The Reliability of Transabdominal Cervical Length Measurement Compared with Transvaginal Measurement at 16-24 Weeks of Gestation

Objectives: To determine reliability of transabdominal cervical length (TACL) compared with transvaginal cervical length (TVCL) at 16-24 weeks of gestation. Materials and Methods: A prospective study was conducted in the Obstetrics and Gynecology Department at Phramongkutklao Hospital between 27 Ma...

Full description

Bibliographic Details
Main Authors: Nattaya Buathum, Peerapun Punpuckdeekoon, Nutthaphon Imsom-somboon
Format: Article
Language:English
Published: The Royal Thai College of Obstetricians and Gynaecologists 2019-09-01
Series:Thai Journal of Obstetrics and Gynaecology
Subjects:
Online Access:https://www.tci-thaijo.org/index.php/tjog/article/download/115977/142844/
id doaj-43d9f1f513c34507aa8d127533e82bda
record_format Article
spelling doaj-43d9f1f513c34507aa8d127533e82bda2020-11-25T00:09:21ZengThe Royal Thai College of Obstetricians and GynaecologistsThai Journal of Obstetrics and Gynaecology0857-60842019-09-01273165173https://doi.org/10.14456/tjog.2019.21The Reliability of Transabdominal Cervical Length Measurement Compared with Transvaginal Measurement at 16-24 Weeks of GestationNattaya Buathum0Peerapun Punpuckdeekoon1Nutthaphon Imsom-somboon2Department of Obstetrics and Gynecology, Phramongkutklao Hospital, Bangkok, ThailandDepartment of Obstetrics and Gynecology, Phramongkutklao Hospital, Bangkok, ThailandDepartment of Obstetrics and Gynecology, Phramongkutklao Hospital, Bangkok, ThailandObjectives: To determine reliability of transabdominal cervical length (TACL) compared with transvaginal cervical length (TVCL) at 16-24 weeks of gestation. Materials and Methods: A prospective study was conducted in the Obstetrics and Gynecology Department at Phramongkutklao Hospital between 27 March 2017 and 29 December 2017. Singleton pregnant women who underwent ultrasound between 16-24 weeks of gestation with any indication were enrolled. Women with a history of cervical surgery, uterine contractions and vaginal bleeding were excluded. After voiding, TACL was measured followed by TVCL as per the protocols stipulated by the Fetal Medicine Foundation (2014). Demographic and medical data were collected. Cervical length measurements from both methods were compared, and the factors accounting for differences in measured lengths were considered. Results: One hundred and forty-two women with singleton pregnancies agreed to participate in the study. Satisfactory TACL images could not be obtained within 5 min in 12 (8.6%) of the 142 women, and were excluded from the analysis. Of a total of 130 singleton pregnant women, mean TACL and TVCL values were found to be 39.3 ± 6.4 mm and 41.5 ± 7.4 mm, respectively. The mean TACL was found to be shorter than the mean TVCL by an average of 2.2 mm (p < 0.001). An intraclass correlation coefficient between both procedures was found to be 0.443 which was statistically significant (p < 0.001). Similarly, the difference between TVCL and TACL measurements decreased as BMI increased with statistical significance (p = 0.043). The 5th percentile of TACL and TVCL was 31 mm and 32 mm, respectively. None of the patients had a TACL and TVCL < 25 mm which is defined as a short cervix. Conclusion: The TACL assessment was possible to carry out 91.4% of pregnant women and was moderately correlated with TVCL, therefore, it may be considered as an initial screening tool for cervical length assessment in pregnant women at low-risk for preterm delivery.https://www.tci-thaijo.org/index.php/tjog/article/download/115977/142844/transabdominal cervical lengthtransvaginal cervical lengthpreterm deliveryreliabilitymeasurement
collection DOAJ
language English
format Article
sources DOAJ
author Nattaya Buathum
Peerapun Punpuckdeekoon
Nutthaphon Imsom-somboon
spellingShingle Nattaya Buathum
Peerapun Punpuckdeekoon
Nutthaphon Imsom-somboon
The Reliability of Transabdominal Cervical Length Measurement Compared with Transvaginal Measurement at 16-24 Weeks of Gestation
Thai Journal of Obstetrics and Gynaecology
transabdominal cervical length
transvaginal cervical length
preterm delivery
reliability
measurement
author_facet Nattaya Buathum
Peerapun Punpuckdeekoon
Nutthaphon Imsom-somboon
author_sort Nattaya Buathum
title The Reliability of Transabdominal Cervical Length Measurement Compared with Transvaginal Measurement at 16-24 Weeks of Gestation
title_short The Reliability of Transabdominal Cervical Length Measurement Compared with Transvaginal Measurement at 16-24 Weeks of Gestation
title_full The Reliability of Transabdominal Cervical Length Measurement Compared with Transvaginal Measurement at 16-24 Weeks of Gestation
title_fullStr The Reliability of Transabdominal Cervical Length Measurement Compared with Transvaginal Measurement at 16-24 Weeks of Gestation
title_full_unstemmed The Reliability of Transabdominal Cervical Length Measurement Compared with Transvaginal Measurement at 16-24 Weeks of Gestation
title_sort reliability of transabdominal cervical length measurement compared with transvaginal measurement at 16-24 weeks of gestation
publisher The Royal Thai College of Obstetricians and Gynaecologists
series Thai Journal of Obstetrics and Gynaecology
issn 0857-6084
publishDate 2019-09-01
description Objectives: To determine reliability of transabdominal cervical length (TACL) compared with transvaginal cervical length (TVCL) at 16-24 weeks of gestation. Materials and Methods: A prospective study was conducted in the Obstetrics and Gynecology Department at Phramongkutklao Hospital between 27 March 2017 and 29 December 2017. Singleton pregnant women who underwent ultrasound between 16-24 weeks of gestation with any indication were enrolled. Women with a history of cervical surgery, uterine contractions and vaginal bleeding were excluded. After voiding, TACL was measured followed by TVCL as per the protocols stipulated by the Fetal Medicine Foundation (2014). Demographic and medical data were collected. Cervical length measurements from both methods were compared, and the factors accounting for differences in measured lengths were considered. Results: One hundred and forty-two women with singleton pregnancies agreed to participate in the study. Satisfactory TACL images could not be obtained within 5 min in 12 (8.6%) of the 142 women, and were excluded from the analysis. Of a total of 130 singleton pregnant women, mean TACL and TVCL values were found to be 39.3 ± 6.4 mm and 41.5 ± 7.4 mm, respectively. The mean TACL was found to be shorter than the mean TVCL by an average of 2.2 mm (p < 0.001). An intraclass correlation coefficient between both procedures was found to be 0.443 which was statistically significant (p < 0.001). Similarly, the difference between TVCL and TACL measurements decreased as BMI increased with statistical significance (p = 0.043). The 5th percentile of TACL and TVCL was 31 mm and 32 mm, respectively. None of the patients had a TACL and TVCL < 25 mm which is defined as a short cervix. Conclusion: The TACL assessment was possible to carry out 91.4% of pregnant women and was moderately correlated with TVCL, therefore, it may be considered as an initial screening tool for cervical length assessment in pregnant women at low-risk for preterm delivery.
topic transabdominal cervical length
transvaginal cervical length
preterm delivery
reliability
measurement
url https://www.tci-thaijo.org/index.php/tjog/article/download/115977/142844/
work_keys_str_mv AT nattayabuathum thereliabilityoftransabdominalcervicallengthmeasurementcomparedwithtransvaginalmeasurementat1624weeksofgestation
AT peerapunpunpuckdeekoon thereliabilityoftransabdominalcervicallengthmeasurementcomparedwithtransvaginalmeasurementat1624weeksofgestation
AT nutthaphonimsomsomboon thereliabilityoftransabdominalcervicallengthmeasurementcomparedwithtransvaginalmeasurementat1624weeksofgestation
AT nattayabuathum reliabilityoftransabdominalcervicallengthmeasurementcomparedwithtransvaginalmeasurementat1624weeksofgestation
AT peerapunpunpuckdeekoon reliabilityoftransabdominalcervicallengthmeasurementcomparedwithtransvaginalmeasurementat1624weeksofgestation
AT nutthaphonimsomsomboon reliabilityoftransabdominalcervicallengthmeasurementcomparedwithtransvaginalmeasurementat1624weeksofgestation
_version_ 1725412435164135424