Corrosion and wettability of PEO coatings on magnesium by addition of potassium stearate
Hydrophobic PEO coatings were fabricated in an electrolyte containing potassium stearate. The wetting behaviour of coated samples was studied using dynamic and static contact angle. Also, the corrosion behaviour of the samples was evaluated by polarization method. The dynamic contact angle and hyste...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
KeAi Communications Co., Ltd.
2017-06-01
|
Series: | Journal of Magnesium and Alloys |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2213956717300245 |
id |
doaj-47cdd59ef6f3494d8d63c6f161864e9f |
---|---|
record_format |
Article |
spelling |
doaj-47cdd59ef6f3494d8d63c6f161864e9f2021-02-02T07:11:40ZengKeAi Communications Co., Ltd.Journal of Magnesium and Alloys2213-95672017-06-0152210216Corrosion and wettability of PEO coatings on magnesium by addition of potassium stearateS.S. Farhadi0M. Aliofkhazraei1Gh. Barati Darband2A. Abolhasani3A. Sabour Rouhaghdam4Department of Materials Science, Faculty of Engineering, Tarbiat Modares University, P.O.Box: 14115-143, Tehran, IranCorresponding author. Department of Materials Science, Faculty of Engineering, Tarbiat Modares University, P.O. Box: 14115-143, Tehran, Iran.; Department of Materials Science, Faculty of Engineering, Tarbiat Modares University, P.O.Box: 14115-143, Tehran, IranDepartment of Materials Science, Faculty of Engineering, Tarbiat Modares University, P.O.Box: 14115-143, Tehran, IranDepartment of Materials Science, Faculty of Engineering, Tarbiat Modares University, P.O.Box: 14115-143, Tehran, IranDepartment of Materials Science, Faculty of Engineering, Tarbiat Modares University, P.O.Box: 14115-143, Tehran, IranHydrophobic PEO coatings were fabricated in an electrolyte containing potassium stearate. The wetting behaviour of coated samples was studied using dynamic and static contact angle. Also, the corrosion behaviour of the samples was evaluated by polarization method. The dynamic contact angle and hysteresis of the contact angle for PEO coating were evaluated by Wilhelmy plate method. There was an increase in the contact angle of the nanocomposite and traditional PEO coatings when potassium stearate was added to the electrolyte up to 130°. The more hydrophobic coatings, showed more corrosion resistance in 3.5 wt.% NaCl solution. The synergistic effect of potassium stearate and nanoparticles increased the hydrophobicity because of assembling of fatty acid on ceramic powder. Keywords: Magnesium, Coatings, Wilhelmy plate, Plasma electrolytic oxidation, Corrosionhttp://www.sciencedirect.com/science/article/pii/S2213956717300245 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
S.S. Farhadi M. Aliofkhazraei Gh. Barati Darband A. Abolhasani A. Sabour Rouhaghdam |
spellingShingle |
S.S. Farhadi M. Aliofkhazraei Gh. Barati Darband A. Abolhasani A. Sabour Rouhaghdam Corrosion and wettability of PEO coatings on magnesium by addition of potassium stearate Journal of Magnesium and Alloys |
author_facet |
S.S. Farhadi M. Aliofkhazraei Gh. Barati Darband A. Abolhasani A. Sabour Rouhaghdam |
author_sort |
S.S. Farhadi |
title |
Corrosion and wettability of PEO coatings on magnesium by addition of potassium stearate |
title_short |
Corrosion and wettability of PEO coatings on magnesium by addition of potassium stearate |
title_full |
Corrosion and wettability of PEO coatings on magnesium by addition of potassium stearate |
title_fullStr |
Corrosion and wettability of PEO coatings on magnesium by addition of potassium stearate |
title_full_unstemmed |
Corrosion and wettability of PEO coatings on magnesium by addition of potassium stearate |
title_sort |
corrosion and wettability of peo coatings on magnesium by addition of potassium stearate |
publisher |
KeAi Communications Co., Ltd. |
series |
Journal of Magnesium and Alloys |
issn |
2213-9567 |
publishDate |
2017-06-01 |
description |
Hydrophobic PEO coatings were fabricated in an electrolyte containing potassium stearate. The wetting behaviour of coated samples was studied using dynamic and static contact angle. Also, the corrosion behaviour of the samples was evaluated by polarization method. The dynamic contact angle and hysteresis of the contact angle for PEO coating were evaluated by Wilhelmy plate method. There was an increase in the contact angle of the nanocomposite and traditional PEO coatings when potassium stearate was added to the electrolyte up to 130°. The more hydrophobic coatings, showed more corrosion resistance in 3.5 wt.% NaCl solution. The synergistic effect of potassium stearate and nanoparticles increased the hydrophobicity because of assembling of fatty acid on ceramic powder. Keywords: Magnesium, Coatings, Wilhelmy plate, Plasma electrolytic oxidation, Corrosion |
url |
http://www.sciencedirect.com/science/article/pii/S2213956717300245 |
work_keys_str_mv |
AT ssfarhadi corrosionandwettabilityofpeocoatingsonmagnesiumbyadditionofpotassiumstearate AT maliofkhazraei corrosionandwettabilityofpeocoatingsonmagnesiumbyadditionofpotassiumstearate AT ghbaratidarband corrosionandwettabilityofpeocoatingsonmagnesiumbyadditionofpotassiumstearate AT aabolhasani corrosionandwettabilityofpeocoatingsonmagnesiumbyadditionofpotassiumstearate AT asabourrouhaghdam corrosionandwettabilityofpeocoatingsonmagnesiumbyadditionofpotassiumstearate |
_version_ |
1724299883545886720 |