Misinsertion of central venous catheter into the suspected vertebral vein: a case report

We experienced a case in which a central venous catheter (CVC) was misplaced into the wrong vein, which was mistaken for the internal jugular vein (IJV), identified by chest x-ray and ultrasound. The vertebral vein passes through the transverse foramina from the atlas to the 6th cervical vertebra. A...

Full description

Bibliographic Details
Main Authors: So-Hee Yang, Sung-Mee Jung, Sang-Jin Park
Format: Article
Language:English
Published: Korean Society of Anesthesiologists 2014-11-01
Series:Korean Journal of Anesthesiology
Subjects:
Online Access:http://ekja.org/upload/pdf/kjae-67-342.pdf
Description
Summary:We experienced a case in which a central venous catheter (CVC) was misplaced into the wrong vein, which was mistaken for the internal jugular vein (IJV), identified by chest x-ray and ultrasound. The vertebral vein passes through the transverse foramina from the atlas to the 6th cervical vertebra. After exiting the transverse foramen of the 6th vertebra, the vein subsequently runs anterolateral to the vertebral artery and posterior to the IJV and drains the innominate vein. In this case, chest x-ray and ultrasound revealed that the inserted CVC had a course very similar to the vertebral vein. The misplacement of a CVC into the vertebral vein might occur from excessive rotation of the patient's head, which leads to alterations in the cervical vascular anatomy, and from deep insertion of the puncture needle. Therefore, it is advised, for safe CVC insertion, to minimize a patient's head rotation and to make use of ultrasound when the anatomical structures cannot be clearly identified.
ISSN:2005-6419
2005-7563