Comparative analysis of the SpinoMeter mobile application and Surgimap system for measuring the sagittal balance parameters: inter-observer reliability test

The purpose of the study was to assess the reliability, accuracy and effectiveness of a mobile application SpinoMeter for measuring the sagittal balance of the spino-pelvic complex in comparison with the desktop preoperative planning system Surgimap. Methods SpinoMeter mobile application was develo...

Full description

Bibliographic Details
Main Authors: Dmitry V. Ivanov, Irina V. Kirillova, Leonid Yu. Kossovich, Sergei V. Likhachev, Asel V. Polienko, Alexander V. Kharlamov, Alexei E. Shulga
Format: Article
Language:English
Published: Russian Ilizarov Scientific Center for Restorative Traumatology and Orthopaedics 2021-02-01
Series:Гений oртопедии
Subjects:
id doaj-481e79a177b14cb991c21ad17ef59e8c
record_format Article
spelling doaj-481e79a177b14cb991c21ad17ef59e8c2021-02-17T04:22:27ZengRussian Ilizarov Scientific Center for Restorative Traumatology and OrthopaedicsГений oртопедии1028-44272542-131X2021-02-01271747910.18019/1028-4427-2021-27-1-74-79Comparative analysis of the SpinoMeter mobile application and Surgimap system for measuring the sagittal balance parameters: inter-observer reliability testDmitry V. Ivanov0Irina V. Kirillova1Leonid Yu. Kossovich2Sergei V. Likhachev3Asel V. Polienko4Alexander V. Kharlamov5Alexei E. Shulga6Saratov State Medical University named after V.I. Razumovsky, Saratov, Russian FederationSaratov State Medical University named after V.I. Razumovsky, Saratov, Russian FederationSaratov State Medical University named after V.I. Razumovsky, Saratov, Russian FederationSaratov State University, Saratov, Russian FederationSaratov State Medical University named after V.I. Razumovsky, Saratov, Russian FederationSaratov State Medical University named after V.I. Razumovsky, Saratov, Russian FederationSaratov State University, Saratov, Russian FederationThe purpose of the study was to assess the reliability, accuracy and effectiveness of a mobile application SpinoMeter for measuring the sagittal balance of the spino-pelvic complex in comparison with the desktop preoperative planning system Surgimap. Methods SpinoMeter mobile application was developed in 2019 at the laboratory for Medical Decision Support Systems of Saratov State University. SpinoMeter is intended for measuring the actual and for calculating the optimal parameters of the sagittal balance of the spino-pelvic complex of a particular patient. Pelvic incidence (PI), lumbar lordosis (LL), sacral slope (SS) and pelvic tilt (PT) were measured with the help of Surgimap and SpinoMeter. Inter-observer reliability was assessed on X-rays in a standing position of 52 patients having consequences of injuries and pathology of the lumbar spine with imbalance syndrome. The research site was the Scientific Research Institute of Traumatology, Orthopedics and Neurosurgery of Saratov State Medical University. Measurements of the sagittal balance parameters were presented in tables and diagrams. For all data, the hypothesis of a normal distribution of the measurement results was tested using the Kolmogorov-Smirnov test. To test the hypothesis of homogeneity of the measurement results for normally distributed samples, the paired Student t-test was used. In the absence of a normal distribution, the Wilcoxon test was used for related samples. Results For PI, PT, SS and L1-S1 lordosis at a significance level of 5 %, the hypothesis of uniformity of measurements was confirmed. The average value of L4-S1 lordosis, measured by SpinoMeter, was shifted down relative to the measurements of this parameter by the Surgimap program. The shift did not exceed 0.7 %. Conclusion SpinoMeter mobile application is equivalent to the Surgimap system in terms of measuring the sagittal balance parameters based on radiographs in a standing position.sagittal balancemobile applicationsagittal balance parameters
collection DOAJ
language English
format Article
sources DOAJ
author Dmitry V. Ivanov
Irina V. Kirillova
Leonid Yu. Kossovich
Sergei V. Likhachev
Asel V. Polienko
Alexander V. Kharlamov
Alexei E. Shulga
spellingShingle Dmitry V. Ivanov
Irina V. Kirillova
Leonid Yu. Kossovich
Sergei V. Likhachev
Asel V. Polienko
Alexander V. Kharlamov
Alexei E. Shulga
Comparative analysis of the SpinoMeter mobile application and Surgimap system for measuring the sagittal balance parameters: inter-observer reliability test
Гений oртопедии
sagittal balance
mobile application
sagittal balance parameters
author_facet Dmitry V. Ivanov
Irina V. Kirillova
Leonid Yu. Kossovich
Sergei V. Likhachev
Asel V. Polienko
Alexander V. Kharlamov
Alexei E. Shulga
author_sort Dmitry V. Ivanov
title Comparative analysis of the SpinoMeter mobile application and Surgimap system for measuring the sagittal balance parameters: inter-observer reliability test
title_short Comparative analysis of the SpinoMeter mobile application and Surgimap system for measuring the sagittal balance parameters: inter-observer reliability test
title_full Comparative analysis of the SpinoMeter mobile application and Surgimap system for measuring the sagittal balance parameters: inter-observer reliability test
title_fullStr Comparative analysis of the SpinoMeter mobile application and Surgimap system for measuring the sagittal balance parameters: inter-observer reliability test
title_full_unstemmed Comparative analysis of the SpinoMeter mobile application and Surgimap system for measuring the sagittal balance parameters: inter-observer reliability test
title_sort comparative analysis of the spinometer mobile application and surgimap system for measuring the sagittal balance parameters: inter-observer reliability test
publisher Russian Ilizarov Scientific Center for Restorative Traumatology and Orthopaedics
series Гений oртопедии
issn 1028-4427
2542-131X
publishDate 2021-02-01
description The purpose of the study was to assess the reliability, accuracy and effectiveness of a mobile application SpinoMeter for measuring the sagittal balance of the spino-pelvic complex in comparison with the desktop preoperative planning system Surgimap. Methods SpinoMeter mobile application was developed in 2019 at the laboratory for Medical Decision Support Systems of Saratov State University. SpinoMeter is intended for measuring the actual and for calculating the optimal parameters of the sagittal balance of the spino-pelvic complex of a particular patient. Pelvic incidence (PI), lumbar lordosis (LL), sacral slope (SS) and pelvic tilt (PT) were measured with the help of Surgimap and SpinoMeter. Inter-observer reliability was assessed on X-rays in a standing position of 52 patients having consequences of injuries and pathology of the lumbar spine with imbalance syndrome. The research site was the Scientific Research Institute of Traumatology, Orthopedics and Neurosurgery of Saratov State Medical University. Measurements of the sagittal balance parameters were presented in tables and diagrams. For all data, the hypothesis of a normal distribution of the measurement results was tested using the Kolmogorov-Smirnov test. To test the hypothesis of homogeneity of the measurement results for normally distributed samples, the paired Student t-test was used. In the absence of a normal distribution, the Wilcoxon test was used for related samples. Results For PI, PT, SS and L1-S1 lordosis at a significance level of 5 %, the hypothesis of uniformity of measurements was confirmed. The average value of L4-S1 lordosis, measured by SpinoMeter, was shifted down relative to the measurements of this parameter by the Surgimap program. The shift did not exceed 0.7 %. Conclusion SpinoMeter mobile application is equivalent to the Surgimap system in terms of measuring the sagittal balance parameters based on radiographs in a standing position.
topic sagittal balance
mobile application
sagittal balance parameters
work_keys_str_mv AT dmitryvivanov comparativeanalysisofthespinometermobileapplicationandsurgimapsystemformeasuringthesagittalbalanceparametersinterobserverreliabilitytest
AT irinavkirillova comparativeanalysisofthespinometermobileapplicationandsurgimapsystemformeasuringthesagittalbalanceparametersinterobserverreliabilitytest
AT leonidyukossovich comparativeanalysisofthespinometermobileapplicationandsurgimapsystemformeasuringthesagittalbalanceparametersinterobserverreliabilitytest
AT sergeivlikhachev comparativeanalysisofthespinometermobileapplicationandsurgimapsystemformeasuringthesagittalbalanceparametersinterobserverreliabilitytest
AT aselvpolienko comparativeanalysisofthespinometermobileapplicationandsurgimapsystemformeasuringthesagittalbalanceparametersinterobserverreliabilitytest
AT alexandervkharlamov comparativeanalysisofthespinometermobileapplicationandsurgimapsystemformeasuringthesagittalbalanceparametersinterobserverreliabilitytest
AT alexeieshulga comparativeanalysisofthespinometermobileapplicationandsurgimapsystemformeasuringthesagittalbalanceparametersinterobserverreliabilitytest
_version_ 1724265548267651072