A Guided Wave Sensor Enabling Simultaneous Wavenumber-Frequency Analysis for Both Lamb and Shear-Horizontal Waves

Guided waves in plate-like structures have been widely investigated for structural health monitoring. Lamb waves and shear horizontal (SH) waves, two commonly used types of waves in plates, provide different benefits for the detection of various types of defects and material degradation. However, th...

Full description

Bibliographic Details
Main Authors: Baiyang Ren, Hwanjeong Cho, Cliff J. Lissenden
Format: Article
Language:English
Published: MDPI AG 2017-03-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/17/3/488
id doaj-42e581e20f0249f783bab45c825c10dc
record_format Article
spelling doaj-42e581e20f0249f783bab45c825c10dc2020-11-24T21:12:37ZengMDPI AGSensors1424-82202017-03-0117348810.3390/s17030488s17030488A Guided Wave Sensor Enabling Simultaneous Wavenumber-Frequency Analysis for Both Lamb and Shear-Horizontal WavesBaiyang Ren0Hwanjeong Cho1Cliff J. Lissenden2Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USADepartment of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USADepartment of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USAGuided waves in plate-like structures have been widely investigated for structural health monitoring. Lamb waves and shear horizontal (SH) waves, two commonly used types of waves in plates, provide different benefits for the detection of various types of defects and material degradation. However, there are few sensors that can detect both Lamb and SH waves and also resolve their modal content, namely the wavenumber-frequency spectrum. A sensor that can detect both waves is desirable to take full advantage of both types of waves in order to improve sensitivity to different discontinuity geometries. We demonstrate that polyvinylidene difluoride (PVDF) film provides the basis for a multi-element array sensor that detects both Lamb and SH waves and also measures their modal content, i.e., the wavenumber-frequency spectrum.http://www.mdpi.com/1424-8220/17/3/488Lamb wavesshear horizontal waveswavenumber-frequency analysisPVDF sensor
collection DOAJ
language English
format Article
sources DOAJ
author Baiyang Ren
Hwanjeong Cho
Cliff J. Lissenden
spellingShingle Baiyang Ren
Hwanjeong Cho
Cliff J. Lissenden
A Guided Wave Sensor Enabling Simultaneous Wavenumber-Frequency Analysis for Both Lamb and Shear-Horizontal Waves
Sensors
Lamb waves
shear horizontal waves
wavenumber-frequency analysis
PVDF sensor
author_facet Baiyang Ren
Hwanjeong Cho
Cliff J. Lissenden
author_sort Baiyang Ren
title A Guided Wave Sensor Enabling Simultaneous Wavenumber-Frequency Analysis for Both Lamb and Shear-Horizontal Waves
title_short A Guided Wave Sensor Enabling Simultaneous Wavenumber-Frequency Analysis for Both Lamb and Shear-Horizontal Waves
title_full A Guided Wave Sensor Enabling Simultaneous Wavenumber-Frequency Analysis for Both Lamb and Shear-Horizontal Waves
title_fullStr A Guided Wave Sensor Enabling Simultaneous Wavenumber-Frequency Analysis for Both Lamb and Shear-Horizontal Waves
title_full_unstemmed A Guided Wave Sensor Enabling Simultaneous Wavenumber-Frequency Analysis for Both Lamb and Shear-Horizontal Waves
title_sort guided wave sensor enabling simultaneous wavenumber-frequency analysis for both lamb and shear-horizontal waves
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2017-03-01
description Guided waves in plate-like structures have been widely investigated for structural health monitoring. Lamb waves and shear horizontal (SH) waves, two commonly used types of waves in plates, provide different benefits for the detection of various types of defects and material degradation. However, there are few sensors that can detect both Lamb and SH waves and also resolve their modal content, namely the wavenumber-frequency spectrum. A sensor that can detect both waves is desirable to take full advantage of both types of waves in order to improve sensitivity to different discontinuity geometries. We demonstrate that polyvinylidene difluoride (PVDF) film provides the basis for a multi-element array sensor that detects both Lamb and SH waves and also measures their modal content, i.e., the wavenumber-frequency spectrum.
topic Lamb waves
shear horizontal waves
wavenumber-frequency analysis
PVDF sensor
url http://www.mdpi.com/1424-8220/17/3/488
work_keys_str_mv AT baiyangren aguidedwavesensorenablingsimultaneouswavenumberfrequencyanalysisforbothlambandshearhorizontalwaves
AT hwanjeongcho aguidedwavesensorenablingsimultaneouswavenumberfrequencyanalysisforbothlambandshearhorizontalwaves
AT cliffjlissenden aguidedwavesensorenablingsimultaneouswavenumberfrequencyanalysisforbothlambandshearhorizontalwaves
AT baiyangren guidedwavesensorenablingsimultaneouswavenumberfrequencyanalysisforbothlambandshearhorizontalwaves
AT hwanjeongcho guidedwavesensorenablingsimultaneouswavenumberfrequencyanalysisforbothlambandshearhorizontalwaves
AT cliffjlissenden guidedwavesensorenablingsimultaneouswavenumberfrequencyanalysisforbothlambandshearhorizontalwaves
_version_ 1716750410187800576