Deployment of a Covered Stent for Left Internal Mammary Perforation From Percutaneous Pacemaker ImplantationNovel Teaching Points
A 79-year-old woman developed a hemothorax 2 days after implantation of a permanent pacemaker. Computed tomography angiography revealed active extravasation from the left internal mammary artery. A covered stent was deployed to manage the arterial perforation. This case report explores different ven...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2020-11-01
|
Series: | CJC Open |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2589790X20301001 |
id |
doaj-471ea14241ba4a91adf67b987c3782dc |
---|---|
record_format |
Article |
spelling |
doaj-471ea14241ba4a91adf67b987c3782dc2020-12-01T04:06:11ZengElsevierCJC Open2589-790X2020-11-0126708710Deployment of a Covered Stent for Left Internal Mammary Perforation From Percutaneous Pacemaker ImplantationNovel Teaching PointsKaren Ho, MD0Rajesh Patel, MD, FRCPC1Payam Dehghani, MD, FRCPC2Division of Internal Medicine, University of Saskatchewan College of Medicine, Saskatoon, Saskatchewan, Canada; Corresponding author: Dr Karen Ho, Department of Cardioneurosciences, 3rd Floor, Regina General Hospital, 1440 14th Avenue, Regina, SK, S4P 0W5, Canada. Tel.: +1-306-596-9799.Department of Medical Imaging, Reginal Qu’Appelle Health Region, Saskatchewan, CanadaDivision of Internal Medicine, University of Saskatchewan College of Medicine, Saskatoon, Saskatchewan, Canada; Section of Cardiology, Department of Internal Medicine, Regina General Hospital, Regina, Saskatchewan, CanadaA 79-year-old woman developed a hemothorax 2 days after implantation of a permanent pacemaker. Computed tomography angiography revealed active extravasation from the left internal mammary artery. A covered stent was deployed to manage the arterial perforation. This case report explores different venous access techniques to minimize the risk of arterial injuries and describes the use of a covered stent in managing a non-grafted left internal mammary artery injury from a pacemaker implantation procedure. Résumé: Une femme de 79 ans a présenté un hémothorax deux jours après l’implantation d’un stimulateur cardiaque permanent. Une angiographie par tomodensitométrie a mis en évidence une extravasation active à partir de l’artère mammaire interne gauche. Une endoprothèse couverte a été déployée pour la prise en charge de la perforation artérielle. Ce cas porte sur l’utilisation de diverses techniques d’accès veineux pour réduire au minimum le risque de lésions artérielles, et décrit l’utilisation d’une endoprothèse couverte pour la prise en charge d’une lésion de l’artère mammaire interne gauche non greffée découlant de l’implantation d’un stimulateur cardiaque.http://www.sciencedirect.com/science/article/pii/S2589790X20301001 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Karen Ho, MD Rajesh Patel, MD, FRCPC Payam Dehghani, MD, FRCPC |
spellingShingle |
Karen Ho, MD Rajesh Patel, MD, FRCPC Payam Dehghani, MD, FRCPC Deployment of a Covered Stent for Left Internal Mammary Perforation From Percutaneous Pacemaker ImplantationNovel Teaching Points CJC Open |
author_facet |
Karen Ho, MD Rajesh Patel, MD, FRCPC Payam Dehghani, MD, FRCPC |
author_sort |
Karen Ho, MD |
title |
Deployment of a Covered Stent for Left Internal Mammary Perforation From Percutaneous Pacemaker ImplantationNovel Teaching Points |
title_short |
Deployment of a Covered Stent for Left Internal Mammary Perforation From Percutaneous Pacemaker ImplantationNovel Teaching Points |
title_full |
Deployment of a Covered Stent for Left Internal Mammary Perforation From Percutaneous Pacemaker ImplantationNovel Teaching Points |
title_fullStr |
Deployment of a Covered Stent for Left Internal Mammary Perforation From Percutaneous Pacemaker ImplantationNovel Teaching Points |
title_full_unstemmed |
Deployment of a Covered Stent for Left Internal Mammary Perforation From Percutaneous Pacemaker ImplantationNovel Teaching Points |
title_sort |
deployment of a covered stent for left internal mammary perforation from percutaneous pacemaker implantationnovel teaching points |
publisher |
Elsevier |
series |
CJC Open |
issn |
2589-790X |
publishDate |
2020-11-01 |
description |
A 79-year-old woman developed a hemothorax 2 days after implantation of a permanent pacemaker. Computed tomography angiography revealed active extravasation from the left internal mammary artery. A covered stent was deployed to manage the arterial perforation. This case report explores different venous access techniques to minimize the risk of arterial injuries and describes the use of a covered stent in managing a non-grafted left internal mammary artery injury from a pacemaker implantation procedure. Résumé: Une femme de 79 ans a présenté un hémothorax deux jours après l’implantation d’un stimulateur cardiaque permanent. Une angiographie par tomodensitométrie a mis en évidence une extravasation active à partir de l’artère mammaire interne gauche. Une endoprothèse couverte a été déployée pour la prise en charge de la perforation artérielle. Ce cas porte sur l’utilisation de diverses techniques d’accès veineux pour réduire au minimum le risque de lésions artérielles, et décrit l’utilisation d’une endoprothèse couverte pour la prise en charge d’une lésion de l’artère mammaire interne gauche non greffée découlant de l’implantation d’un stimulateur cardiaque. |
url |
http://www.sciencedirect.com/science/article/pii/S2589790X20301001 |
work_keys_str_mv |
AT karenhomd deploymentofacoveredstentforleftinternalmammaryperforationfrompercutaneouspacemakerimplantationnovelteachingpoints AT rajeshpatelmdfrcpc deploymentofacoveredstentforleftinternalmammaryperforationfrompercutaneouspacemakerimplantationnovelteachingpoints AT payamdehghanimdfrcpc deploymentofacoveredstentforleftinternalmammaryperforationfrompercutaneouspacemakerimplantationnovelteachingpoints |
_version_ |
1724411059383566336 |