TUNING CONTROLLER BY ZIEGLER AND NICHOLS METHOD TO SPECIFICATION TOP PRODUCT OF A DISTILLATION COLUMN

This article seeks to find the tuning for a driver for the product specification of the top of a distillation column, in order to keep the product always in the desired specification  range and can generate great savings for the process. He carried out the approach system in a first order transfer f...

Full description

Bibliographic Details
Main Author: Eduardo Ramos Braga
Format: Article
Language:English
Published: Universidade Federal de Viçosa (UFV) 2016-05-01
Series:The Journal of Engineering and Exact Sciences
Subjects:
Online Access:https://periodicos.ufv.br/ojs/jcec/article/view/2171
id doaj-46830a28d01a461eadd3e340185a11d3
record_format Article
spelling doaj-46830a28d01a461eadd3e340185a11d32020-11-24T21:54:52ZengUniversidade Federal de Viçosa (UFV)The Journal of Engineering and Exact Sciences2527-10752016-05-012304706010.18540/jcecvl2iss3pp047-060833TUNING CONTROLLER BY ZIEGLER AND NICHOLS METHOD TO SPECIFICATION TOP PRODUCT OF A DISTILLATION COLUMNEduardo Ramos Braga0Universidade Salvador (UNIFACS)This article seeks to find the tuning for a driver for the product specification of the top of a distillation column, in order to keep the product always in the desired specification  range and can generate great savings for the process. He carried out the approach system in a first order transfer function with the aid of the simulator ControlStation 3.5 and Excel. After we met the open loop parameters such as Kp (process gain), T (time constant) minutes and Θ (delay constant). Subsequently, he selected the PID controller as it is indicated to slow processes and / or who do not wish residual errors and many swings. It analyzed three cases: The variation of the disturbance variable, the variation of the set value (SP) and the start of the process. For all of them the driver parameters were determined by Ziegler and Nichols tuning method in open loop, getting a Kc (controller gain) value of 3,957, a Ti (integration time) of 16 minutes and Td (time derivation) of 4 minutes. It was noted then that in both cases, the valuesfound in this line met all the pre-established criteria. Finally, we compared the results obtained by Ziegler and Nichols tuning with the other tuning methods, which further evidenced its efficiency.https://periodicos.ufv.br/ojs/jcec/article/view/2171SintoniaControladorParâmetrosEspecificaçãoTempo.
collection DOAJ
language English
format Article
sources DOAJ
author Eduardo Ramos Braga
spellingShingle Eduardo Ramos Braga
TUNING CONTROLLER BY ZIEGLER AND NICHOLS METHOD TO SPECIFICATION TOP PRODUCT OF A DISTILLATION COLUMN
The Journal of Engineering and Exact Sciences
Sintonia
Controlador
Parâmetros
Especificação
Tempo.
author_facet Eduardo Ramos Braga
author_sort Eduardo Ramos Braga
title TUNING CONTROLLER BY ZIEGLER AND NICHOLS METHOD TO SPECIFICATION TOP PRODUCT OF A DISTILLATION COLUMN
title_short TUNING CONTROLLER BY ZIEGLER AND NICHOLS METHOD TO SPECIFICATION TOP PRODUCT OF A DISTILLATION COLUMN
title_full TUNING CONTROLLER BY ZIEGLER AND NICHOLS METHOD TO SPECIFICATION TOP PRODUCT OF A DISTILLATION COLUMN
title_fullStr TUNING CONTROLLER BY ZIEGLER AND NICHOLS METHOD TO SPECIFICATION TOP PRODUCT OF A DISTILLATION COLUMN
title_full_unstemmed TUNING CONTROLLER BY ZIEGLER AND NICHOLS METHOD TO SPECIFICATION TOP PRODUCT OF A DISTILLATION COLUMN
title_sort tuning controller by ziegler and nichols method to specification top product of a distillation column
publisher Universidade Federal de Viçosa (UFV)
series The Journal of Engineering and Exact Sciences
issn 2527-1075
publishDate 2016-05-01
description This article seeks to find the tuning for a driver for the product specification of the top of a distillation column, in order to keep the product always in the desired specification  range and can generate great savings for the process. He carried out the approach system in a first order transfer function with the aid of the simulator ControlStation 3.5 and Excel. After we met the open loop parameters such as Kp (process gain), T (time constant) minutes and Θ (delay constant). Subsequently, he selected the PID controller as it is indicated to slow processes and / or who do not wish residual errors and many swings. It analyzed three cases: The variation of the disturbance variable, the variation of the set value (SP) and the start of the process. For all of them the driver parameters were determined by Ziegler and Nichols tuning method in open loop, getting a Kc (controller gain) value of 3,957, a Ti (integration time) of 16 minutes and Td (time derivation) of 4 minutes. It was noted then that in both cases, the valuesfound in this line met all the pre-established criteria. Finally, we compared the results obtained by Ziegler and Nichols tuning with the other tuning methods, which further evidenced its efficiency.
topic Sintonia
Controlador
Parâmetros
Especificação
Tempo.
url https://periodicos.ufv.br/ojs/jcec/article/view/2171
work_keys_str_mv AT eduardoramosbraga tuningcontrollerbyzieglerandnicholsmethodtospecificationtopproductofadistillationcolumn
_version_ 1725865184165101568