Although swallowing is known to be physiologically modifiable by the type of food or liquid (i.e., stimuli), the effects of stimuli on dual-axis accelerometry signals have never been thoroughly investigated. Thus, the objective of this study was to investigate stimulus effects on dual-axis accelerometry signal characteristics. Signals were acquired from 17 healthy participants while swallowing 4 different stimuli: water, nectar-thick and honey-thick apple juices, and a thin-liquid barium suspension. Two swallowing tasks were examined: discrete and sequential. A variety of features were extracted in the time and time-frequency domains after swallow segmentation and pre-processing. A separate Friedman test was conducted for each feature and for each swallowing task.</p> <p>Results</p> <p>Significant main stimulus effects were found on 6 out of 30 features for the discrete task and on 5 out of 30 features for the sequential task. Analysis of the features with significant stimulus effects suggested that the changes in the signals revealed slower and more pronounced swallowing patterns with increasing bolus viscosity.</p> <p>Conclusions</p> <p>We conclude that stimulus type does affect specific characteristics of dual-axis swallowing accelerometry signals, suggesting that associated clinical screening protocols may need to be stimulus specific.</p>
url http://www.biomedical-engineering-online.com/content/9/1/7
work_keys_str_mv AT sejdicervin effectsofliquidstimuliondualaxisswallowingaccelerometrysignalsinahealthypopulation
AT leejoon effectsofliquidstimuliondualaxisswallowingaccelerometrysignalsinahealthypopulation
AT steelecatrionam effectsofliquidstimuliondualaxisswallowingaccelerometrysignalsinahealthypopulation
AT chautom effectsofliquidstimuliondualaxisswallowingaccelerometrysignalsinahealthypopulation
_version_ 1725297419055267840